Research on Time-Domain Transfer Impedance Measurement Technology for High Frequency Current Transformers in Partial Discharge Detection of Cables

  • Published:
Journal of Shanghai Jiaotong University (Science) Aims and scope Submit manuscript

Abstract

We focus on the high frequency current method which is widely applied in the partial discharge (PD) detection of cables. Aiming at guaranteeing the accuracy of this method, we study an innovative time-domain technology for effectively measuring the transfer impedance of the high frequency current transformers (HFCTs). The proposed technology called pulse injection method obtains the system response under the excitation of the wide-band instantaneous pulse signal. Firstly, by studying the working principle of HFCTs, we summarize that the bandwidth of the selected signal acquisition device should be at least 100MHz to ensure measurement accuracy. Secondly, Gauss pulse and square wave pulse are generated to determine the effects of different sources. The measurement results indicate that Gauss pulse is more suitable for pulse injection method, and the rise time should be under 10 ns to improve the starting frequency of oscillation distortion. Finally, the transfer impedance curves of five types of HFCTs are acquired by both pulse injection and traditional point-frequency methods. The measurement results show a remarkable consistency between two methods. However, pulse injection method requires the simpler operation and has a higher resolution, obviously improving the measurement efficiency and better displaying the details of the transfer impedance curves.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. EIGNER A, RETHMEIER K. An overview on the current status of partial discharge measurements on APC high voltage cable accessories [J]. IEEE Electrical Insulation Magazine, 2016, 32(2): 48–55.

    Article  Google Scholar 

  2. WILD M, TENBOHLEN S, GULSKI E, et al. Basic aspects of partial discharge on-site testing of long length transmission power cables [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2017, 24(2): 1077–1087.

    Article  Google Scholar 

  3. JIANG X C, CAI J, DONG X B, et al. On-line monitoring techniques for 110 kV and above XLPE cable [J]. Electric Power Automation Equipment, 2005, 25(8): 13–17 (in Chinese).

    Google Scholar 

  4. ZHUH G, FENG J, LUO JH. Study on PD HF detection technology of XLPE power cable [J]. High Voltage Engineering, 2004, 30(136): 75–76 (in Chinese).

    Google Scholar 

  5. TIAN Y, LEWIN P L, DAVIES A E, et al. Partial discharge detection in cables using VHF capacitive couplers [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(2): 343–353.

    Article  Google Scholar 

  6. WOUTERS P A A F, VAN DER LAAN P C T, STEENNIS E F. Inductive ultra-wide band detection and location of partial discharges in high-voltage cables [J]. European Transactions on Electrical Power Engineering, 1994, 4(3): 223–229.

    Article  Google Scholar 

  7. POMMERENKE D, STREHL T, HEINRICH R, et al. Discrimination between internal PD and other pulses using directional coupling sensors on HV cable systems [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1999, 6(6): 814–824.

    Article  Google Scholar 

  8. KATSUTA G, TOYA A, MURAOKA K, et al. Development of a method of partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines [J]. IEEE Transactions on Power Delivery, 1992, 7(3): 1068–1079.

    Article  Google Scholar 

  9. TANG J, LI W, YANG H, et al. Ultra-high frequency detection and analysis for partial discharge in highvoltage cable accessories [J]. High Voltage Engineering, 2009, 35(7): 1571–1577 (in Chinese).

    Google Scholar 

  10. GUO C X, ZHANG L, QIAN Y, et al. Current status of partial discharge detection and location techniques in XLPE power cable [J]. High Voltage Apparatus, 2009, 45(3): 56–60 (in Chinese).

    Google Scholar 

  11. State Grid Corporation of China. Technical specification for on line detection equipment of partial discharge for power cables: Q/GDW 11224–2014 [S]. (2014-12-01) [2019-09-06] (in Chinese).

  12. XU Y, GU X, LIU B, et al. Special requirements of high frequency current transformers in the on-line detection of partial discharges in power cables [J]. IEEE Electrical Insulation Magazine, 2016, 32(6): 8–19.

    Article  Google Scholar 

  13. CHEN X X, QIAN Y, XU Y P, et al. Characteristic admittance model and PD amplitude distribution of tunnel-installed high-voltage cables [J]. Electric Power Automation Equipment, 2017, 37(7): 171–177 (in Chinese).

    Google Scholar 

  14. State Grid Corporation of China. Technical specification for energized test device of electrical equipment. Part 5. Technical specification for high-frequency partial discharge detector: Q/GDW 11304.5-2015 [S]. (2015-11-07) [2019-09-06] (in Chinese).

  15. JUDD M D, FARISH O. A pulsed GTEM system for UHF sensor calibration [J]. IEEE Transactions on Instrumentation and Measurement, 1998, 47(4): 875–880.

    Article  Google Scholar 

  16. CHEN X X, QIAN Y, SHENG G H, et al. A timedomain characterization method for UHF partial discharge sensors [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2017, 24(1): 110–119.

    Article  Google Scholar 

  17. CHEN X, CHEN Y G, WEI M, et al. Time domain testing methods of material’s shielding effectiveness of electromagnetic pulse using flange coaxial [J]. High Voltage Engineering, 2012, 38(3): 594–600 (in Chinese).

    Google Scholar 

  18. HERLEMANN H, KOCH M. Measurement of the transient shielding effectiveness of enclosures using UWB pulses inside an open TEM waveguide [J]. Advances in Radio Science, 2007, 5(2): 75–79.

    Article  Google Scholar 

  19. ZHOU Y F, QIN Y, CHAPPELL P. Cost-effective online partial discharge of measurements for cables [J]. IEEE Electrical Insulation Magazine, 2006, 22(2): 31–38.

    Article  Google Scholar 

  20. ZHAO L J, HE J J, QIAN G J, et al. Research on wide band sensor for PD on-line monitoring [J]. High Voltage Engineering, 2005, 31(3): 46–47 (in Chinese).

    Google Scholar 

  21. MA C J, HUNAG X H, QIU Y C, et al. Optimization of the wide frequency bandwidth current transducer for PD detection [J]. High Voltage Apparatus, 2001, 37(1): 24–26 (in Chinese).

    Google Scholar 

  22. LIU M L, LU F M, ZHU J M, et al. Modern pulse metrology [M]. Beijing, China: Science Press, 2010 (in Chinese).

    Google Scholar 

  23. CHEN X X, QIAN Y, SHENG G H, et al. Study of UHF partial discharge sensor time domain parameters based on frequency domain deconvolution [J]. High Voltage Engineering, 201, 41(5): 1488–1494 (in Chinese)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yong Qian  (钱 勇).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Song, S., Chen, X., Qian, Y. et al. Research on Time-Domain Transfer Impedance Measurement Technology for High Frequency Current Transformers in Partial Discharge Detection of Cables. J. Shanghai Jiaotong Univ. (Sci.) 25, 10–17 (2020). https://doi.org/10.1007/s12204-020-2154-7

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12204-020-2154-7

Keywords

CLC number

Document code

Navigation