Abstract
A new method was developed for quantifying the accuracy limits of image registration devices and the distortion of anatomical structures in verification images without image registration. A correlation was found between peak signal-to-noise ratio (PSNR) and the amount of parallel movement (1–10 mm at 1-mm intervals) of a rectangular parallelepiped phantom [correlation coefficient (CC) −0.91, contribution ratio (CR) 0.83]. Rotating the phantom from 1° to 10° at 1° intervals produced a similar correlation with PSNR (CC −0.91, CR 0.83). To allow for manual registration, the grid pattern of the Mylar top plate was extracted from 455 pelvic portal images of 21 patients using a band-pass filtering technique. This revealed a different correlation between the original data (CC −0.62, CR 0.38) and averaged data (CC −0.96, CR 0.92), but this is considered to have been caused by structural distortion and manual matching errors. Thus, PSNR can be used to evaluate the accuracy limits of image registration and provide a judgment index that can be used in re-planning or re-setup in adaptive radiotherapy.
Similar content being viewed by others
References
Bissonnette JP, Balter PA, Dong L, Langen KM, Lovelock DM, et al. Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179. Med Phys. 2012;39(4):1946–63.
Motegi K, Kohno R, Ueda T, Shibuya T, Ariji T, et al. Evaluating positional accuracy using megavoltage cone-beam computed tomography for IMRT with head-and-neck cancer. Radiat Res. 2014;55(3):568–74.
Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. Clin Oncol. 2007;25(8):938–46.
De Los Santos J, Popple R, Agazaryan N, Bayouth JE, Bissonnette JP, et al. Radiation therapy (IGRT) technologies for radiation therapy localization and delivery. Rad Oncol. 2013;87(1):33–45.
Markelj P, Tomazevic D, Likar B, Pernus F. A review of 3D/2D registration methods for image-guided interventions. Med Image Anal. 2012;16(3):642–61.
Erminia I, Trodella L, Ramella S, D’Angelillo RM, et al. Estimation of patient setup uncertainty using BrainLAB exatrac X-Ray 6D system in image-guided radiotherapy. Med Phys. 2015;16(2):99–107.
Balter JM, Kessler ML. Imaging and alignment for image-guided radiation therapy. Clin Oncol. 2007;25(8):931–7.
Zhang L, Garden AS, Lo J, Ang KK, Ahamad A, et al. Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy. Rad Oncol Biol Phys. 2006;64(5):1559–69.
Pooja K, Yuvraj S. Comparison of different image enhancement techniques based upon PSNR & MSE. Appl Eng Res. 2012;7(11):2010–4.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Funding
This study was funded by a Kazuya Yamashita Grant of the Japanese Society of Radiological Technology (Grant Number 1).
Conflict of interest
The authors declare that they have no conflict of interest.
About this article
Cite this article
Tanabe, Y., Ishida, T. Quantification of the accuracy limits of image registration using peak signal-to-noise ratio. Radiol Phys Technol 10, 91–94 (2017). https://doi.org/10.1007/s12194-016-0372-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12194-016-0372-3