Abstract

Wireless capsule endoscopy (CE), an image inspection technique, has been an important advancement in the diagnosis of gastrointestinal (GI) tract diseases. A video capsule endoscopy (VCE) system is analyzed in this study. A complementary metal oxide semiconductor (CMOS) analog image sensor is adopted, and other illumination, communication and energy modules are designed for functional realization. Measuring only Ø11mm × 25 mm, the VCE has a total power consumption of 52.5 mW, which enables it to work continuously for 8 h. The in vivo experiment on a living pig indicates that a clear video with high frame rate of 30 f/s can be obtained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Iddan G, Meron G, Glukhovsky A, et al. Wireless capsule endoscopy [J]. Nature, 2000, 405(6785): 417.

    Article  Google Scholar 

  2. Eliakim R. Video capsule endoscopy of the small bowel [J]. Current Opinion in Gastroenterology, 2010, 26(2): 129.

    Article  Google Scholar 

  3. Chi B, Yao J, Han S, et al. Low-power transceiver analog front-end circuits for bidirectional high data rate wireless telemetry in medical endoscopy applications [J]. IEEE Transactions on Biomedical Engineering, 2007, 54(7): 1291–1299.

    Article  Google Scholar 

  4. Thoné J, Radiom S, Turgis D, et al. Design of a 2Mbps FSK near-field transmitter for wireless capsule endoscopy [J]. Sensors and Actuators A: Physical, 2009, 156(1): 43–48.

    Article  Google Scholar 

  5. Li X, Zhang M, Wang Z, et al. Smart image sensor with integrated low complexity image processing for wireless endoscope capsules [J]. Tsinghua Science & Technology, 2009, 14(5): 586–592.

    Article  MathSciNet  Google Scholar 

  6. Pan G, Xin W, Yan G, et al. A video wireless capsule endoscopy system powered wirelessly: Design, analysis and experiment [J]. Measurement Science and Technology, 2011, 22(6): 65802.

    Article  Google Scholar 

  7. Chiraw L C, Hammond P A, Roy S, et al. Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz [J]. IEEE Transactions on Biomedical Engineering, 2003, 50(4): 484–492.

    Article  Google Scholar 

  8. Kwak S I, Chang K, Yoon Y J. The helical antenna for the capsule endoscope [C]// In Proc IEEE Antennas and Propagation Society International Symposium. [s. l.]: IEEE, 2005: 804–807.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bing-quan Zhu  (朱柄全).

Additional information

Foundation item: the National Natural Science Foundation of China (No. 31170968), and the Shanghai Science Committee Foundation (No. 09DZ1907400)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhu, Bq., Yan, Gz., Liu, G. et al. A wireless video capsule endoscopy system: Design and realization. J. Shanghai Jiaotong Univ. (Sci.) 20, 649–653 (2015). https://doi.org/10.1007/s12204-015-1672-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12204-015-1672-1

Key words

CLC number

Navigation