Abstract
Based on the investigation of fiber influence on workability of self-compacting concrete (SCC), tests were carried out on two series of SCC rectangular simply supported beams, which were made of hooked steel fibers reinforced concrete with or without stirrups, subjected to four-point symmetrically placed vertical loads. The major test variables are steel fiber contents and stirrup ratios. The results indicate that the ultimate load significantly increases with the increase of fiber content; the addition of steel fibers in adequate percentage can change the failure mode from a brittle shear collapse into a ductile flexural mechanism. The stirrups can be partially replaced by steel fibers. The combination of stirrups and steel fibers demonstrated a positive hybrid effect on the mechanical behavior.
Similar content being viewed by others
References
Prodromos D Zararis, George Ch Papadakis. Diagonal shear failure and size effect in RC beams without web reinforcement[ J]. Journal of Structural Engineering, 2001, 127(7): 733–742.
Calogero Cucchiara, Lidia La Mendola, Maurizio Papia. Effectiveness of stirrups and steel fibers as shear reinforcement[ J]. Cement & Concrete Composites, 2004, 26: 777–786.
Kwak Yoon-Keun, Eberhard Marc O, Kim Woo-Suk et al. Shear strength of steel fiber-reinforced concrete beams without stirrups[J]. ACI Structural Journal, 2002, 99(4): 530–537.
Russo G, Somma G, Angeli P. Design shear strength formula for high strength concrete beams[J]. Materials and Structures, 2004, 37: 680–688.
Zhang Hongzhan, Huang Chengkui. Experimental study on shear resistance of steel fiber reinforced high strength concrete beams[J]. Journal of Harbin Institute of Technology, 2006, 38(10): 1781–1785 (in Chinese).
Plizzari G A, Tiberti G. Steel fibers as reinforcement for precast tunnel segments[J]. Tunnelling and Underground Space Technology, 2006, 21: 438–439.
Choulli Youssef, Marí Antonio R, Cladera Antoni. Shear behaviour of full-scale prestressed i-beams made with self compacting concrete[J]. Materials and Structures, 2008, 41(1): 131–141.
Greenough Tom, Nehdi Moncef. Shear behavior of fiber-reinforced self-consolidating concrete slender beams[J]. ACI Materials Journal, 2008, 105(5): 468–477.
National Standard of the People’s Republic of China. GB 50010-2002, Code for Design of Concrete Structures[S]. China Architecture and Building Press, Beijing, 2002(in Chinese).
National Standard of the People’s Republic of China. GB50152-92, Test Methods of Concrete Structures[S]. China Architecture and Building Press, Beijing, 1992(in Chinese).
Ding Yining, Wang Yuehua, Dong Xiangjun. An investigation on the workability of fiber reinforced self-compacting high performance concrete[J]. China Civil Engineering Journal, 2005, 38(11): 51–57 (in Chinese).
Liu Siguo, Ding Yining. Study on early age restrained shrinkage of fiber reinforced self-compacting concrete [J]. Journal of Building Materials, 2008, 11(1): 8–13 (in Chinese).
EFNARC. Specification and Guidelines for Self-Compacting Concrete[S]. 2002.
The SCC European Project Group. The European Guidelines for Self-Compacting Concrete-Specification, Production and Use[S]. 2005.
Brite EuRam. Task 9 End Product-SCC Guidelines[S]. 2000.
ACI Committee 318, ACI 318-05, Building Code Requirements for Reinforced Concrete and Commentary (318R-05)[S]. American Concrete Institute, Farmington Hills, MI, 2005: 430.
Author information
Authors and Affiliations
Corresponding author
Additional information
Supported by National Natural Science Foundation of China (No. 50578026).
YOU Zhiguo, born in 1981, male, Dr.
Rights and permissions
About this article
Cite this article
You, Z., Ding, Y. & Niederegger, C. Replacing stirrups of self-compacting concrete beams with steel fibers. Trans. Tianjin Univ. 16, 411–416 (2010). https://doi.org/10.1007/s12209-010-1416-0
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12209-010-1416-0