Abstract
A novel self-centering frame with Y-eccentrically braced structure (SC-YEBFs) has been proposed in this paper to solve the problem that the storey drift of structure may exceed the specified limit in standards when self-centering beam-column joints are applied in high-rise and larger spans buildings, and the SC-YEBFs not only has the self-centering performance of self-centering frame system, but also has the high lateral stiffness and energy dissipating capacity of Y-Eccentrically braced frame. To study the lateral load behavior and influencing factors of SC-YEBFs, cyclic loading tests of two scaled specimens of SC-YEBFs substructure (SCS) were conducted, and seven finite element models corrected by the experiment were established to perform parametric analysis. The experiment and finite element analysis results indicated that the shear link has greatly increased the lateral stiffness and energy dissipating capacity of the self-centering structure, at the same time, it has maintained a good self-centering performance and replace ability. With an increase in the cross-sectional area and initial prestress of post-tensioned steel strands, the lateral load capacity and self-centering performance can be improved. The self-centering performance can be effectively improved by reducing the friction coefficient at the rotation connections. SC-YEBFs further extending the application field of self-centering structural systems, and making it possible to be applied to high-rise and larger spans structures.
Similar content being viewed by others
References
Abdulhameed AA, Said AI (2019) Experimental investigation of the behavior of self-form segmental concrete masonry arches. Fibers 7(7):58, DOI: https://doi.org/10.3390/fib7070058
ANSI/AISC (2005) Seismic provisions for structural steel buildings. Chicago (IL). American Institute of Steel Construction
Chaudhary MT, Piracha A (2021) Natural disasters—origins, impacts, management. Encyclopedia 1(4):1101–1131, DOI: https://doi.org/10.3390/encyclopedia1040084
Christopoulos C, Filiatrault A, Uang C-M, Folz B (2002) Posttensioned energy dissipating connections for moment-resisting steel frames. Journal of Structural Engineering 128(9):1111–1120, DOI: https://doi.org/10.1061/(asce)0733-9445(2002)128:9(1111)
Cimellaro GP, Renschler C, Reinhorn AM, Arendt L (2016) Peoples: A framework for evaluating resilience. Journal of Structural Engineering 142(10):04016063, DOI: https://doi.org/10.1061/(asce)st.1943-541x.0001514
Clayton PM, Berman JW, Lowes LN (2012) Seismic design and performance of self-centering steel plate shear walls. Journal of Structural Engineering 138(1):22–30, DOI: https://doi.org/10.1061/(asce)st.1943-541x.0000421
Clayton PM, Berman JW, Lowes LN (2013) Subassembly testing and modeling of self-centering steel plate shear walls. Engineering Structures 56:1848–1857, DOI: https://doi.org/10.1016/j.engstruct.2013.06.030
Clayton PM, Berman JW, Lowes LN (2015) Seismic performance of self-centering steel plate shear walls with beam-only-connected web plates. Journal of Constructional Steel Research 106:198–208, DOI: https://doi.org/10.1016/j.jcsr.2014.12.017
Dowden DM, Clayton PM, Li C-H, Berman JW, Bruneau M, Lowes LN, Tsai K-C (2016) Full-scale pseudodynamic testing of self-centering steel plate shear walls. Journal of Structural Engineering 142(1), DOI: https://doi.org/10.1061/(asce)st.1943-541x.0001367
Dyanati M, Huang Q, Roke D (2015) Seismic demand models and performance evaluation of self-centering and conventional concentrically braced frames. Engineering Structures 84:368–381, DOI: https://doi.org/10.1016/j.engstruct.2014.11.036
Garlock M, Ricles JM, Sause R, Peng SW, Zhao C, Lu LW (1998) Post-tensionedseismic resistant connections for steel frames, Structural Stability Research Council Conference Workshop, Rolla Missouri: Structural Stability Research Council
Garlock MM, Ricles JM, Sause R (2003) Cyclic load tests and analysis of bolted top-and-seat angle connections. Journal of Structural Engineering 129(12):1615–1625, DOI: https://doi.org/10.1061/(asce)0733-9445(2003)129:12(1615)
Garlock MM, Ricles JM, Sause R (2005) Experimental studies of full-scale posttensioned steel connections. Journal of Structural Engineering 131(3):438–448, DOI: https://doi.org/10.1061/(asce)0733-9445(2005)131:3(438)
Garlock MM, Ricles JM, Sause R (2008) Influence of design parameters on seismic response of post-tensioned steel MRF Systems. Engineering Structures 30(4):1037–1047, DOI: https://doi.org/10.1016/j.engstruct.2007.05.026
Hason MM, Al-Zuhairi AH, Hanoon AN, Abdulhameed AA, Al Zand AW, Abbood IS (2022) Peak ground acceleration models predictions utilizing two metaheuristic optimization techniques. Latin American Journal of Solids and Structures 19(3), DOI: https://doi.org/10.1590/1679-78256940
Hu X, Lu C, Zhu X, Xie X (2020a) A theoretical study of estimating the elastic responses of framed self-centering wall structures under lateral loading. KSCE Journal of Civil Engineering 24(12):3714–3725, DOI: https://doi.org/10.1007/s12205-020-2061-3
Hu SJ, Zeng SZ, Xiong JG, Wang XF (2020b) Seismic analysis and evaluation of Y-shaped EBF with an innovative SSL-SSBC. International Journal of Steel Structures 20(2):1026–1039, DOI: https://doi.org/10.1007/s13296-020-00340-6
Jahangiri A, Behnamfar F, Jahangiri M (2016) Introducing the innovative post-tensioned connection with the rigid steel node. KSCE Journal of Civil Engineering 21(4):1247–1255, DOI: https://doi.org/10.1007/s12205-016-0655-6
Jason M, Hiroshi A, Masahiro I (2008) Permissible residual deformation levels for building structures considering both safety and human elements. In: The 14th World Conference on Earthquake Engineering (WCEE), October 12–17, Beijing, China, DOI: https://doi.org/10.3969/j.issn.0253-.74x.2011.04.001
Ji XD, Wang YD, Ma QF, Okazaki T (2015) Cyclic behavior of very short steel shear links. Journal of Structural Engineering, ASCE 142(2):04015114–1–10, DOI: https://doi.org/10.1061/(ASCE)ST.1943-541X.0001375
Lin Y-C (2015) Steel sliding-controlled coupled beam modules: Development and seismic behavior for a moment resisting frame. Engineering Structures 99:726–736, DOI: https://doi.org/10.1016/j.engstruct.2015.05.008
Lin Y-C, Richard S, James MR (2013) Seismic performance of steel self-centering, moment-resisting frame: Hybrid simulations under design basis earthquake. Journal of Structural Engineering 139(11): 1823–32, DOI: https://doi.org/10.1061/(asce)st.1943-541x.0000745
Lin Y-C, Ricles J, Sause R, Seo C-Y (2009) Earthquake simulations on a self-centering steel moment resisting frame with web friction devices. Structures Congress, DOI: https://doi.org/10.1061/41031(341)149
Ma K, Ye X, Yu H, Wu R, Li Y, Li W (2023) Study on seismic behavior and influencing factors of composite connection in moment-resisting steel frame. KSCE Journal of Civil Engineering 27(3): 1093–1106, DOI: https://doi.org/10.1007/s12205-023-2100-y
O’Reilly GJ, Goggins J (2021) Experimental testing of a self-centring concentrically braced steel frame. Engineering Structures 238, DOI: https://doi.org/10.1016/j.engstruct.2020.111521
Pollino M (2015) Seismic design for enhanced building performance using rocking steel braced frames. Engineering Structures 83:129–139, DOI: https://doi.org/10.1016/j.engstruct.2014.11.005
Ricles JM, Sause R, Garlock M, Zhao C (2001) Post-tensioned seismic-resistant connections for steel frames. Journal of Structural Engineering 127(2):113–21
Ricles JM, Sause R, Peng SW, Lu LW (2002) Experimental evaluation of earthquake resistant posttensioned steel connections. Journal of Structural Engineering 128(7):850–859, DOI: https://doi.org/10.1061/(asce)0733-9445(2002)128:7(850)
Rojas P, Ricles JM, Sause R (2005) Seismic performance of post-tensioned steel moment resisting frames with friction devices. Journal of Structural Engineering 131(4):529–540, DOI: https://doi.org/10.1061/(asce)0733-9445(2005)131:4(529)
Wilkinson S, Free M, Grant D, Boon D, Paganoni S, Mason A, Williams E, Fraser S, Haskell J (2011) Damage Survey of the 2011 christchurch, new zealand earthquake. A FIELD REPORT BY EEFIT
Xiong J, Chen W, Hu S, Wang X, Zeng S (2019) Study of optimum design method for Y-shaped EBFs based on energy balance theory and energy dissipation coefficient. Journal Nanchang University (Natural Science) (3):284–289+295, DOI: https://doi.org/10.13764/j.cnki.ncdl.2019.03.015 (in Chinese)
Zhang A, Zhang Y, Liu A, Shao D, Li Q (2019) Performance study of self-centering steel frame with intermediate columns containing friction dampers. Engineering Structures 186:382–98, DOI: https://doi.org/10.1016/j.engstruct.2019.02.023
Zhang AL, Zhang YX, Li R, Wang Z.-Y (2016) Cyclic behavior of a prefabricated self-centering beam–column connection with a bolted web friction device. Engineering Structures 111:185–98, DOI: https://doi.org/10.1016/j.engstruct.2015.12.025
Zhao J, Yu H, Pan Y, Chen R, Guo R (2019) Seismic performance of sliding gusset connections in buckling-restrained braced steel frame. Journal of Building Structures 40(2):117–127, DOI: https://doi.org/10.14006/j.jzjgxb.2019.02.010 (in Chinese)
Acknowledgments
The authors gratefully acknowledge the research grant provided by the National Nature Science Foundation of China (No. 52068051).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xiong, J., Xiong, M., Liu, Y. et al. Lateral Load Behavior of Self-centering Frame with Y-Eccentrically Braced Substructure: An Experiment and Numerical Analysis. KSCE J Civ Eng 28, 715–731 (2024). https://doi.org/10.1007/s12205-023-0208-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-023-0208-8