Abstract
The bonding behavior of reinforcing bars embedded in Ultra-high Strength Concrete (UHSC) with steel fibers is discussed. Ten steel-fiber-reinforced UHSC specimens including three UHSC beams and seven lap-spliced UHSC beams were fabricated to investigate the bonding behavior. The compressive strengths of these specimens ranged from 130 to 150 MPa along with volume of steel fibers from 0 to 2%. The tensile behavior enhanced by different amounts of steel fibers was also compared using small-scale bending tests. In the UHSC beam tests, considerable bonding strength was identified in that the specimen with a lap-splice length of 10 db exhibited flexural responses equivalent to those from the specimen without lap splices. In addition, the ductile failure was ensured when a moderate amount of steel fibers was incorporated by compensating the brittleness of UHSC. These experimental results indicate that remarkably short splice length is applicable to the UHSC structure by incorporating sufficient amount of steel fibers.
Similar content being viewed by others
References
ASTM C1609/C1609M-06 (2006). “Standard test method for flexural performance of fiber-reinforced concrete (Using Beam with Third-Point Loading).” ASTM International, West Conshohocken, PA, DOI: 10.1520/C1609_C1609M-12.
Azizinamini, A., Pavel, R., Hatfield, E., and Ghosh, S. K. (1999). “Behavior of lap-spliced reinforcing bars embedded in high-strength concrete.” ACI Structural Journal, Vol. 96, No. 5, pp. 826–835, DOI: 10.14359/737.
Azizinamini, A., Stark, M., Roller, J. J., and Ghosh, S. K. (1993). “Bond performance of reinforcing bars embedded in high-strength concrete.” ACI Structural Journal, Vol. 90, No. 5, pp. 554–561, DOI: 10.14359/3951.
Azizinmini A., Chisala M., and Ghosh S. K. (1995). “Tension development length of reinforcing bars embedded in high-strength concrete.” Engineering Structures, Vol. 17, No. 7, pp. 512–522, DOI: 10.1016/0141-0296(95)00096-P.
Chao, S. H., Naaman, A. E., and Parra-Montesinos, G. J. (2009). “Bond behavior of reinforcing bars in tensile strain-hardening fiber-reinforced cement composite.” ACI Structural Journal, Vol. 106, No. 6, pp. 887–906, DOI: 10.14359/51663191.
Eurocode 2 (2004). Design of concrete structures, Part 1-1: General rules and rules for buildings, BS EN 1992-1- 1, British Standard.
Holschemacher, K., Weiße, D., and Klotz, S. (2005). “Bond of reinforcement in ultra high-strength concrete.” ACI Special Publication, SP 228-34, pp. 513–528.
Jungwirth, J. and Muttoni, A. (2004). “Structural behavior of tension members in ultra high performance concrete.” International Symposium on Ultra High Performance Concrete. Kassel, Germany, pp. 533–544.
Oesterlee, C. (2010). Structural response of reinforced uhpfrc and rc composite members, PhD Thesis, École Polytechnique Fédérale de Lausanne, DOI: 10.5075/epfl-thesis-4848.
Wight, J. K. and MacGregor, J. G. (2009). Reinforced concrete mechanics and design 5th Ed., Prentice Hall: New Jersey.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lee, JK. Bonding behavior of lap-spliced reinforcing bars embedded in Ultra-high Strength Concrete with steel fibers. KSCE J Civ Eng 20, 273–281 (2016). https://doi.org/10.1007/s12205-015-1396-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-015-1396-7