Measurements of air temperature distribution and optimum cooling condition inside the computer system

  • Published:
Journal of Mechanical Science and Technology Aims and scope Submit manuscript

Abstract

Measurements of the temperature distributions of the cooling air flow inside a computer system have been made. An investigation of the optimum cooling condition for the computer system has also been made. Seventy-one K-type (Chromega-Alumega) thermocouples were used to measure distributions of the air flow temperature inside the computer system. They were calibrated against the standard platinum resistance thermometer (PRT) in a constant water circulating bath within an accuracy of ± 0.15 °C. It was found that the number and position of cooling fans as well as their operating condition, whether air intake or air discharge, can greatly influence the cooling effectiveness in the computer system. The results show that the flow rate of intake air should not be higher than that of the discharge air for the most effective cooling. It follows that the optimum cooling has been achieved inside the computer when the three fans are positioned in the inlet front, outlet back, and outlet top in the computer, respectively. Under these conditions, not only is the average temperature inside the computer system maintained at an appropriate level, but the most effective cooling around the central processor (CPU) and graphic card which are responsible for the largest amount of heat dissipation can be accomplished.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. van Ballegoie, Fast graphics-Cooling, (2000) 104.

  2. S. S. Lee, Zero & One, Hello PC, (July, 2000).

  3. D. H. Min, HDD and VGA Cooling Solution, Korea Benchmark, (February, 2000).

  4. S. Y. Won, How to Solve Heat Problems?, Korea Benchmark, (February, 2001).

  5. V. G. Pastukhov and Y. F. Maydanik, Low-noise cooling system for PC on the base of loop heat pipes, J. Appl. Thermal Eng., 27 (2007) 894–901.

    Article  Google Scholar 

  6. B. S. Kim, Air Flow and Temperature in Case, PCLine, (March, 1999) 260.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dae Hee Lee.

Additional information

This paper was recommended for publication in revised form by Associate Editor Man-Yeong Ha

Dae Hee Lee received a B.S. degree in Mechanical Engineering from Hanyang University in 1984. He then went on to receive his M.S. and Ph.D. degrees from University of California at Davis in 1984 and 1987, respectively. Dr. Lee is currently a Professor at the School of Mechanical Engineering and a Dean of Academic Affairs at Inje University in Korea. Dr. Lee’s research interests are in the area of Convection Heat Transfer, Liquid Crystal Thermography, Co-generation, and Renewable Energy.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, D.H., Jo, M.C., Lee, J.S. et al. Measurements of air temperature distribution and optimum cooling condition inside the computer system. J Mech Sci Technol 23, 544–549 (2009). https://doi.org/10.1007/s12206-008-1203-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12206-008-1203-1

Keywords

Navigation