Skip to main content
Log in

Assessment of pre-heating air through a double window system on different building location and weather condition

  • Research Article
  • Building Systems and Components
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Double windows are a currently adopted construction system in Portuguese dwellings. Simple changes enable this construction system to pre-heat the ventilation air. The air coming from the outside circulates goes upward through the channel between windows where it is pre-heated before entering the building. Heat that escapes from inside through the inner window and solar radiation, heats up the air between the two windows. This paper presents the performance of such passive system and focuses on the design aspects of this system and its building integration in function of weather conditions. One type of building is used where the window is located on different facades, thus, different orientations. Four different weather conditions are chosen, from mild to cold winters. The methodology used is based on previous validated parametric studies. Results indicate that the ventilated double window system offers an alternative to cold natural ventilation in any cold region and any facade orientation. The colder the location, the higher the pre-heating of the incoming air. This study expects to help designers to conceive ventilated double windows duly adapted to local climate where natural ventilation is an important design consideration and where energy consumption must be reduced.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Appelfeld D, Svendsen S (2011). Experimental analysis of energy performance of a ventilated window for heat recovery under controlled conditions. Energy and Buildings, 43: 3200–3207.

    Google Scholar 

  • Baker PH, McEvoy M (2000). Test cell analysis of the use of a supply air window as a passive solar component. Solar Energy, 69: 113–130.

    Google Scholar 

  • Carlos JS, Corvacho H, Silva PD, Castro-Gomes JP (2010). Real climate experimental study of two double window systems with preheating of ventilated air. Energy and Buildings, 42: 928–934.

    Google Scholar 

  • Carlos JS, Corvacho H, Silva PD, Castro-Gomes JP (2011). Modelling and simulation of a ventilated double window. Applied Thermal Engineering, 31: 93–102.

    Google Scholar 

  • Carlos JS, Corvacho H (2010). Retrofit measures in old elementary school buildings towards energy efficiency. Journal of Civil Engineering and Management, 16: 567–576.

    Google Scholar 

  • CEC (Commission of the European Communities) (1993). Energy in Architecture—The European Passive Solar Handbook. London: B. T. Batsford Limited.

    Google Scholar 

  • Chvatal KMS, Corvacho H (2009). The impact of increasing the building envelope insulation upon the risk of overheating in summer and an increased energy consumption. Journal of Building Performance Simulation, 2: 267–282.

    Google Scholar 

  • Crawley DB, Hand JW, Kummert M, Griffith BT (2008). Contrasting the capabilities of building energy performance simulation programs. Building and Environment, 43: 661–673.

    Google Scholar 

  • Crawley DB, Lawrie LK, Pedersen CO, Winkelmann FC (2000). EnergyPlus: Energy simulation program. ASHRAE Journal, 42(4): 49–56.

    Google Scholar 

  • DOE-2 (1982). Engineering Manual, Version 2.1C. Berkeley: Lawrence Berkeley Laboratory.

    Google Scholar 

  • EN 832 (1998). Thermal Performance of Buildings—Calculation of Energy Use for Heating—Residential Buildings. European Committee for Standardization.

    Google Scholar 

  • Faggembauu D, Costa M, Soria M, Oliva A (2003). Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II: Applications and analysis of results. Solar Energy, 75: 229–239.

    Google Scholar 

  • Flamant G, Heijmans N, Guiot E (2004). Determination of the Energy Performances of Ventilated Double Facades by the Use of Simulation Integrating the Control Aspects—Modelling Aspects and Assessment of the Applicability of Several Simulation Software. Belgian Building Research Institute.

    Google Scholar 

  • Fleck BA, Meier RM, Matovic MD (2002). A field study of the wind effects on the performance of an unglazed transpired solar collector. Solar Energy, 73: 209–216.

    Google Scholar 

  • Gosselin JR, Chen QY (2008). A computational method for calculating heat transfer and airflow through a dual-airflow window. Energy and Buildings, 40: 452–458.

    Google Scholar 

  • Hastings SR, Mørck O (2000). Solar Air Systems—A Design Handbook. London: International Energy Agency.

    Google Scholar 

  • Infield D, Mei L, Eicker U (2004). Thermal performance estimation for ventilated PV facades. Solar Energy, 76: 93–98.

    Google Scholar 

  • ISO 15099 (2003). Thermal Performance of Windows, Doors and Shading Devices e Detailed Calculations. International Organization for Standardization.

    Google Scholar 

  • ISO 7730 (1994). Moderate Thermal Environments—Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort. International Organization for Standardization.

    Google Scholar 

  • Jurelioni A, Isevičius E (2008). CFD predictions of indoor air movement induced by cold window surfaces. Journal of Civil Engineering and Management, 14: 29–38.

    Google Scholar 

  • LBNL (Lawrence Berkeley National Laboratory) (2003). COMIS Multizone Air Flow Model, International Energy Agency (IEA). Available: http://epb.lbl.gov/comis. Accessed Nov. 2007.

    Google Scholar 

  • Lechner N (2009). Heating, Cooling, Lighting—Sustainable Design Methods for Architects, 3nd edn. Hoboken, NJ, USA: John Wiley & Sons.

    Google Scholar 

  • Linden PF (1999). The fluid mechanics of natural ventilation. Annual Review Fluid Mechanics, 31: 210–238.

    Google Scholar 

  • McEvoy M, Southall R (2010). A programme of testing to evaluate a passive approach to whole-house ventilation. Construction Innovation: Information, Process, Management, 10: 395–407.

    Google Scholar 

  • McEvoy ME, Southall RG, Baker PH (2003). Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques. Energy and Buildings, 35: 1009–1020.

    Google Scholar 

  • Mendler S, Odell W, Lazarus MA (2006). The Guidebook to Sustainable Design, 2nd edn. Hoboken, NJ, USA: John Wiley & Sons.

    Google Scholar 

  • Metzger J, Matuska T, Schranzhofer H (2009). A comparative simulation study of solar flat-plate collectors directly and indirectly integrated into the building envelope. In: Proceedings of International Conference of Building Simulation, Glasgow, UK, pp. 805–810.

    Google Scholar 

  • Murray SN, Rocher B, O’Sullivan DTJ (2012). Static simulation: A sufficient modelling technique for retrofit analysis. Energy and Buildings, 47: 113–121.

    Google Scholar 

  • Negro SO, Alkemade F, Hekkert MP (2012). Why does renewable energy diffuse so slowly? A review of innovation system problems. Renewable and Sustainable Energy Reviews, 16: 3836–3846.

    Google Scholar 

  • Nielsen T R (2005). Simple tool to evaluate energy demand and indoor environment in the early stages of building design. Solar Energy, 78: 73–83.

    Google Scholar 

  • Ochoa CE, Capeluto IG (2009). Advice tool for early design stages of intelligent facades based on energy and visual comfort approach. Energy and Buildings, 41: 480–488.

    Google Scholar 

  • Ohba M, Irie K, Kurabuchi T (2001). Study on air flow characteristics inside and outside a cross-ventilation model, and ventilation flow rates using wind tunnel experiments. Journal of Wind Engineering and Industrial Aerodynamics, 89: 1513–1524.

    Google Scholar 

  • Orme M (2001). Estimates of the energy impact of ventilation and associated financial expenditures. Energy and Buildings, 33: 199–205.

    Google Scholar 

  • Park CS (2003). Occupant responsive optimal control of smart facade system. PhD Thesis, Georgia Institute of Technology.

    Google Scholar 

  • Petersen S, Svendsen S (2010). Method and simulation program informed decisions in the early stages of building design. Energy and Buildings, 42: 1113–1119.

    Google Scholar 

  • Pfafferott J (2003). Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency. Energy and Buildings, 35: 971–983.

    Google Scholar 

  • Pottler K, Sippel CM, Beck A, Fricke J (1999). Optimized finned absorber geometries for solar air heating collectors. Solar Energy, 67: 35–52.

    Google Scholar 

  • Prajongsan P, Sharples S (2012). Enhancing natural ventilation, thermal comfort and energy savings in high-rise residential buildings in Bangkok through the use of ventilation shafts. Building and Environment, 50: 104–113.

    Google Scholar 

  • Quesada G, Rousse D, Dutil Y, Badache M, Hallé S (2012). A comprehensive review of solar facades. Transparent and translucent solar facades. Renewable and Sustainable Energy Reviews, 16: 2643–2651.

    Google Scholar 

  • Retzlaff RC (2009). Green buildings and building assessment systems: A new area of interest for planners. Journal of Planning Literature, 24: 3–21.

    Google Scholar 

  • Safer N, Woloszyn M, Roux JJ (2005). Three-dimensional simulation with a CFD tool of the airflow phenomena in single floor double-skin facade equipped with a venetian blind. Solar Energy, 79: 193–203.

    Google Scholar 

  • Santamouris M, Dascalaki E (1998). Natural ventilation in buildings—A design handbook. London: James & James.

    Google Scholar 

  • Schmidt D (2006). “Exergy”—Conscious design in the built environment. In: Fazio G, Rao D (eds), Research in Building Physics and Building Engineering. London: Taylor & Francis, pp. 563–569.

    Google Scholar 

  • Short C, Alan C, Malcolm C, Paul C, Al-Maiyah S (2010). Low energy refurbishment strategies for health buildings. Journal of Building Performance Simulation, 3: 197–216.

    Google Scholar 

  • Suárez MJ, Gutiérrez AJ, Pistono J, Blanco E (2011). CFD analysis of heat collection in a glazed gallery. Energy and Buildings, 43: 108–116.

    Google Scholar 

  • Weia J, Zhaoa J, Chena Q (2010). Energy performance of a dual airflow window under different climates. Energy and Buildings, 42: 111–122.

    Google Scholar 

  • Yamaguchi Y, Shimoda Y (2010). District-scale simulation for multi-purpose evaluation of urban energy systems. Journal of Building Performance Simulation, 3: 289–305.

    Google Scholar 

  • Yannas S (1994). Solar energy and housing design—Vol. 2: Examples. London: Architectural Association Publications.

    Google Scholar 

  • Zaretsky M (2010). Precedents in Zero-Energy Design: Architecture and Passive Design in the 2007 Solar Decathlon. New York: Routledge.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jorge S. Carlos.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Carlos, J.S. Assessment of pre-heating air through a double window system on different building location and weather condition. Build. Simul. 7, 247–261 (2014). https://doi.org/10.1007/s12273-013-0148-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-013-0148-1

Keywords

Navigation