Skip to main content

Evaluation of a Novel Multimodal Guidance Device for Difficult Airway Endotracheal Intubation in Spontaneously Breathing Pigs

Abstract

End-expiratory carbon dioxide concentrations can be used to assist endotracheal intubation. The novel multimodal endotracheal intubation guidance device combined visualization with an end-expiratory carbon dioxide concentration vectorization algorithm to achieve more accurate placement in difficult airways. The feasibility of a novel multimodal guidance device for the endotracheal intubation of difficult airways was verified in spontaneously breathing Bama miniature pigs. The glottic exposure time, insertion time, and total intubation time were not significantly different between the fiberoptic bronchoscope group and the multimodal guidance device group in regard to the endotracheal intubation of difficult airways. There were also no significant differences in intubation attempts, first success rate, and total success rate. Animals in both groups experienced hypoxemia, hypotension, and esophageal intubation during endotracheal intubation, but there were also no significant differences in the incidence of adverse events between the two devices. The effect on changes in hemodynamics, heart rate, and oxygen saturation during intubation showed no significant difference between the two devices. The results of the present study demonstrated the feasibility and effectiveness of the initial prototype of a multimodal guidance device for the endotracheal intubation of difficult airways in pigs, which is expected to further assist in adequately positioning the airway during difficult endotracheal intubations with spontaneous breathing.

This is a preview of subscription content, access via your institution.

References

  1. [1]

    COOK T M, SCOTT S, MIHAI R. Litigation related to airway and respiratory complications of anaesthesia: An analysis of claims against the NHS in England 1995–2007 [J]. Anaesthesia, 2010, 65(6): 556–563.

    Article  Google Scholar 

  2. [2]

    WHITLOCK E L, FEINER J R, CHEN L L. Perioperative mortality, 2010 to 2014: A retrospective cohort study using the national anesthesia clinical outcomes registry [J]. Anesthesiology, 2015, 123(6): 1312–1321.

    Article  Google Scholar 

  3. [3]

    APFELBAUM J L, HAGBERG C A, CAPLAN R A, et al. Practice guidelines for management of the difficult airway: An updated report by the American society of anesthesiologists task force on management of the difficult airway [J]. Anesthesiology, 2013, 118(2): 251–270.

    Article  Google Scholar 

  4. [4]

    MURPHY T, HOWES B. Current practice for awake fibreoptic intubation — some unanswered questions [J]. Anaesthesia, 2017, 72(6): 678–681.

    Article  Google Scholar 

  5. [5]

    MOORE A, SCHRICKER T. Awake videolaryngoscopy versus fiberoptic bronchoscopy [J]. Current Opinion in Anaesthesiology, 2019, 32(6): 764–768.

    Article  Google Scholar 

  6. [6]

    LINKO K, PALOHEIMO M. Capnography facilitates blind nasotracheal intubation [J]. Acta Anaesthesiologica Belgica, 1983, 34(2): 117–122.

    Google Scholar 

  7. [7]

    LEE L Y, LEE D, RYU H, et al. Capnography-guided endotracheal intubation as an alternative to existing intubation methods in rabbits [J]. Journal of the American Association for Laboratory Animal Science, 2019, 58(2): 240–245.

    Article  Google Scholar 

  8. [8]

    JANISZEWSKI A, PASWSKI R, SKRZYPCZAK P, et al. The use of a plastic guide improves the safety and reduces the duration of endotracheal intubation in the pig [J]. The Journal of Veterinary Medical Science, 2014, 76(10): 1317–1320.

    Article  Google Scholar 

  9. [9]

    DUKE-NOVAKOVSKI T, AMBROS B, AUCKLAND C D, et al. The effects of succinylcholine or low-dose rocuronium to aid endotracheal intubation of adult sows [J]. Canadian Journal of Veterinary Research, 2012, 76(1): 57–61.

    Google Scholar 

  10. [10]

    HUH H, LIM H H, KIM J Y, et al. A novel and simple method for tracheal intubation in a swine model: Preparing for the era of xenotransplantation [J]. Experimental and Clinical Transplantation, 2017, 15(4): 453–457.

    Google Scholar 

  11. [11]

    RUEMMLER R, ZIEBART A, OTT T, et al. Flexible fibreoptic intubation in swine — improvement for resident training and animal safety alike [J]. BMC Anesthesiology, 2020, 20(1): 206.

    Article  Google Scholar 

  12. [12]

    BIRO P, HOFMANN P, GAGE D, et al. Automated tracheal intubation in an airway manikin using a robotic endoscope: A proof of concept study [J]. Anaesthesia, 2020, 75(7): 881–886.

    Article  Google Scholar 

  13. [13]

    HSU C, LIN H, WU Y, et al. Assessment of a new method to distinguish esophageal from tracheal intubation by measuring the endotracheal cuff pressure in a porcine model [J]. Annals of Emergency Medicine, 2004, 44(4): S119.

    Article  Google Scholar 

  14. [14]

    LOCKEY D J, AVERY P, HARRIS T, et al. A prospective study of physician pre-hospital anaesthesia in trauma patients: Oesophageal intubation, gross airway contamination and the ‘quick look’ airway assessment [J]. BMC Anesthesiology, 2013, 13(1): 21.

    Article  Google Scholar 

  15. [15]

    HUNT K A, YAMADA Y, MURTHY V, et al. Detection of exhaled carbon dioxide following intubation during resuscitation at delivery [J]. Archives of Disease in Childhood Fetal and Neonatal Edition, 2019, 104(2): F187–F191.

    Article  Google Scholar 

  16. [16]

    BLACKBURN M B, NAWN C D, RYAN K L. Testing of novel spectral device sensor in swine model of airway obstruction [J]. Physiological Reports, 2019, 7(19): e14246.

    Article  Google Scholar 

  17. [17]

    KUGELMAN A, ZEIGER-AGINSKY D, BADER D, et al. A novel method of distal end-tidal CO2 capnog-raphy in intubated infants: Comparison with arterial CO2 and with proximal mainstream end-tidal CO2 [J]. Pediatrics, 2008, 122(6): e1219–e1224.

    Article  Google Scholar 

  18. [18]

    BALOGH A L, PETAK F, FODOR G H, et al. Capnogram slope and ventilation dead space parameters: Comparison of mainstream and sidestream techniques [J]. British Journal of Anaesthesia, 2016, 117(1): 109–117.

    Article  Google Scholar 

Download references

Author information

Affiliations

Authors

Corresponding author

Correspondence to Hong Jiang.

Additional information

Foundation item: the Interdisciplinary Program of Shanghai Jiao Tong University (No. ZH2018ZDA14) and the Clinical Research Plan of the Shenkang Hospital Development Center (No. SHDC2020CR3043B)

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Xia, M., Xu, T., Cao, S. et al. Evaluation of a Novel Multimodal Guidance Device for Difficult Airway Endotracheal Intubation in Spontaneously Breathing Pigs. J. Shanghai Jiaotong Univ. (Sci.) (2021). https://doi.org/10.1007/s12204-021-2330-4

Download citation

Key words

  • endotracheal intubation
  • autonomous respiration
  • end-expiratory carbon dioxide
  • multimodal guidance device
  • airway management

CLC number

  • R 4
  • R 197.39

Document code

  • A