Maolinbay M, El-Mohri Y, Antonuk LE, Jee K-W, Nassif S, Rong X, et al. Additive noise properties of active matrix flat-panel imagers. Med Phys. 2000;27:1841–54.
CAS
Article
PubMed
Google Scholar
El-Mohri Y, Antonuk LE, Zhao Q, Maolinbay M, Rong X, Jee K-W, et al. A quantitative investigation of additive noise reduction for active matrix flat-panel imagers using compensation lines. Med Phys. 2000;27:1855–64.
CAS
Article
PubMed
Google Scholar
Zhao W, Rowlands JA. X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology. Med Phys. 1995;22:1595–604.
CAS
Article
PubMed
Google Scholar
Barrett HH, Swindell W. Radiological imaging. New York: Academic; 1981. p. 29–61.
Jaffe CC, Orphanoudakis SC, Ablow RC. The effect of a television digital noise reduction device on fluoroscopic image quality and dose rate. Radiology. 1982;144:789–92.
CAS
Article
PubMed
Google Scholar
Funama Y, Awai K, Miyazaki O, Nakayama Y, Goto T, Omi Y, et al. Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: evaluation with a computer-simulated liver including tumors. Invest Radiol. 2006;41:1–7.
Article
PubMed
Google Scholar
Sasaki T, Hanari T, Sasaki M, Oikawa H, Gakumazawa H, Okumura M, et al. Reduction of radiation exposure in CT perfusion study using a quantum de-noising filter. Jpn J Radiol Technol. 2004;60:1688–93 [in Japanese].
Google Scholar
Honda M, Shiraishi K. An image processing method for fluoroscopy using a linear shadow detection. Med Imaging and Inf Sci. 2004;21:239–51 [in Japanese].
Google Scholar
Saito N, Kudo K, Sasaki T, Uesugi M, Koshino K, Miyamoto M, et al. Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering. Radiol Phys Technol. 2008;1:62–74.
Article
PubMed
Google Scholar
Vuylsteke P, Dewaele P. Method and apparatus for noise reduction. US Patent 5,461,655;1995.
Yamada S, Murase K. Effectiveness of flexible noise control image processing for digital portal images using computed radiography. Br J Radiol. 2005;78:519–27.
CAS
Article
PubMed
Google Scholar
Nambu K, Iseki H. A noise reduction method based on a statistical test of high dimensional pixel vectors for dynamic and volumetric images. Riv Neuroradiol. 2005;18:21–33.
Article
Google Scholar
Samei E, Flynn MJ, Reimann DA. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Med Phys. 1998;25:102–13.
CAS
Article
PubMed
Google Scholar
Greer PB, Doorm TV. Evaluation of an algorithm for the assessment of the MTF using an edge method. Med Phys. 2000;27:2048–59.
CAS
Article
PubMed
Google Scholar
Medical diagnostic X-ray equipment—radiation conditions for use in the determination of characteristics. IEC Standard 61267;1994.
Medical electrical equipment—characteristics of digital X-ray imaging devices—part 1: Determination of the detective quantum efficiency. IEC Standard 62220-1;2003.
Dobbins III JT. Image quality metrics for digital systems. In: Beutel J, Kundel HL, Van Meter RL, editors. Handbook of medical imaging. Vol. 1: SPIE Press; 2000. p. 161–222.
Evaluation and routine testing in medical imaging departments—part 3-3: acceptance tests—imaging performance of X-ray equipment for digital subtraction angiography (DSA). IEC Standard 61223-3-3;1996.