Skip to main content
Log in

Model of current threshold for perception in testing electrical safety performance

  • Published:
Transactions of Tianjin University Aims and scope Submit manuscript

Abstract

A generalized mathematical model of human body current threshold for perception was established and the current flowing through human body could be arbitrary cyclical waveforms. The relationship between human body current threshold for perception and current frequency, true root mean square (RMS) value and influence factor was described. A test system was established based on electroencephalogram (EEG) to study the relationship between human body current threshold for perception and current waveform, frequency and duty cycle so that the data could be obtained objectively and reliably. At least 850 groups of current threshold for perception and 16-lead EEGs were acquired. The theoretical analysis are verified by experimental data, and an amendment proposal on leakage current evaluation limits specified in International Electro-Technical Commission (IEC) standards is suggested.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. IEC. IEC/TS 60479-1. Effects of Current on Human Beings and Livestock (Part 1): General Aspects[S]. The United States: International Electro-Technical Commission, 2005.

  2. IEC. IEC 479-2. Effects of Current Passing Through the Human Body[S]. The United States: International Electro-Technical Commission, 1987.

  3. Leitgeb N, Schroettner J, Cech R. Electric current perception of the general population including children and the elderly[J]. Medical Engineering and Technology, 2005, 29(5): 215–218.

    Article  Google Scholar 

  4. Leitgeb N, Schroettner J, Cech R. Electric current perception of children: The role of age and gender[J]. Medical Engineering and Technology, 2006, 30(5): 306–309.

    Article  Google Scholar 

  5. Osamu Ukimura, So Ushijima, Hisashi Honio et al. Neuroselective current perception threshold evaluation of bladder mucosal sensory function[J]. European Urology, 2004, 45(1): 70–76.

    Article  Google Scholar 

  6. IEC. IEC 60990 Methods of Measurement of Touch-Current and Protective Conductor Current[S]. The United States: International Electro-Technical Commission, 1999.

  7. Leonard Eisner, Robert M Brown, Dan Modi. Leakage current standards simplified[J]. Medical Device and Diagnostic Industry, 2004, 7: 32–37.

    Google Scholar 

  8. Hu Ruifen. Single-Trial Analysis of Current Evoked Event-Related Potentials[D]. College of Biomedical Engineering and Instrument Science, Zhejiang University, 2007(in Chinese).

  9. Liu Shilong, Yao Haifeng, Hu Guiquan et al. Research and development of a quantitative human current perception threshold testing system[J]. Chinese Journal of Medical Physics, 2003, 20(3): 173–175(in Chinese).

    Google Scholar 

  10. Le Yanfei, Li Yan, Li Guang et al. Development of a novel method to determine human current perception threshold[C]. In: Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005. Shanghai, China, 2005. 7513–7516.

  11. Ning Hao, Wang Xuemin, Zhang Xi. Effect of low frequency electrical stimulation on human nerve excitability[J]. Chinese Medical Equipment Journal, 2007, 28(7): 80–81(in Chinese).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiaofei Wang  (王晓飞).

Additional information

Supported by the Ministry of Science and Technology of China (No. NCSTE-2006-JKZX-167) and Beijing Key Laboratory (Measurement and Control of Electro-mechanical Systems) (No. 82063005).

WANG Xiaofei, born in 1965, Dr, associate Prof.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wang, X., Zhang, Z., Li, D. et al. Model of current threshold for perception in testing electrical safety performance. Trans. Tianjin Univ. 16, 11–16 (2010). https://doi.org/10.1007/s12209-010-0003-8

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12209-010-0003-8

Keywords

Navigation