Abstract
For local radiotherapy, a three-dimensional (3D) conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single source is obtained using the Monte Carlo method, and the spatial dose maps are combined linearly to acquire the dose distribution. The dose distribution is visualized through the real-time display of the isodose line and isodose surface combined with the reconstructed 3D organ groups. By observing 3D dose coverage to the target volume and surrounding tissues, dose planning could be initiated with greater accuracy and precision to avoid dose dead zones and excessively high-dose levels, thus achieving the 3D conformal dose planning objective. Further research into the impact that blockages have on a needle trajectory can be conducted to optimize the insertion accuracy. A treatment planning system was developed to formulate and implement the 3D local treatment plan before the surgery, during the surgery, and after the surgery. Several experiments pertaining to both single-seed and multiple-seed dose distributions were conducted to verify the accuracy of the single-seed dose calculation module and 3D superposition dose calculation in the treatment planning system.
Similar content being viewed by others
References
Wallner K, Blasko JC, Dattoli M (2001) Prostate brachytherapy Made complicated, 2nd edn. Smart Medicine Press, Seattle
Holm HH, Gammelgaard J (1981) Ultrasonically guided precise needle placement in the prostate and the seminal vesicles. J Urol 125(3):385–387
Holm HH, Juul N, Pedersen JF et al (1983) Transperineal 125I seed implantation in prostatic cancer guided by transrectal ultrasonography. J Urol 130(2):283–286
Grimm PD, Blasko JC, Sylvester JE et al (2001) 10-year biochemical (prostate-specific antigen) control of prostate cancer with 125I brachytherapy. Int J Radiat Oncol Biol Phys 51(1):31–40
Merrick GS, Butler WM, Galbreath RW et al (2001) Five-year biochemical outcome following permanent interstitial brachytherapy for clinical T1-T3 prostate cancer. Int J Radiat Oncol Biol Phys 51(1):41–48
Schlaefer A, Viulet T, Muacevic A et al (2013) Multicriteria optimization of the spatial dose distribution. Med Phys 40(12):121720–121730
Nath R, Anderson LL, Luxton G et al (1995) Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 22(2):209–234
Rivard MJ, Coursey BM, DeWerd LA et al (2004) Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations. Med Phys 31(3):633–674
Chibani O, Williamson JF, Todor D (2005) Dosimetric effects of seed anisotropy and interseed attenuation for Pd103 and I125 prostate implants. Med Phys 32(8):2557–2566
Pelowitz DG (2005) MCNPX user’s manual, version 2.5.0. EPA/600/R-05/040, US Environmental Protection Agency, National Risk Management Research Laboratory
Kitware (2010) The VTK user’s guide
Duan Y, Zhang M, Wang G et al (2012) Experimental determination of dosimetry parameters for Sinko 125I seed source using a modified polystyrene phantom. Australas Phys Eng Sci Med 35(3):291–296
Dempsey C (2010) Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning. Australas Phys Eng Sci Med 33(4):341–349
Schmid M, Crook JM, Batchelar D et al (2012) A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants. Brachytherapy 12(1):56–64
Melhus CS, Rivard MJ (2006) Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for Cs137, I125, Ir192, Pd103, and Yb169 sources. Med Phys 33(6):1729–1737
Mason J, Al-Qaisieh B, Bownes P et al (2013) Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET. Med Phys 40(3):031717–031726
Acknowledgements
This study was supported by the National Natural Science Foundation of China (no. 51175373) and the Key Technology and Development Program of the Tianjin Municipal Science and Technology Commission (no. 14ZCDZGX00490).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zhang, S., Jiang, S., Yang, Z. et al. Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy. Trans. Tianjin Univ. 24, 73–81 (2018). https://doi.org/10.1007/s12209-017-0080-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12209-017-0080-z