Abstract
Sucrose coating of breakfast cereals is used to enhance the flavor and attractiveness of the final product but there is a need for monitoring its levels to meet consumer health concerns associated with sugar consumption. Our objective was to evaluate the use of portable (mid-infrared, MIR) and handheld (near-infrared, NIR) systems for rapid, simple and reliable determination of sucrose content in breakfast cereal products. Cereal-based and sucrose-coated samples were provided by an Ohio snack food company. Samples were ground and spectra were collected using portable ATR-MIR (Cary 630) and handheld NIR (microPHAZIR) spectrometers. Reference sucrose levels were determined by high-performance liquid chromatography (HPLC). Partial least squares regression (PLSR) was used to develop calibration regression models for prediction of sucrose levels in breakfast cereals based on spectral data. Sucrose levels in uncoated (n = 28) and coated (n = 62) cereal samples were on average of 1.2 ± 0.7 and 11.8 ± 3.5 g/100 g, respectively. Similar calibration (n = 85) model performances were obtained for determination of sucrose content by using the portable MIR and handheld NIR instruments with standard error of cross-validation (SECV) of 1.45 %. However, superior predictive ability was obtained with the portable MIR unit using a validation set (n = 20, SEP = 1.27 % and RPD = 4.41). Regression models using NIR spectrum of the cereal through a polyethylene bag resulted in reduction of the model goodness of fit and RPD values. Results support the application of handheld NIR and portable MIR spectrometers for close-to-real-time analysis of sucrose levels in breakfast cereals providing simple, rapid and reliable prediction for quality assurance.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-013-9763-9/MediaObjects/12161_2013_9763_Fig1_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-013-9763-9/MediaObjects/12161_2013_9763_Fig2_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-013-9763-9/MediaObjects/12161_2013_9763_Fig3_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-013-9763-9/MediaObjects/12161_2013_9763_Fig4_HTML.gif)
Similar content being viewed by others
References
Abdi H (2010) Partial least squares regression and projection on latent structure regression (PLS-regression). Wiley Interdiscip Rev Comput Stat 2:97–106
AOAC Official Method 982.14. 2007. Glucose, fructose, sucrose, and maltose in presweetened cereals—liquid chromatographic method. In “Official Methods of Analysis, 18th Ed. AOAC International. Gaithersburg. MD.
Bergmeyer HU, Bernt E (1974) Methods of Enzymatic Analysis, 2nd edn. Academic Press, New York, p 177
Burns D.A. , and E.W. Ciurczak, Handbook of Near-Infrared Analysis. 3rd ed. CRC Press. 826 (2007)
Cadet F, Bertrand D, Robert P, Maillot J, Dieudonne J, Rouch C (1991) Appl Spectrosc 45:166
Chavez-Servin JL, Castellote AI, Lopez-Sabater MC (2004) J Chromatogr A 1043:211
Chavis JC (2010) Global Cereal Market. Available from: http://www.brighthub.com/money/investing/articles/69179.aspx, Accessed April 13, 2013.
Choung MG (2010) J Korean Soc Appl Biol Chem 53:478
Coury C, Dillner AM (2008) Atmos Environ 42:5923
Farhat IA, Mousia Z, Mitchell JR (2003) Carbohyd Polym 52:29
Fernández-Artigas P, Guerra-Hernández E, Affiliation BG (2001) Food Chem 74:499
Fodor M, Woler A, Turza S, Szigedi T (2011) J Food Eng 107:195
Grube M, Bekers M, Upite D, Kaminska E (2002) Spectroscopy 16:289
Guillen MD, Cabo N (2000) J Sci Food Agric 80:2028
Kacurakova M, Mathlouthi M (1996) Carbohydr Res 284:145
Koplan JP, Brownell KD (2010) Jama 304:1487
Li BW, Schuhmann PJ (1980) J Food Sci 45:138
Liang CY, Marchessault RH (1959) J Polym Sci 39:269
Mazumder MK, Wankum DL, Sims RA, Mountain JR, Chen H, Pettit P (1997) J Electrostat 40:369
Murray I. and P.C. Williams, Chemical principles of near-infrared technology, in volume: Williams, P. and Norris, K. (eds.): Near-Infrared Technology in the Agricultural and Food Industries. American Association of Cereal Chemists, St. Paul, Minnesota, USA, p. 29–31. (1987).
Nichols PD, Henson JM, Guckert JB, Nivens DE, White DC (1985) J Microbiol Meth 4:79
Osborne B.G. , Near-infrared spectroscopy in food analysis. Encyclopedia of Analytical Chemistry. John Wiley & Sons: 1-14 (1993).
Osborne BG, Fearn T, Randall PG (1983) Int J Food Sci Technol 18:651
Putz AM, Putz MV (2012) Int J Mol Sci 13:15925
Saeys W, Mouazen AM, Ramon H (2005) Biosyst Eng 91:393
Santos PM, Pereira-Filho ER, Rodriguez-Saona LE (2013) J Agr Food Chem 61:1205
Solis-Morales D, Saenz-Hernandez CM, Ortega-Rivas E (2009) J Food Eng 93:236
Tewari JC, Malik K (2007) Int J Food Sci Technol 42:200
Torres-Martinez JL (2007) Particul Sci Technol 25:549
Wang T, Rodriguez-Saona LE (2012) J Food Sci 77:C874
Wilkerson ED, Sayajon GFG, Santos AM, Rodriguez-Saona LE, Anthon GE, Barrett DM (2013) J Agr Food Chem 61:2088
Wold S, Sijostrom M, Eriksson L (2001) Chemometr Intell Lab 58:109
Conflict of Interest
Chih-An Lin declares that she has no conflict of interest. Huseyin Ayvaz declares that he has no conflict of interest. Luis E. Rodriguez-Saona declares that he has no conflict of interest. This article does not contain any studies with human or animal subjects.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lin, CA., Ayvaz, H. & Rodriguez-Saona, L.E. Application of Portable and Handheld Infrared Spectrometers for Determination of Sucrose Levels in Infant Cereals. Food Anal. Methods 7, 1407–1414 (2014). https://doi.org/10.1007/s12161-013-9763-9
Received:
Accepted:
Published:
Issue Date: