Abstract
In this paper, a comparative study between three acid decomposition procedures of milk powder samples for the determination of Ca, Cu, Fe, K, and Na by optical emission spectrometry with inductively coupled plasma is presented. Utilizing a reflux system, it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, avoiding the loss of analyte and the excessive evaporation of the acids during the heating. Conditions of acidity (10 mL HNO3/H2SO4), temperature (350 °C), and decomposition time (4 h) were defined by evaluation of residual carbon content. Acid digestion in an open system with a cold finger was compared with a conventional open system (4 h ate 120 °C), as well as with microwave digestion (heating ramp to 180 °C by the time 45 min), for four commercial samples of milk powder. For the three sample preparation procedures, the values of the analyte concentrations in all analyzed samples were similar. The accuracy of the acid digestion procedures for Ca, Cu, Fe, K, and Na was assessed by the analysis of a certified reference material of milk (infant formula), and good agreement between the certified values and the measured value was obtained. The limits of quantification for the acid digestion with reflux system for Ca, Cu, Fe, K, and Na, in milligram per kilogram, were 7.48, 0.31, 1.0, 8.20, and 25.81, respectively, and for the microwave digestion were 14.0, 0.57, 1.78, 14.65, and 46.08, respectively. The decomposition procedure using a cold finger in an open system is effective, presenting the lowest residual carbon content (6 %), good accuracy, and relative standard deviation lower than 5 %, and appears to be a suitable procedure for sample preparation for routine analysis.
Similar content being viewed by others
References
Buldini PL, Cavalli S, Sharma JL (2002) Matrix removal for the ion chromatographic determination of some trace elements in milk. Microchem J 72:277–284
Castro JT, Santos EC, Santos WPC, Costa LM, Korn M, Nóbrega JA, Korn MGA (2009) A critical evaluation of digestion procedures for coffee samples using diluted nitric acid in closed vessels for inductively coupled plasma optical emission spectrometry. Talanta 78:1378–1382
Costa LM, Korn MGA, Castro JT, Santos WPC, Carvalho EV, Nogueira ARA (2006) Planejamento fatorial aplicado à digestão de amostras de feijão assistida por radiação micro-ondas. Quim Nov. 29:149–152
Fernandes TAP, Brito JAA, Gonçalves LML (2015) Analysis of micronutrients and heavy metals in Portuguese infant milk powders by wavelength dispersive X-ray fluorescence spectrometry (WDXRF). Food Anal Methods 8:52–57
Ferrão MF, Mello C, Borin A, Maretto DA, Poppi RJ (2007) LS-SVM: uma nova ferramenta quimiométrica para regressão multivariada. Comparação de modelos de regressão LS-SVM e PLS na quantificação de adulterantes em leite em pó empregando NIR. Quim Nov. 30:852–859
Ferreira SLC, Silva LOB, Santana FA, Junior MMS, Matos GD, Santos WNL (2013) A review of reflux systems using cold finger for sample preparation in the determination of volatile elements. Microchem J 106:307–310
Freschi GPG, Fortunato FM, Freschi CD, Neto JAG (2012) Simultaneous and direct determination of As, Bi, Pb, Sb, and Se and Co, Cr, Cu, Fe, and Mn in milk by electrothermal atomic absorption spectrometry. Food Anal Methods 5:861–866
Gouveia ST, Silva FV, Costa LM, Nogueira ARA, Nóbrega JA (2001) Determination of residual carbon by inductively coupled plasma optical emission spectrometry with axial and radial view configurations. Anal Chim Acta 445:269–275
Ikem A, Nwankwoala A, Odueyungbo S, Nyavor K, Egiebor N (2002) Levels of 26 elements in infant formula from USA, UK, and Nigeria by microwave digestion and ICP-OES. Food Chem 77:439–447
Inam R, Somer G (2000) Direct method for the determination of selenium and lead in cow's milk by differential pulse stripping voltammetry. Food Chem 69:345–350
Korn MGA, Boa Morte ES, Santos DCM, Castro JT, Barbosa JTP, Teixeira AP, Fernandes AP, Welz B, Santos WPC, Santos EBGN, Korn M (2008) Sample preparation for the determination of metals in food samples using spectroanalytical methods—a review. Appl Spectrosc Rev 43:67–92
Lara PCP, Silveira JN, Neto WB, Beinner MA, Da silva JBB (2014) Use of multivariate optimization to develop methods for direct copper and lead determination in breast milk by graphite furnace atomic absorption spectrometry. Food Anal Methods 7:790–797
McKinstry PJ, Indyk HE, Kim ND (1999) The determination of major and minor elements in milk and infant formula by slurry nebulization and inductively coupled plasma–optical emission spectrometry (ICP-OES). Food Chem 65:245–252
Mitra S (2003) Sample preparation techniques in analytical chemistry. Wiley, New Jersey
Momen AA, Zachariadis GA, Anthemidis AN, Stratis JA (2006) Investigation of four digestion procedures for multi-element determination of toxic and nutrient elements in legumes by inductively coupled plasma-optical emission spectrometry. Anal Chim Acta 565:81–88
Momen AA, Zachariadis GA, Anthemidis AN, Stratis JA (2007) Use of fractional factorial design for optimization of digestion procedures followed by multi-element determination of essential and non-essential elements in nuts using ICP-OES technique. Talanta 71:443–451
Nemati K, Bakar NKA, Abas MRB, Sobhanzadeh E, Low KH (2010) Comparative study on open system digestion and microwave assisted digestion methods for metal determination in shrimp sludge compost. J Hazard Mater 182:453–459
Oliveira E (2003) Sample preparation for atomic spectrometry: evolution and future trends. J Braz Chem Soc 14:174–182
Oreste EQ, Jesus A, Oliveira RM, Silva MM, Vieira MA, Ribeiro AS (2013a) New design of cold finger for sample preparation in open system: determination of Hg in biological samples by CV-AAS. Microchem J 109:5–9
Oreste EQ, Oliveira RM, Nunes AM, Vieira MA, Ribeiro AS (2013b) Sample preparation methods for determination of Cd, Pb and Sn in meat samples by GF AAS: use of acid digestion associated with a cold finger apparatus versus solubilization methods. Anal Methods 5:1590–1595
Pereira JSF, Pereira LSF, Schmidt L, Moreira CM, Barin JS, Flores EMM (2013) Metals determination in milk powder samples for adult and infant nutrition after focused-microwave induced combustion. Microchem J 109:29–35
Pinheiro ACA, Lisboa MT, Ribeiro AS, Nunes AM, Yamasaki A (2014) Avaliação da mineralização de arroz em sistema de refluxo para a determinação de Cu, Fe, Mn e Zn por F AAS. Quim Nov. 37:6–9
Ribeiro AS, Moretto AL, Arruda MAZ, Cadore S (2003) Analysis of powdered coffee and milk by ICP OES after sample treatment with tetramethylammonium hydroxide. Microchim Acta 141:149–155
Santos DM, Pedroso MM, Costa LM, Nogueira ARA, Nóbrega JA (2005) A new procedure for bovine milk digestion in a focused microwave oven: gradual sample addition to pre-heated acid. Talanta 65:505–510
Silva JCJ, Santos DM, Cadore S, Nobrega JA, Baccan N (2004) Evaluation of inductively coupled plasma optical emission spectrometers with axial configuration: interfaces with end-on gas and shear gas. Microchem J 77:185–190
Tokalioğlu Ş, Gürbüz F (2010) Selective determination of copper and iron in various food samples by the solid phase extraction. Food Chem 123:183–187
Trevizan LC, Nogueira AR, Nóbrega JA (2003) Single vessel procedure for acid vapor partial digestion of bovine liver in a focused microwave: multielement determination by ICP-OES. Talanta 61:81–86
Veloso ACA, Teixeira N, Ferreira IMPLVO, Ferreira MA (2002) Detecção de adulterações em produtos alimentares contendo leite e/ou proteínas lácteas. Quim Nov. 25:609–615
Wasilewska M, Goessler W, Zischka M, Maichin B, Knapp G (2002) Efficiency of oxidation in wet digestion procedures and influence from the residual organic carbon content on selected techniques for determination of trace elements. J Anal At Spectrom 17:1121–1125
Acknowledgments
The authors gratefully acknowledge the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), the Fundação de Amparo à Pesquisa do Estado de São Paulo, and CNPq/CAPES (Projeto Casadinho no. 552197/2011-4) for their financial support and scholarships.
Conflict of Interest
Eliézer Quadro Oreste has no conflict of interest. Alexander Ossanes de Souza has no conflict of interest. Camila Côrrea Pereira has no conflict of interest. Meibel Teixeira Lisboa has no conflict of interest. Mirla Janaína A. Cidade has no conflict of interest. Mariana Antunes Vieira has no conflict of interest. Solange Cadore has no conflict of interest. Anderson Schwingel Ribeiro has no conflict of interest.
Ethical Approval
This article does not contain any studies with human or animal subjects.
Informed Consent
Informed consent was obtained from all individual participants included in the study.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Oreste, E.Q., de Souza, A.O., Pereira, C.C. et al. Evaluation of Sample Preparation Methods for the Determination of Ca, Cu, Fe, K, and Na in Milk Powder Samples by ICP-OES. Food Anal. Methods 9, 777–784 (2016). https://doi.org/10.1007/s12161-015-0252-1
Received:
Accepted:
Published:
Issue Date: