Building Simulation

, Volume 11, Issue 3, pp 549–560 | Cite as

Analysis on the optimum matching of collector and storage size of solar water heating systems in building space heating applications

Research Article Building Systems and Components
  • 30 Downloads

Abstract

The overall thermal performance of a solar water heating (SWH) system is significantly affected by the mismatch between the temporal distribution of solar radiation and the heating load. Therefore, a favorable correlation between the collector and storage size should be generated based on the dynamic characteristics of the system. This study focuses on the optimal matching of solar collector area with storage volume for an SWH system (with short-term heat storage capability) for a space heating application. A simplified model of an SWH system based on hourly energy flow is established. System control strategy is integrated into the model in a simple manner without sacrificing computing speed. Based on this model, the combined effect of collector area and storage volume on system thermal performance and economy is analyzed, and a simple procedure for determining the optimal system size is illustrated. A case study showed that for an SWH system utilized for space heating application, the optimized ratio between storage volume and collector area is dependent on the total collector area of the system, and is dominated by the requirement of overheating prevention. The minimum storage volume for a specific collector area that can prevent the storage tank from being overheated can be adopted as the optimum storage volume for that collector area. The optimum ratio between storage volume and collector area increases as the collector area increases. Therefore, a trade-off between heat collection and heat loss has to be made while attempting to increase solar fraction by improving collector area.

Keywords

solar water heating renewable energy optimization space heating thermal storage 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgements

The study is supported by the International S&T Cooperation Program of China (ISTCP) (No. 2015DFG62410) and the National Key Technology Research and Development Program of the Ministry of Science and Technology of China (No. 2014BAA01B03).

References

  1. Abou-Zeid MR, Hawas MM (1983). Economic evaluation and optimization of solar systems for space and domestic water heating. Energy Conversion and Management, 23: 251–256.CrossRefGoogle Scholar
  2. ASHRAE (1988). Active Solar Heating Systems Design Manual. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.Google Scholar
  3. Ardente F, Beccali G, Cellura M, Lo Brano V (2005). Life cycle assessment of a solar thermal collector. Renewable Energy, 30: 1031–1054.CrossRefGoogle Scholar
  4. Atia DM, Fahmy FH, Ahmed NM, Dorrah HT (2012). Optimal sizing of a solar water heating system based on a genetic algorithm for an aquaculture system. Mathematical and Computer Modelling, 55: 1436–1449.CrossRefGoogle Scholar
  5. Buckles WE, Klein SA (1980). Analysis of solar domestic hot water heaters. Solar Energy, 25: 417–424.CrossRefGoogle Scholar
  6. Çomakli K, Çakir U, Kaya M, Bakirci K (2012). The relation of collector and storage tank size in solar heating systems. Energy Conversion and Management, 63: 112–117.CrossRefGoogle Scholar
  7. Courtney RG (1977). A computer study of solar water heating. Building and Environment, 12: 73–80.CrossRefGoogle Scholar
  8. Cruickshank CA, Harrison SJ (2010). Heat loss characteristics for a typical solar domestic hot water storage. Energy and Buildings, 42: 1703–1710.CrossRefGoogle Scholar
  9. Deng J, Yang X, Ma R, Xu Y (2016). Study on the thermodynamic characteristic matching property and limit design principle of general flat plate solar air collectors (FPSACs). Building Simulation, 9: 529–540.CrossRefGoogle Scholar
  10. Deng J, Yang X, Xu Y, Yang M (2017). Entransy analysis on the thermal performance of flat plate solar air collectors. Building Simulation, 10: 193–202.CrossRefGoogle Scholar
  11. Barley CD, Winn CB (1978). Optimal sizing of solar collectors by the method of relative areas. Solar Energy, 21: 279–289.CrossRefGoogle Scholar
  12. Duffie JA, Beckman WA (2013). Solar Engineering of Thermal Processes, 4th edn. Hoboken, NJ, USA: John Wiley & Sons.CrossRefGoogle Scholar
  13. Hang Y, Du L, Qu M, Peeta S (2013). Multi-objective optimization of integrated solar absorption cooling and heating systems for medium-sized office buildings. Renewable Energy, 52: 67–78.CrossRefGoogle Scholar
  14. Hassan MM, Beliveau Y (2008). Modeling of an integrated solar system. Building and Environment, 43: 804–810.CrossRefGoogle Scholar
  15. Hobbi A, Siddiqui K (2009). Optimal design of a forced circulation solar water heating system for a residential unit in cold climate using TRNSYS. Solar Energy, 83: 700–714.CrossRefGoogle Scholar
  16. Kalogirou S (2009). Thermal performance, economic and environmental life cycle analysis of thermosiphon solar water heaters. Solar Energy, 83: 39–48.CrossRefGoogle Scholar
  17. Klein SA, Beckman WA (1979). A general design method for closedloop solar energy systems. Solar Energy, 22: 269–282.CrossRefGoogle Scholar
  18. Klein S, Beckman W, Duffie J (1976). A design procedure for solar heating systems. Solar Energy, 18: 113–127.CrossRefGoogle Scholar
  19. Kulkarni GN, Kedare SB, Bandyopadhyay S (2006). The concept of design space for sizing solar hot water systems. In: Proceedings of International Congress on Renewable Energy, Hyderabad, India, pp. 302–305.Google Scholar
  20. Kulkarni GN, Kedare SB, Bandyopadhyay S (2007). Determination of design space and optimization of solar water heating systems. Solar Energy, 81: 958–968.CrossRefGoogle Scholar
  21. Mezni T, Zainine MA, Dakhlaoui MA, Zghal A (2017). Presentation and experimental validation of a solar DHW installation sizing control tool. International Journal of Hydrogen Energy, 42: 28958–28972.CrossRefGoogle Scholar
  22. Ozgener O, Hepbasli A (2007). A parametrical study on the energetic and exergetic assessment of a solar-assisted vertical ground-source heat pump system used for heating a greenhouse. Building and Environment, 42: 11–24.CrossRefGoogle Scholar
  23. Pei G, Li G, Zhou X, Ji J, Su Y (2012). Experimental study and exergetic analysis of a CPC-type solar water heater system using higher-temperature circulation in winter. Solar Energy, 86: 1280–1286.CrossRefGoogle Scholar
  24. Real Decreto (2009). Código técnico de la edificación. Madrid, Spain: Boletín Oficial del Estado.Google Scholar
  25. Rodriguez-Hidalgo MC, Rodriguez-Aumente PA, Lecuona A, Legrand M, Ventas R (2012). Domestic hot water consumption vs. solar thermal energy storage: The optimum size of the storage tank. Applied Energy, 97: 897–906.Google Scholar
  26. Sillman S (1981). The Trade-Off Between Collector Area, Storage Volume, and Building Conservation in Annual Storage Solar Heating Systems. Golden, CO, USA: Solar Energy Research Institute.Google Scholar
  27. Wang D, Liu Y (2010). Study on heat storage tank of solar heating system. In: Proceedings of International Conference on Digital Manufacturing and Automation (ICDMA), Changsha, China, pp. 493–497.Google Scholar
  28. Xia J, Zhu K, Jiang Y (2016). Method for integrating low-grade industrial waste heat into district heating network. Building Simulation, 9: 153–163.CrossRefGoogle Scholar
  29. Yan C, Wang S, Ma Z, Shi W (2015). A simplified method for optimal design of solar water heating systems based on life-cycle energy analysis. Renewable Energy, 74: 271–278.CrossRefGoogle Scholar
  30. Yan C, Shi W, Li X, Zhao Y (2016). Optimal design and application of a compound cold storage system combining seasonal ice storage and chilled water storage. Applied Energy, 171: 1–11.CrossRefGoogle Scholar
  31. Yan D, Xia J, Tang W, Song F, Zhang X, Jiang Y (2008). DeST—An integrated building simulation toolkit Part I: Fundamentals. Building Simulation, 1: 95–110.CrossRefGoogle Scholar
  32. Zainine MA, Dakhlaoui MA, Mezni T, Guizani A (2016). Energetic and economic impact of using bioclimatic design technics and of solar water preheating system integration on tertiary building. International Journal of Renewable Energy Research, 6: 787–794.Google Scholar
  33. Zainine MA, Mezni T, Dakhlaoui MA, Guizani A (2017). Energetic performance and economic analysis of a solar water heating system for different flow rates values: A case study. Solar Energy, 147: 164–180.CrossRefGoogle Scholar
  34. Zhao DL, Li Y, Dai YJ, Wang RZ (2011). Optimal study of a solar air heating system with pebble bed energy storage. Energy Conversion and Management, 52: 2392–2400.CrossRefGoogle Scholar

Copyright information

© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Fang Guo
    • 1
  • Junyue Zhang
    • 2
  • Ming Shan
    • 1
  • Xudong Yang
    • 1
  1. 1.Department of Building Science, School of ArchitectureTsinghua UniversityBeijingChina
  2. 2.Chifeng Heran Energy-Saving Science and Technology Co., LTDInner MongoliaChina

Personalised recommendations