Airborne transmission is an important mechanism of spread for both viruses and bacteria in hospitals, with nosocomial infections putting a great burden on public health. In this study, we designed and manufactured a bed for pediatric clinic consultation rooms providing air isolation to protect patients and medical personnel from pathogen transmission. The pediatric isolation bed has several primary efficiency filters and a high-efficiency particulate air filter in the bedside unit. The air circulation between inlet and outlet forms negative pressure to remove the patient’s exhaled air timeously and effectively. A computational fluid dynamics model was used to calculate the speed of the airflow and the angle of sampler. Following this, we conducted purification experiments using cigarette smoke, Staphylococcus albus (S. albus) and human adenovirus type 5 (HAdV-5) to demonstrate the isolation efficacy. The results showed that the patient’s head should be placed as close to the air inlet hood as possible, and an air intake wind speed of 0.86 m/s was effective. The isolation efficacy of the pediatric isolation bed was demonstrated by computational fluid dynamics technology. The isolation efficiency against cigarette smoke exceeded 91.8%, and against S. albus was greater than 99.8%, while the isolation efficiency against HAdV-5 was 100%. The pediatric isolation bed could be used where isolation wards are unavailable, such as in intensive care units and primary clinical settings, to control hospital acquired infections.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Abbreviations
- CFD:
-
computational fluid dynamics
- S. albus :
-
Staphylococcus albus
- HAdV-5:
-
human adenovirus type 5
- NI:
-
nosocomial infection
- PI:
-
pediatric isolation
References
Ai Z, Hashimoto K, Melikov AK (2019). Airborne transmission between room occupants during short-term events: Measurement and evaluation. Indoor Air, 29: 563–576.
Alsved ML, Fraenkel C-J, Bohgard M, et al. (2019). Sources of airborne norovirus in hospital outbreaks. Clinical Infectious Diseases, 70: 2023–2028.
Bertran K, Balzli C, Kwon YK, et al. (2017). Airborne transmission of highly pathogenic influenza virus during processing of infected poultry. Emerging Infectious Diseases, 23: 1806–1814.
Carlos W, Cruz CSD, Cao B, et al. (2020). COVID-19 disease due to SARS-CoV-2 (novel coronavirus). American Journal of Respiratory and Critical Care Medicine, 201(4): 7–8.
Fujiyoshi S, Tanaka D, Maruyama F (2017). Transmission of airborne bacteria across built environments and its measurement standards: A review. Frontiers Microbiology, 8: 2336.
Goscé L, Johansson A (2018). Analysing the link between public transport use and airborne transmission: mobility and contagion in the London underground. Environmental Health, 17: 84.
Guo Z-D, Wang Z-Y, Zhang S-F, et al. (2020). Aerosol and surface distribution of severe acute respiratory syndrome coronavirus 2 in hospital wards, Wuhan, China, 2020. Emerging Infectious Diseases, 26: 1583–1591.
Hella J, Morrow C, Mhimbira F, et al. (2017). Tuberculosis transmission in public locations in Tanzania: A novel approach to studying airborne disease transmission. Journal of Infection, 75: 191–197.
Ji Y, Qian H, Ye J, et al. (2018). The impact of ambient humidity on the evaporation and dispersion of exhaled breathing droplets: A numerical investigation. Journal of Aerosol Science, 115: 164–172.
Jiang Y, Wang H, Chen Y, et al. (2020). Clinical Data on hospital environmental hygiene monitoring and medical staff protection during the coronavirus disease 2019 outbreak. medRxiv 2020.02.25.20028043.
Lanzerstorfer A, Hackl M, Schlömer M, et al. (2019). The influence of air-dispersed essential oils from lemon (Citrus Limon) and silver fir (Abies alba) on airborne bacteria and fungi in hospital rooms. Journal of Environmental Science and Health, Part A, 54: 256–260.
Liu T, Zhou Z, Tian X, et al. (2018). A recombinant trivalent vaccine candidate against human adenovirus types 3, 7, and 55. Vaccine, 36: 2199–2206.
Nielsen PV (2015). Fifty years of CFD for room air distribution. Building and Environment, 91: 78–90.
Qian H, Zheng X (2018). Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings. Journal of Thoracic Disease, 10: S2295–S2304.
Richard M, Herfst S, van den Brand JMA, et al. (2017). Mutations driving airborne transmission of A/H5N1 virus in mammals cause substantial attenuation in chickens only when combined. Scientific Reports, 7: 7187.
Sørensen LS (2007). An Introduction to Computational Fluid Dynamics: The Finite Volume Method. Pearson Schweiz Ag.
Shiu EYC, Leung NHL, Cowling BJ (2019). Controversy around airborne versus droplet transmission of respiratory viruses. Current Opinion in Infectious Diseases, 32: 372–379.
Singhal T (2020). A review of coronavirus disease-2019 (COVID-19). The Indian Journal of Pediatrics, 87: 281–286.
Sivagnanasundaram P, Amarasekara RWK, Madegedara RMD, et al. (2019). Assessment of airborne bacterial and fungal communities in selected areas of teaching hospital, Kandy, Sri Lanka. BioMed Research International, 2019: 7393926.
Su H, Yang X, Wang S, et al. (2018). Effect of annexin II-mediated conversion of plasmin from plasminogen on airborne transmission of H9N2 avian influenza virus. Veterinary Microbiology, 223: 100–106.
Ong SWX, Tan YK, Chia P, et al. (2020). Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient. JAMA, 323: 1610.
Tang JW, Li Y, Eames I, et al. (2006). Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. Journal of Hospital Infection, 64: 100–114.
Tang JW, Li Y (2019). The airborne microbiome—Implications for aerosol transmission and infection control. BMC Infectious Diseases, 19(1): 755.
Tellier R, Li Y, Cowling BJ, et al. (2019). Recognition of aerosol transmission of infectious agents: A commentary. BMC Infectious Diseases, 19: 101.
Tong X, Xu H, Zou L, et al. (2017). High diversity of airborne fungi in the hospital environment as revealed by meta-sequencing-based microbiome analysis. Scientific Reports, 7: 39606.
Wang H, Qian H, Zhou R, et al. (2020). A novel circulated air curtain system to confine the transmission of exhaled contaminants: A numerical and experimental investigation. Building Simulation, 13: 1425–1437.
Xiao S, Tang JW, Li Y (2017). Airborne or fomite transmission for norovirus? A case study revisited. International Journal of Environmental Research and Public Health, 14(12): 1571.
Xu P, Fisher N, Miller SL (2013). Using computational fluid dynamics modeling to evaluate the design of hospital ultraviolet germicidal irradiation systems for inactivating airborne mycobacteria. Photochem Photobiol, 89: 792–798.
Yan Y, Li X, Tu J (2017). Numerical investigations of the effects of manikin simplifications on the thermal flow field in indoor spaces. Building Simulation, 10: 219–227.
Acknowledgements
This study was supported by grants from the National Key Research and Development Program of China (2018YFC1200100, 2018YFC1200103), Guangdong Medical Science and Technology Research Center Project (A2019460), Entrepreneurship Leadership Project in Guangzhou Development Zone of China (CY2018-003), Guangzhou Science and Technology Project (202008040002), Scientific Research Project of Guangdong Province Traditional Chinese Medicine Bureau (20201191), Innovative and Strong School Project of Guangdong Provincial Department of Education (2020KZDZX1122), Guangdong Science and Technology Project (2020B111106001) and Foshan Science and Technology Innovation Project (2020001000416). Thanks Professor Qian Hua (School of Energy and Environment Southeast University, Nanjing, China) for helping us to do the CFD models.
Author information
Authors and Affiliations
Contributions
Rong Zhou, Tiantian Liu, and Zhengshi Lin were involved in the conception and design of the study. Tiantian Liu, Yubing Guo, Xiaotang Hao, Mei Wang and Shicong He were involved in the acquisition of the data. Tiantian Liu and Zhengshi Lin analyzed the data. Tiantian Liu wrote the manuscript.
Corresponding authors
Rights and permissions
About this article
Cite this article
Liu, T., Guo, Y., Hao, X. et al. Evaluation of an innovative pediatric isolation (PI) bed using fluid dynamics simulation and aerosol isolation efficacy. Build. Simul. 14, 1543–1552 (2021). https://doi.org/10.1007/s12273-021-0761-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12273-021-0761-3