Skip to main content
Log in

Validated RP-HPLC Method for Simultaneous Determination of Tocopherols and Tocotrienols in Whole Grain Barley Using Matrix Solid-Phase Dispersion

  • Published:
Food Analytical Methods Aims and scope Submit manuscript

Abstract

The vitamers of vitamin E such as α-, β-, γ-, and δ-tocotrienol and α-, β-, γ-, and δ- tocopherol are important phytochemical compounds with antioxidant activity and with potential benefits for human health. A high-performance liquid chromatography with fluorescence detection (HPLC-FLD) method was validated for their determination in whole grain barley samples. Tocol extraction was performed by an optimized matrix solid-phase dispersion (MSPD) protocol with neutral alumina (0.5 g) as the dispersion agent and methanol (5 mL) as the elution solvent. The analytical column was an Eclipse XDB C18 column (150 × 4.6 mm, 5 μm) and it was operated at room temperature. Mobile phase was consisted of methanol/acetonitrile/i-propanol (55:40:5 v/v %) and the elution was isocratic at a flow rate of 0.8 mL/min. Total analysis time was 12 min, and the detection of the tocols was performed with a fluorimetric detector where the excitation and emission wavelengths were set at 295 and 335 nm, respectively. Method validation was performed by means of intra-day (n = 5) and inter-day accuracy and precision (n = 8), sensitivity, and linearity. The linear regression coefficient (R 2) was higher than 0.99. The recoveries of the tocols from barley samples with the proposed extraction method were in an acceptable level (74–91 %) where the relative standard deviation ranged from 4.2 to 15.0 %. Limits of detection (LODs) and limits of quantification (LOQs) varied from 0.03 to 0.11 mg kg−1 and 0.11 to 0.34 mg kg−1, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

Download references

Conflict of Interest

Emmnouil D. Tsochatzis declares that he has no conflict of interest. Roxani Tzimou-Tsitouridou declares that she has no conflict of interest. This article does not contain any studies with human or animal subjects.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Emmanouil D. Tsochatzis.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tsochatzis, E.D., Tzimou-Tsitouridou, R. Validated RP-HPLC Method for Simultaneous Determination of Tocopherols and Tocotrienols in Whole Grain Barley Using Matrix Solid-Phase Dispersion. Food Anal. Methods 8, 392–400 (2015). https://doi.org/10.1007/s12161-014-9904-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12161-014-9904-9

Keywords

Navigation