The aim of the study was to compare the diagnostic performances of visual and quantitative analyses of double-phase Tc-99m methoxyisobutylisonitrile (MIBI) scintimammography (SMM) in patients with ultrasonographically indeterminate findings. SMM (early: 10 min; delayed: 3 h) was performed on 78 patients (malignant 66, benign 12). For visual analysis, the five-scoring method was used. For quantitative analysis, ratios of early and delayed lesions to non-lesion (L/Ns) were calculated. When a visual grade of over 3 was used as the cut-off value for the detection of primary breast cancer, the sensitivity and specificity were 86.4% and 100%, respectively. The area under the curve (AUC) was 0.972. The optimal L/N ratios were 1.22 for early and 1.1 for delayed images. When early L/N 1.22 was used as the cut-off point, the sensitivity and specificity of SMM were 92.4% and 91.7%, respectively. The AUC was 0.952. When delayed L/N 1.1 was used as the cut-off value, the sensitivity and specificity were 78.8% and 91.7%, respectively. The AUC was 0.863. Visual interpretation and early L/N were superior to delayed L/N for the detection of breast cancer. This study suggests the possible diagnostic role of visual and quantitative analyses of double-phase SMM for differentiating malignant breast lesions in patients with ultrasonographically indeterminate findings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Parkin DM, Whelan SL, Ferlay J, Teppo L, Thomas DB. Cancer in cidence in five continents, vol 8. IARC Scientific Publication No. 155, Lyon; 2002

  2. L Nystrom I Andersson N Bjurstam J Frisell B Nordenskjold LE Rutqvist (2002) ArticleTitleLong-term effects of mammography screening: updated overview of the Swedish randomized trails Lancet 359 909–19 Occurrence Handle11918907 Occurrence Handle10.1016/S0140-6736(02)08020-0

    Article  PubMed  Google Scholar 

  3. SG Orel N Kay C Reynolds DC Sullivan (1999) ArticleTitleBI-RADS categorization as a predictor of malignancy Radiology 211 845–50 Occurrence Handle10352614 Occurrence Handle1:STN:280:DyaK1M3otVyrsg%3D%3D

    PubMed  CAS  Google Scholar 

  4. MS Alam K Kasagi T Misaki S Miyamoto M Iwata Y Iida et al. (1998) ArticleTitleDiagnostic value of technetium-99m methoxyisobutylisonitrile scintigraphy in detecting thyroid cancer metastases: a critical evaluation Thyroid 8 1091–100 Occurrence Handle9920363 Occurrence Handle1:STN:280:DyaK1M7hslSqsw%3D%3D

    PubMed  CAS  Google Scholar 

  5. HS Bom YC Kim HC Song JJ Min JY Kim KO Park (1998) ArticleTitleTechnetium-99m-MIBI uptake in small cell lung cancer J Nucl Med 39 91–4 Occurrence Handle9443743 Occurrence Handle1:STN:280:DyaK1c7gtl2rsg%3D%3D

    PubMed  CAS  Google Scholar 

  6. SJ Kim IJ Kim YK Kim (2002) ArticleTitleTc-99m MIBI, Tc-99m tetrofosmin, and Tc-99m (V) DMSA accumulation in recurrent malignant thymoma Clin Nucl Med 27 30–3 Occurrence Handle11805481 Occurrence Handle10.1097/00003072-200201000-00007

    Article  PubMed  Google Scholar 

  7. SJ Kim IJ Kim YT Bae YK Kim (2000) ArticleTitleTechnetium-99m tetrofosmin scintimammography in suspected breast cancer patients: a comparison with technetium-99m MIBI Med Princ Pract 9 282–9 Occurrence Handle10.1159/000054255

    Article  Google Scholar 

  8. SJ Kim JW Seok IJ Kim YK Kim (2002) ArticleTitleTc-99m MIBI scintigraphy in a patient with primary and metastatic malignant melanoma Clin Nucl Med 27 351–3 Occurrence Handle10.1097/00003072-200205000-00008

    Article  Google Scholar 

  9. D Moka E Voth M Dietlein A Larena Avellaneda H Schicha (2000) ArticleTitleTechnetium 99m-MIBI-SPECT: A highly sensitive diagnostic tool for localization of parathyroid adenomas Surgery 128 29–35 Occurrence Handle10876182 Occurrence Handle10.1067/msy.2000.107066 Occurrence Handle1:STN:280:DC%2BD3czjs1yltg%3D%3D

    Article  PubMed  CAS  Google Scholar 

  10. O Alonso T Massardo LB Delgado J Horvath L Kabasakal A Llamas-Olier et al. (2001) ArticleTitleIs 99mTc-sestamibi scintimammography complementary to conventional mammography for detecting breast cancer in patients with palpable masses? J Nucl Med 42 1614–21 Occurrence Handle11696629 Occurrence Handle1:STN:280:DC%2BD3MnksValtw%3D%3D

    PubMed  CAS  Google Scholar 

  11. E Ambrus K Ormandi T Sera A Toszeqi L Csernay L Pavics (1998) ArticleTitleThe role of 99mTc-MIBI mammoscintigraphy in the diagnosis of breast cancer Orv Hetil 139 183–7 Occurrence Handle9478054 Occurrence Handle1:STN:280:DyaK1c7jvVGnsw%3D%3D

    PubMed  CAS  Google Scholar 

  12. SJ Kim IJ Kim YT Bae YK Kim DS Kim (2005) ArticleTitleComparison of quantitative and visual analysis of Tc-99m MIBI scintimammography for detection of primary breast cancer Eur J Radiol 53 192–8 Occurrence Handle15664282 Occurrence Handle10.1016/j.ejrad.2003.10.024

    Article  PubMed  Google Scholar 

  13. F Scopinaro S Mezi M Ierardi G De Vincentis NS Tiberio V David et al. (1998) ArticleTitle 99mTc-MIBI prone scintimammography in patients with suspicious breast cancer: relationship with mammography and tumor size Int J Oncol 12 661–4 Occurrence Handle9472108 Occurrence Handle1:STN:280:DyaK1c7jvFKitA%3D%3D

    PubMed  CAS  Google Scholar 

  14. SM Durfee DLG Selland DN Smith SC Lester CM Kaelin JE Meyer (2000) ArticleTitleSonographic evaluation of clinically palpable breast cancers invisible on mammography Breast J 6 247–51 Occurrence Handle11348373 Occurrence Handle10.1046/j.1524-4741.2000.99111.x

    Article  PubMed  Google Scholar 

  15. TJ Hieken JM Velasco (1998) ArticleTitleA prospective analysis of office-based breast ultrasound Arch Surg 133 504–8 Occurrence Handle9605912 Occurrence Handle10.1001/archsurg.133.5.504 Occurrence Handle1:STN:280:DyaK1c3ms12nuw%3D%3D

    Article  PubMed  CAS  Google Scholar 

  16. ED Staren (1998) ArticleTitleBreast ultrasound Surg Clin North Am 78 219–35 Occurrence Handle9602844 Occurrence Handle10.1016/S0039-6109(05)70310-8 Occurrence Handle1:STN:280:DyaK1c3msFGmtg%3D%3D

    Article  PubMed  CAS  Google Scholar 

  17. WA Berg CI Campassi OB Ioffe (2003) ArticleTitleCystic lesions of the breast: sonographic-pathologic correlation Radiology 227 183–91 Occurrence Handle12668745 Occurrence Handle10.1148/radiol.2272020660

    Article  PubMed  Google Scholar 

  18. SJ Kim IJ Kim YT Bae YK Kim DS Kim (2004) ArticleTitleIncremental diagnostic value of quantitative analysis of double phase Tc-99m MIBI scintimammography for the detection of primary breast cancer additive to visual analysis Breast Cancer Res Treat 83 129–38 Occurrence Handle14997043 Occurrence Handle10.1023/B:BREA.0000010705.31599.89

    Article  PubMed  Google Scholar 

  19. RE Bird TW Wallace BC Yankaskas (1992) ArticleTitleAnalysis of cancers missed at screening mammography Radiology 184 613–7 Occurrence Handle1509041 Occurrence Handle1:STN:280:DyaK38zns1WksQ%3D%3D

    PubMed  CAS  Google Scholar 

  20. DB Kopans (1992) ArticleTitlePositive predictive value of mammography Am J Roentgenol 158 521–6 Occurrence Handle1:STN:280:DyaK387lt1WisA%3D%3D

    CAS  Google Scholar 

  21. ED Staren R Fine (1996) ArticleTitleBreast ultrasound for surgeons Am Surg 62 108–12 Occurrence Handle8554186 Occurrence Handle1:STN:280:DyaK287ks1Glsg%3D%3D

    PubMed  CAS  Google Scholar 

  22. L Louie N Velez D Earnest ED Staren (2003) ArticleTitleManagement of nonpalpable ultrasound-indeterminate breast lesions Surgery 134 667–74 Occurrence Handle14605628 Occurrence Handle10.1016/S0039-6060(03)00318-0

    Article  PubMed  Google Scholar 

  23. N Arslan E Ozturk S Ilgan Y Narin S Dundar T Tufan et al. (2000) ArticleTitleThe comparison of dual phase Tc-99m MIBI and Tc-99m MDP scintimammography in the evaluation of breast masses: preliminary report Ann Nucl Med 14 39–46 Occurrence Handle10770579 Occurrence Handle1:STN:280:DC%2BD3c3jtFenug%3D%3D

    PubMed  CAS  Google Scholar 

  24. G Lu WJ Shih HY Huang MQ Long Q Sun YH Liu et al. (1995) ArticleTitleTc-99m MIBI mammoscintigraphy of breast masses: early and delayed imaging Nucl Med Commun 16 150–6 Occurrence Handle7770238 Occurrence Handle1:STN:280:DyaK2M3ovVSmtA%3D%3D Occurrence Handle10.1097/00006231-199516030-00007

    Article  PubMed  CAS  Google Scholar 

  25. M Melloul A Paz G Ohana O Laver D Michalevich R Koren et al. (1999) ArticleTitleDouble-phase 99mTc-sestamibi scintimammography and trans-scan in diagnosing breast cancer J Nucl Med 40 376–80 Occurrence Handle10086698 Occurrence Handle1:STN:280:DyaK1M7osVGjsA%3D%3D

    PubMed  CAS  Google Scholar 

  26. A Paz M Melloul S Cytron R Koren G Ohana D Michalevich et al. (2000) ArticleTitleThe value of early and double phase 99mTc-sestamibi scintimammography in the diagnosis of breast cancer Nucl Med Commun 21 341–8 Occurrence Handle10845222 Occurrence Handle10.1097/00006231-200004000-00008 Occurrence Handle1:STN:280:DC%2BD3cvosVSgtQ%3D%3D

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seong-Jang Kim.

Additional information

This work was supported by Pusan National University Research Grant

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, SJ., Bae, YT., Lee, J. et al. Diagnostic performances of double-phase Tc-99m MIBI scintimammography in patients with indeterminate ultrasound findings: visual and quantitative analyses. Ann Nucl Med 21, 145–150 (2007). https://doi.org/10.1007/s12149-006-0002-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12149-006-0002-y

Key words

Navigation