Building Simulation

, Volume 11, Issue 4, pp 787–801 | Cite as

Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate

Research Article Indoor/Outdoor Airflow and Air Quality
  • 31 Downloads

Abstract

A novel integrated personalized ventilation and local fan-induced active chilled beam (PV-ACB) air conditioning system is proposed and analyzed through energy and Computational Fluid Dynamics (CFD) simulation methods. Energy performance and indoor environmental conditions of this system are investigated via Integrated Environmental Solutions (IES) and ANSYS Fluent respectively. Energy simulation results illustrate that PV-ACB system, compared with the conventional variable air volume (VAV) system, could achieve 16% energy savings at 100% peak cooling load. A maximum 42% energy savings is obtained at 25% part cooling load, indicating the superior energy saving potential under part load conditions. Vertical thermal stratification is observed in CFD simulation results, 23–24 °C at the occupant level (0–2 m) and 26–27 °C in the upper zone (2–4 m). Horizontally, temperature around occupants is 22–23 °C, lower than the temperature of 26–27 °C in other areas, demonstrating the horizontal temperature difference caused by the conditioned outdoor air from personalized ventilation. Both energy and CFD simulation results illustrate that this novel PV-ACB air conditioning system is able to achieve considerable energy savings, superior occupant thermal comfort and enhanced indoor air quality (IAQ).

Keywords

personalized ventilation fan-induced active chilled beam hot and humid climate computational fluid dynamics (CFD) energy simulation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Ahmed K, Kurnitski J, Sormunen P (2015). Demand controlled ventilation indoor climate and energy performance in a high performance building with air flow rate controlled chilled beams. Energy and Buildings, 109: 115–126.CrossRefGoogle Scholar
  2. ASHRAE (2016a). ASHRAE Handbook 2016—HVAC System and Equipment. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.Google Scholar
  3. ASHRAE (2016b). ASHRAE Standard 62.1-2016—Ventilation for Acceptable Indoor Air Quality. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.Google Scholar
  4. ASHRAE (2017). ASHRAE Handbook 2017—Fundamentals. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.Google Scholar
  5. BCA (2015). BCA Green Mark for Non-Residential Buildings. Singapore: Building and Construction Authority.Google Scholar
  6. Bastide A, Lauret P, Garde F, Boyer H (2006). Building energy efficiency and thermal comfort in tropical climates: Presentation of a numerical approach for predicting the percentage of well-ventilated living spaces in buildings using natural ventilation. Energy and Buildings, 38: 1093–1103.CrossRefGoogle Scholar
  7. Center for Climate Research Singapore (2016). Annual Climate Assessment 2015. Singapore.Google Scholar
  8. Cermak R, Melikov AK, Forejt L, Kovar O (2006). Performance of personalized ventilation in conjunction with mixing and displacement ventilation. HVAC&R Research, 12: 295–311.CrossRefGoogle Scholar
  9. Chen Q (1995). Comparison of different k-ε models for indoor air flow computations. Numerical Heat Transfer, Part B: Fundamentals, 28: 353–369.CrossRefGoogle Scholar
  10. Energy Market Authority (2015). Singapore Energy Statistics 2015. Singapore.Google Scholar
  11. Fabrizio E, Corgnati SP, Causone F, Filippi M (2012). Numerical comparison between energy and comfort performances of radiant heating and cooling systems versus air systems. HVAC&R Research, 18: 692–708.Google Scholar
  12. Gangisetti K, Claridge DE, Srebric J, Paulus MT (2016). Influence of reduced VAV flow settings on indoor thermal comfort in an office space. Building Simulation, 9:101–111.CrossRefGoogle Scholar
  13. Guan Z, Wen C (2016). Geometric optimization on active chilled beam terminal unit to achieve high entrainment efficiency. Applied Thermal Engineering, 98: 816–826.CrossRefGoogle Scholar
  14. Halvoňová B, Melikov AK (2010a). Performance of ductless personalized ventilation in conjunction with displacement ventilation: impact of workstations layout and partitions. HVAC&R Research, 16: 75–94.CrossRefGoogle Scholar
  15. Halvoňová B, Melikov AK (2010b). Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of disturbances due to walking person(s). Building and Environment, 45: 427–436.CrossRefGoogle Scholar
  16. Halvoňová B, Melikov AK (2010c). Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of intake height. Building and Environment, 45: 996–1005.CrossRefGoogle Scholar
  17. ISO (2005). BS EN ISO 7730: Ergonomics of the thermal environment—Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. Geneva: International Standardisation Organisation.Google Scholar
  18. Kong M, Zhang J, Wang J (2015). Air and air contaminant flows in office cubicles with and without personal ventilation: A CFD modeling and simulation study. Building Simulation, 8: 381–392.CrossRefGoogle Scholar
  19. Koskela H, Häggblom H, Kosonen R, Ruponen M (2010). Air distribution in office environment with asymmetric workstation layout using chilled beams. Building and Environment, 45: 1923–1931.CrossRefGoogle Scholar
  20. Koskela H, Häggblom H, Kosonen R, Ruponen M (2012). Flow pattern and thermal comfort in office environment with active chilled beams. HVAC&R Research, 18: 723–736.Google Scholar
  21. Kosonen R, Tan F (2005). A feasibility study of a ventilated beam system in the hot and humid climate: A case-study approach. Building and Environment, 40: 1164–1173.CrossRefGoogle Scholar
  22. Launder BE, Spalding DB (1974). The numerical computation of turbulent flows. Computer Methods on Applied Mechanics and Engineering, 3: 269–289.CrossRefMATHGoogle Scholar
  23. Li R, Sekhar SC, Melikov AK (2010). Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate. Building and Environment, 45: 1906–1913.CrossRefGoogle Scholar
  24. Lipczynska A, Kaczmarczyk J, Melikov AK (2014). Performance of radiant cooling ceiling combined with personalized ventilation in an office room: identification of thermal conditions. Paper presented at 13th International Conference on Indoor Air Quality and Climate, Hong Kong, China.Google Scholar
  25. Lyubenova VS, Holsøe JW, Melikov AK (2011). Potential energy savings with personalized ventilation coupled with passive chilled beams. In: Proceedings of 12th International Conference on Air Distribution in Rooms (RoomVent 2011), Trondheim, Norway.Google Scholar
  26. Maccarini A, Hultmark G, Vorre A, Afshari A, Bergsøe NC (2015). Modeling of active beam units with Modelica. Building Simulation, 8: 543–550.CrossRefGoogle Scholar
  27. Makhoul A, Ghali K, Ghaddar N (2013). Thermal comfort and energy performance of a low-mixing ceiling-mounted personalized ventilator system. Building and Environment, 60: 126–136.CrossRefGoogle Scholar
  28. McIntyre DA (1980). Indoor Climate. London: Elsevier.Google Scholar
  29. Meggers F, Pantelic J, Baldini L, Saber EM, Kim MK (2013). Evaluating and adapting low exergy systems with decentralized ventilation for tropical climates Energy and Buildings, 67: 559–567.CrossRefGoogle Scholar
  30. Melikov A, Ivanova T, Stefanova G (2012). Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality. Building and Environment, 47: 100–108.CrossRefGoogle Scholar
  31. Mirrahimi S, Mohamed MF, Haw LC, Ibrahim NLN, Yusoff WFM, Aflaki A (2016). The effect of building envelope on the thermal comfort and energy saving for high-rise buildings in hot–humid climate. Renewable and Sustainable Energy Reviews, 53: 1508–1519.CrossRefGoogle Scholar
  32. Mumma SA (2002). Chilled ceilings in parallel with dedicated outdoor air systems: Addressing the concerns of condensation, capacity, and cost. ASHRAE Transactions, 108(2): 220–231.Google Scholar
  33. Mumma SA (2010). Dedicated Outdoor Air Systems and Building Pressurization. ASHRAE Transactions, 116(2): 143–153.MathSciNetGoogle Scholar
  34. Murphy J (2009). Role of safety factors in the design of dedicated outdoor-air systems. ASHRAE Transactions, 115(2): 358–368.Google Scholar
  35. Nielsen PV (1998). The selection of turbulence models for prediction of room airflow. ASHRAE Transactions, 104(1): 1119–1127.Google Scholar
  36. Nielsen PV, Bartholomaeussen NM, Jakubowska E, Jiang H, Jonsson OT, Krawiecka K, Mierzejewski A, Jessica S, Trampczynska K, Polak M (2007). Chair with integrated personalized ventilation for minimizing cross infection. In: Proceedings of 10th International Conference on Air Distribution in Rooms (RoomVent 2007), Helsinki, Finland.Google Scholar
  37. Novoselac A, Srebric J (2002). A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems. Energy and Buildings, 34: 497–509.CrossRefGoogle Scholar
  38. Rhee K-N, Shin M-S, Choi S-H (2015). Thermal uniformity in an open plan room with an active chilled beam system and conventional air distribution systems. Energy and Buildings, 93: 236–248.CrossRefGoogle Scholar
  39. Schiavon S, Melikov AK (2009). Energy-saving strategies with personalized ventilation in cold climates. Energy and Buildings, 41: 543–550.CrossRefGoogle Scholar
  40. Schiavon S, Melikov AK, Sekhar C (2010). Energy analysis of the personalized ventilation system in hot and humid climates. Energy and Buildings, 42: 699–707.CrossRefGoogle Scholar
  41. Seo J-M, Song D, Lee KH (2014). Possibility of coupling outdoor air cooling and radiant floor cooling under hot and humid climate conditions. Energy and Buildings, 81: 219–226.CrossRefGoogle Scholar
  42. Shen C, Gao N, Wang T (2013). CFD study on the transmission of indoor pollutants under personalized ventilation. Building and Environment, 63: 69–78.CrossRefGoogle Scholar
  43. SPRING Singapore. (2016). SS 553: 2009—Code of Practice for Airconditioning and Mechanical Ventilation in Buildings. Singapore.Google Scholar
  44. Sørensen DN, Nielsen PV (2003). Quality control of computational fluid dynamics in indoor environments. Indoor Air, 13: 2–17.CrossRefGoogle Scholar
  45. Versteeg HK, Malalasekera W (2007). An Introduction to Computational Fluid Dynamics: The Finite Volume Method, 2nd edn. Harlow, UK: Pearson Education.Google Scholar
  46. Woollett J, Rimmer J (2014). Active and Passive Beam Application Design Guide. Brussels: REHVA—Federation of European Heating, Vent ilation and Air Conditioning Associations.Google Scholar
  47. Yang B, Sekhar C, Melikov AK (2010). Ceiling mounted personalized ventilation system in hot and humid climate—An energy analysis. Energy and Buildings, 42: 2304–2308.CrossRefGoogle Scholar
  48. Yang B, Sekhar C (2013). Interaction of dynamic indoor environment with moving person and performance of ceiling mounted personalized ventilation system. Indoor and Built Environment, 23: 920–932.CrossRefGoogle Scholar
  49. Yang C, Yang X, Zhao B (2015). The ventilation needed to control thermal plume and particle dispersion from manikins in a unidirectional ventilated protective isolation room. Building Simulation, 8: 551–565.CrossRefGoogle Scholar

Copyright information

© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of Building, School of Design and EnvironmentNational University of SingaporeSingaporeSingapore

Personalised recommendations