Daylighting and visual comfort of oriental sun responsive skins: A parametric analysis

  • Amir Tabadkani
  • Saeed Banihashemi
  • M. Reza Hosseini
Research Article Building Thermal, Lighting, and Acoustics Modeling

Abstract

This study reports on developing an innovative approach for the parametric analysis of daylighting and visual comfort, through a sun responsive shading system. The objective is estimating the annual daylight metrics and indoor glare discomfort. To this end, a review of the literature was carried out on three key concepts: smart facades, visual comfort, and parametric design, in order to develop a dynamic pattern of an oriental system for enhancing the daylight and visual performance. Afterwards, two geometrical components (Rosette modules and louvers) were applied, using Grasshopper plug-in for Rhino and daylighting plug-in DIVA, to investigate the indoor daylight quality through different geometrical and physical properties. This resulted in generating 6480 design variants, when several variables (rotation, distance to facade, time hours, transmittance properties and colors) that affect incoming daylight as well as visual comfort performance in a single office space in the hot-arid climate of Tehran were taken into account. Interactive correlations between the overall performance of kinetic patterns and visual performance were investigated through an optimization process. Analyses showed that the proposed approach is capable of significantly improving the shading flexibility to control daylight metrics and glare, via a full potential adaptive pattern to achieve the maximum visual comfort level based on LEEDv4 certificate.

Keywords

oriental skin daylight performance visual comfort algorithmic simulation parametric study optimization 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Supplementary material

12273_2018_433_MOESM1_ESM.pdf (445 kb)
Daylighting and visual comfort of oriental sun responsive skins: A parametric analysis

References

  1. Abdullahi Y, Embi MRB (2013). Evolution of Islamic geometric patterns. Frontiers of Architectural Research, 2: 243–251.CrossRefGoogle Scholar
  2. Banihashemi S, Hassanabadi MS, Sadeghifam AN (2012). Analysis of behavior of windows in terms of saving energy in extreme cold weather climes of Iran. International Journal of Engineering and Technology, 4: 676–679.CrossRefGoogle Scholar
  3. Banihashemi S, Golizadeh H, Hosseini MR, Shakouri M (2015). Climatic, parametric and non-parametric analysis of energy performance of double-glazed windows in different climates. International Journal of Sustainable Built Environment, 4: 307–322.CrossRefGoogle Scholar
  4. Banihashemi S, Tabadkani A, Hosseini MR (2017). Modular coordination-based generative algorithm to optimize construction waste. Procedia Engineering, 180: 631–639.CrossRefGoogle Scholar
  5. World Bank (2014). World Development Indicators 1960–2013. Washington DC: World Bank.Google Scholar
  6. Bellia L, Fragliasso F, Stefanizzi E (2017). Daylit offices: A comparison between measured parameters assessing light quality and users’ opinions. Building and Environment, 113: 92–106.CrossRefGoogle Scholar
  7. Bodart M, Cauwerts C (2017). Assessing daylight luminance values and daylight glare probability in scale models. Building and Environment, 113: 210–219.CrossRefGoogle Scholar
  8. Boyce P, Hunter C, Howlett O (2003). The benefits of daylight through windows. Rensselaer Polytechnic Institute.Google Scholar
  9. Carlucci S, Causone F, De Rosa F, Pagliano L (2015). A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design. Renewable and Sustainable Energy Reviews, 47: 1016–1033.CrossRefGoogle Scholar
  10. Costa A, Keane MM, Torrens JI, Corry E (2013). Building operation and energy performance: Monitoring, analysis and optimisation toolkit. Applied Energy, 101: 310–316.CrossRefGoogle Scholar
  11. USGBC (2015). Leadership in Energy and Environmental Design (LEED). U.S. Green Building Council.Google Scholar
  12. Duffy JF, Czeisler CA (2009). Effect of light on human circadian physiology. Sleep Medicine Clinics, 4: 165–177.CrossRefGoogle Scholar
  13. ECS (2011a.) EN 12464-1. Light and lighting—Lighting of work places—Indoor work places. Brussels: European Committee for Standardization.Google Scholar
  14. ECS (2011b). EN 12665. Light and lighting—Basic terms and criteria for specifying lighting requirements. Brussels: European Committee for Standardization.Google Scholar
  15. El ouaazizi A, Nasri A, Benslimane R (2015). A rotation symmetry group detection technique for the characterization of Islamic Rosette Patterns. Pattern Recognition Letters, 68: 111–117.CrossRefGoogle Scholar
  16. Favoino F, Fioritio F, Cannavale A, Ranzi G, Overend M (2016). Optimal control and performance of photovoltachromic switchable glazing for building integration in temperate climates. Applied Energy, 178: 943–961.CrossRefGoogle Scholar
  17. Greenberg D, Pratt K, Hencey B, Jones N, Schumann L, Dobbs J, Dong Z, Bosworth D, Walter B (2013). Sustain: An experimental test bed for building energy simulation. Energy and Buildings, 58: 44–57.CrossRefGoogle Scholar
  18. Gunay HB, O’Brien W, Beausoleil-Morrison I, Gilani S (2017). Development and implementation of an adaptive lighting and blinds control algorithm. Building and Environment, 113: 185–199.CrossRefGoogle Scholar
  19. Gürsel Dino | (2012). Creative design exploration by parametric generative systems in architecture. METU Journal of Faculty of the Architecture, 29(1): 207–224.Google Scholar
  20. Hassanabadi MS, Banihashemi S (2012). Developing an empirical predictive energy-rating model for windows by using Artificial Neural Network. International Journal of Green Energy, https://doi.org/10.1080/15435075.2012.738451.Google Scholar
  21. Hassanabadi MS, Banihashemi S, Javaheri AR (2012). Analysis and comparison of impacts of design optimization approaches with occupant behavior on energy consumption reduction in residential buildings. International Journal of Engineering and Technology, 4: 680–683.CrossRefGoogle Scholar
  22. IESNA (2012). LM-83-12 IES. Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). New York, NY: IESNA Lighting Measurement.Google Scholar
  23. Jacobs A (2012). Radiance Cookbook. Available at http://www.radianceonline. org.Google Scholar
  24. Jakubiec JA, Reinhart CF (2011). DIVA 2.0: Integrating daylight and thermal simulations using Rhinoceros 3D, Daysim and EnergyPlus. In: Proceedings of the 12th International IBPSA Building Simulation Conference, Sydney, Australia, pp. 2202–2209.Google Scholar
  25. Karanouh A, Kerber E (2015). Innovations in dynamic architecture. Journal of Facade Design and Engineering, 3: 185–221.CrossRefGoogle Scholar
  26. Klepeis NE, Nelson WC, Ott WR, Robinson JP, Tsang AM, Switzer P, Behar JV, Hern SC, Engelmann WH (2001). The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants. Journal of Exposure Science and Environmental Epidemiology, 11: 231–252.CrossRefGoogle Scholar
  27. Konis K (2017). A novel circadian daylight metric for building design and evaluation. Building and Environment, 113: 22–38.CrossRefGoogle Scholar
  28. Konstantzos I, Tzempelikos A (2017). Daylight glare evaluation with the sun in the field of view through window shades. Building and Environment, 113: 65–77.CrossRefGoogle Scholar
  29. Lavin C, Fiorito F (2017). Optimization of an external perforated screen for improved daylighting and thermal performance of an office space. Procedia Engineering, 180: 571–581.CrossRefGoogle Scholar
  30. Leach N (2009). Digital morphogenesis. Architectural Design, 79: 32–37.CrossRefGoogle Scholar
  31. Loonen RCGM, Trčka M, Cóstola D, Hensen JLM (2013). Climate adaptive building shells: State-of-the-art and future challenges. Renewable and Sustainable Energy Reviews, 25: 483–493.CrossRefGoogle Scholar
  32. López M, Rubio R, Martín S, Croxford B, Jackson R (2015). Active materials for adaptive architectural envelopes based on plant adaptation principles. Journal of Facade Design and Engineering, 3: 27–38.CrossRefGoogle Scholar
  33. Mahmoud AHA, Elghazi Y (2016). Parametric-based designs for kinetic facades to optimize daylight performance: Comparing rotation and translation kinetic motion for hexagonal facade patterns. Solar Energy, 126: 111–127.CrossRefGoogle Scholar
  34. Narangerel A, Lee J-H, Stouffs R (2016). Daylighting Based Parametric Design Exploration of 3D Facade Patterns. In: Proceedings of the 34th eCAADe Conference, At Oulu, Finland, PauleyGoogle Scholar
  35. SM (2004). Lighting for the human circadian clock: Recent research indicates that lighting has become a public health issue. Medical Hypotheses, 63: 588–596.CrossRefGoogle Scholar
  36. Pellegrino A, Cammarano S, Lo Verso VRM, Corrado V (2017). Impact of daylighting on total energy use in offices of varying architectural features in Italy: Results from a parametric study. Building and Environment, 113: 151–162.CrossRefGoogle Scholar
  37. Pesenti M, Masera G, Fiorito F (2015). Shaping an Origami shading device through visual and thermal simulations. Energy Procedia, 78: 346–351.CrossRefGoogle Scholar
  38. Reinhart CF (2004). Lightswitch-2002: A model for manual and automated control of electric lighting and blinds. Solar Energy, 77: 15–28.CrossRefGoogle Scholar
  39. Reinhart CF, Mardaljevic J, Rogers Z (2006). Dynamic daylight performance metrics for sustainable building design. Leukos, 3: 7–31.Google Scholar
  40. Reinhart CF, Wienold J (2011). The daylighting dashboard—A simulation-based design analysis for daylit spaces. Building and Environment, 46: 386–396.CrossRefGoogle Scholar
  41. Reinhart CF (2014). Daylighting Handbook I: Fundamentals; Designing with the Sun.Google Scholar
  42. Rogers Z (2006). Daylighting metric development using daylight autonomy calculations in the sensor placement optimization tool. Available at http://www. archenergy. com/SPOT/SPOT_Daylight% 20Autonomy% 20Report. pdf.Google Scholar
  43. Rubiño M, Cruz A, Garcia JA, Hita E (1994). Discomfort glare indices: a comparative study. Applied Optics, 33: 8001–8008.CrossRefGoogle Scholar
  44. Rutten D (2013). Galapagos: On the logic and limitations of generic solvers. Architectural Design, 83: 132–135.CrossRefGoogle Scholar
  45. Thornton Tomasetti (2017). Design Explorer. Github. Available at http://tt-acm.github.io/DesignExplorer.Google Scholar
  46. Tzempelikos A, Athienitis AK (2007). The impact of shading design and control on building cooling and lighting demand. Solar Energy, 81: 369–382.CrossRefGoogle Scholar
  47. Ward GJ (1994). The RADIANCE lighting simulation and rendering system. In: Proceedings of the 21st International ACM Conference on Computer Graphics and Interactive Techniques, Orlando, FL, USA, pp. 459–472.Google Scholar
  48. Wienold J, Christoffersen J (2006). Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras. Energy and Buildings, 38: 743–757.CrossRefGoogle Scholar
  49. Yun G, Park DY, Kim KS (2017). Appropriate activation threshold of the external blind for visual comfort and lighting energy saving in different climate conditions. Building and Environment, 113: 247–266.CrossRefGoogle Scholar

Copyright information

© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Amir Tabadkani
    • 1
  • Saeed Banihashemi
    • 2
  • M. Reza Hosseini
    • 3
  1. 1.Department of Building and Architectural EngineeringPolitecnico di MilanoMilanoItaly
  2. 2.School of Built Environment and DesignUniversity of CanberraCanberraAustralia
  3. 3.School of Architecture and Built EnvironmentDeakin UniversityGeelongAustralia

Personalised recommendations