Skip to main content
Log in

Protection distance of surge protective devices in low voltage distribution systems

  • Published:
Journal of Shanghai Jiaotong University (Science) Aims and scope Submit manuscript

Abstract

Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over-voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hasse P. Overvoltage protection of low voltage systems (2nd Ed) [M]. London, United Kingdom: Institution of Electrical Engineers, 2000.

    Google Scholar 

  2. IEC60664. Insulation coordination for equipments within low-voltage systems [S]. Geneva, Switzerland: International Electrotechnical Commission, 1992.

  3. IEEE C62.41-1991. Recommended practice on surge voltages in low-voltage ac power circuits [S]. New York: IEEE, 1991.

  4. IEC61643-12. Low-voltage surge protective devicespart 12: surge protective devices connected to lowvoltage power distribution systems-selection and applications principles [S]. Geneva, Switzerland: International Electrotechnical Commission, 2002.

  5. He Jinliang, Yuan Zhiyong, Xu Jing, et al. Evaluation of the effective protection distance of low-voltage SPD to equipment [J]. IEEE Trans on Power Delivery, 2005, 20(1): 122–130.

    Google Scholar 

  6. Hu Shousong. The principles of automatic control [M]. Beijing: Science Press, 2001 (in Chinese).

    Google Scholar 

  7. Zhu Zishu, Over-voltage in power systems [M]. Shanghai: Shanghai Jiaotong University Press, 1995 (in Chinese).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zheng-cai Fu  (傅正财).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhang, D., Fu, Zc., Zhao, G. et al. Protection distance of surge protective devices in low voltage distribution systems. J. Shanghai Jiaotong Univ. (Sci.) 13, 477–481 (2008). https://doi.org/10.1007/s12204-008-0477-x

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12204-008-0477-x

Key words

CLC number

Navigation