Abstract
In this work, a method for on-line preconcentration and determination of zinc was developed. A miniglass column (35 × 3 mm) containing 70 mg of Dowex 1X8 resin modified with 1% (w/w) of zincon was coupled into the FI-FAAS system. During the extraction procedure, it was verified that the metal reacts with the complexing reagent in the pH range from 9.0 to 10.0. After optimization of parameters such as type and concentration of the eluent, buffer concentration, elution time, sample and buffer flow rate, mixing coil length, and effect of foreign ions, the FI-FAAS system presented an enrichment factor of 10 and at least 200 reutilizations of the column were possible. The detection limit was 0.67 μg L−1, and a relative standard deviation of 5% was obtained. The accuracy of the method was evaluated by using certified reference material, showing good accuracy. The proposed method was successfully applied for the determination of zinc in beverages.
Similar content being viewed by others
References
Ahmed YZ, Abdelmottalb M, Hassan AM (1985) Inorg Chim Acta 110:87–90
Anzano JM, Heinemann RJB, Mir JM (2004) At Spectrosc 25:221–225
Aydin FA, Soylak M (2007) Talanta 73:134–141
Cadore S, Goi RD, Baccan N (2005) J Braz Chem Soc 16:957–962
Chamjangali MA, Talebzadeh F, Bahramian B (2010) J Hazard Mater 174:843–850
Cozzolino SM (2007) Biodisponibilidade de nutrientes, 2nd edn. Manole, Barueri
Dadfarnia S, Shabani AMH, Tamaddon F, Rezaei M (2005) Anal Chim Acta 539:69–75
De Martino MG, Macarovscha GT, Cadore S (2010) Anal Methods 2:1258–1262
Gaber M, Mabrouk HE, Mounir M (1991) Thermochim Acta 186:89–95
Ghaedi M, Niknam K, Taheri K, Hossainiam H, Soylak M (2010) Food Chem Tox 48:891–897
Ghasemi J, Ahmadi S, Torkestani K (2007) Anal Chim Acta 487:181–188
Kara D (2009) Talanta 79:429–435
Karatepe A, Soylak M, Latif E (2011) Clean Soil Air Water 39:502–507
Leelasattarathkul T, Liawruangrath S, Rayanakorn M, Oungpipat W, Liawruangrath B (2006) Talanta 70:656–660
Leelasattarathkul T, Liawruangrath S, Rayanakorn M, Liawruangrath B, Oungpipat W, Youngvises N (2007) Talanta 72:126–131
Lemos VA, David GT, Santos LN (2006) J Braz Chem Soc 17:697–704
Li ZH, Chang XJ, Hu Z, Huang XP, Zou XJ, Wu Q, Nie R (2009) J Hazard Mater 166:133–137
Liu P, Pu Q, Su Z (2005a) J Anal Chem 60:1023–1029
Liu Y, Guo Y, Chang SM, Yang D, Din B (2005b) Microchim Acta 149:95–101
Liu Y, Guo Y, Meng S, Chang X (2007) Microchim Acta 158:239–245
Mabrouk HE, Gaber M, El-Sonbati AZ (1992) Trans Met Chem 17:1–4
Macarovscha GT, Bortoleto GG, Cadore S (2007) Talanta 71:1150–1154
Morgano MA, Queiroz SCN, Ferreira MMC (1999) Cienc Tecnol Alim 19:344–348
Pedrosa LFC, Cozzolino SMF (1993) Rev Saude Publica 27:266–270
Praveen RS, Daniel S, Rao TP (2005) Talanta 66:513–520
Preetha CR, Biju VM, Rao TP (2003) At Spectrosc 24:118–124
Rastegarzadeh S, Rezaei V (2008) Sensor Actuator B Chem 129:327–331
Ronsein GE, Dutra RL, Silva EL, Martinello F, Hermes EM, Balen G, Jorge S, Waltrick CDA, Silva CSM, Santos BM, Santos BM, Leal V, Roldão UQ, Cantos GA (2004) Acta Bioquim Clin Latinoam 38:39–46
Ruzicka J, Hansen EH (1975) Anal Chim Acta 78:145–157
Sabel CE, Neureuther JM, Siemann S (2010) Anal Biochem 397:218–226
Shpigun LK, Shushenachev YV, Kamilova PM (2006) Anal Chim Acta 573–574:360–365
Skoog DA (2006) Princípios de análise instrumental, 5th edn. Bookman, Porto Alegre
Soares LMV, Shishido K, Moraes AMM, Moreira VA (2004) Cienc Tecnol Alim 24:202–206
Soylak M, Aydin A (2011) Food Chem Tox 49:1242–1248
Soylak M, Dogan M (1996) Anal Lett 29:635–643
Taher MA, Mostafavi A, Mobarakeh SZ (2007) J Anal Chem 62:1022–1027
Urbano MRD, Vitalle MSS, Juliano Y, Amancio OMS (2002) J Pediatr 78:327–334
Yoe JH, Rush RM (1952) Anal Chim Acta 6:526–527
Acknowledgments
The authors gratefully acknowledge Dr. Carol H. Collins for assistance with English in this manuscript; and the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), the Fundação de Amparo à Pesquisa do Estado de São Paulo, and INCTAA (Instituto Nacional de Ciências e Tecnologias Analíticas Avançadas) for the financial support of this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Peixoto, R.R.A., Macarovscha, G.T. & Cadore, S. On-line Preconcentration and Determination of Zinc Using Zincon and Flame Atomic Absorption Spectrometry. Food Anal. Methods 5, 814–820 (2012). https://doi.org/10.1007/s12161-011-9316-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12161-011-9316-z