Identification of Nasal Irrigation Bottle Contamination in Post Sinonasal Surgery

  • Original Article
  • Published:
Indian Journal of Otolaryngology and Head & Neck Surgery Aims and scope Submit manuscript

Abstract

Nasal irrigation is an effective and cheap method in managing post sinonasal surgery patients. It works by improving ciliary clearance and performing mechanical debridement of the thick crust, decreasing mucosal edema and reducing the inflammatory mediators. Presence of nasal irrigation bottle contamination and its effect on patients have been studied. The aim of this study is to prospectively identify the risk of contamination in the nasal irrigation bottle, fluid from the bottle and to correlate with endoscopic findings from the patients who had underwent sinonasal surgery. Swabs will be taken from the nasal irrigation bottle and patient’s middle meatus before the surgery and at each post surgery visits (2 and 4 weeks). Patients will be advised to irrigate their nose three times per day post sinonasal surgery. During endoscopic examination of the patient’s nasal cavity at 2 and 4 weeks, any evidence of infection will be noted and documented. Additionally, a swab of fluid irrigated from the nasal cavity collected during the clinic follow-ups will also be taken. The specimens will be sent to the Microbiology laboratory for standard culture and sensitivity test. A total of 27 patients completed the study and were divided into case (n = 15) and control (n = 12) groups. The CFU (colony-forming unit) value of the bacteria cultured from the nasal cavity and the nasal irrigation bottle was statistically significantly (P = 0.00) increased from the baseline to the second week follow-up in both groups but not from the second week to the fourth week follow-up. The majority of the swabs from the nasal cavity of the patients and the nasal irrigation bottles were positively cultured for Pseudomonas sp. group. Other groups of bacteria that were cultured were Enterobacter sp., Coagulase Negative Staphylococcus (CONS) and Klebsiella sp. Endoscopically, there was no clinical evidence of infection found in the nasal cavity of the patients. The nasal irrigation bottle that was used in the post sinonasal surgery treatment and for alleviation of symptoms of sinonasal diseases was found to have bacterial contamination from the swabs taken from the bottle. However, despite this finding there was not clinical evidence of infection noted from the nasal endoscopic examination. A simple and effective method of cleaning the bottle would be helpful to reduce the bacterial contamination for this useful treatment method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Hernandez JG (2007) Nasal saline irrigation for sinonasal disorders. Phillipine J Otolaryngol Head Neck Surg 22(1):37–39

    Article  Google Scholar 

  2. Heatley DG, McConnell KE, Kille TL, Leverson GE (2001) Nasal irrigation for alleviation of sinonasal symptoms. Otolarygol Head Neck Surg 125:44–48

    Article  CAS  Google Scholar 

  3. Papsin B, McTavish A (2003) Saline nasal irrigation: its role as an adjunct treatment. Can Fam Physician 49:168–173

    PubMed  PubMed Central  Google Scholar 

  4. Keen M, Foreman A, Wormald P-J (2010) The clinical significance of nasal irrigation bottle contamination. Laryngoscope 120:2110–2121

    Article  Google Scholar 

  5. Isenberg HD (2004) Nasal sinus culture in clinical microbiology procedure handbook, 2nd edn. ASM Press, Washington

    Google Scholar 

  6. Welch KC, Cohen MB, Doghramji LL, Cohen NA, Chandra RK, Palmer JN, Chiu AG (2009) Clinical correlation between irrigation bottle contamination and clinical outcomes in post-functional endoscopic sinus surgery patients. Am J Rhinol Allergy 23:401–404

    Article  Google Scholar 

  7. Rabago D, Zgierska A (2009) Saline nasal irrigation for upper respiratory conditions. Am Fam Physician 80(10):117–119

    Google Scholar 

  8. Rudmik L, Soler ZM, Orlandi RR, Stewart MG, Bhattacharyya N, Kennedy DW, Smith TL (2011) Early postoperative care following endoscopic sinus surgery: an evidence-based review with recommendations. Int Forum Allergy Rhinol 1(6):417–430

    Article  Google Scholar 

  9. Lee JM, Nayak JV, Doghramji LL, Welch KC, Chiu AG (2010) Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery. Am J Rhinol Allergy 24:197–199

    Article  Google Scholar 

  10. Lewenza S, Charron-Mazenod L, Cho JW, Mechor B (2010) Identification of bacterial contaminants in sinus irrigation bottles from chronic rhinosinusitis patients. J Otolaryngol Head Neck Surg 39(4):458–463

    PubMed  Google Scholar 

  11. Foreman A, Wormald P-J (2011) Can bottle design prevent bacterial contamination of nasal irrigation devices? Int Forum Allergy Rhinol 1(4):303–307

    Article  Google Scholar 

Download references

Acknowledgements

This study was funded by Secretariat for Medical Research and Innovation, UKM Medical Center.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Farah Dayana Zahedi.

Ethics declarations

Conflict of interest

All the authors stated above declare that they have no conflict of interest.

Ethical Approval

All procedures performed in this study were in accordance with the ethical standards of Reseach Ethic Committee Universiti Kebangsaan Malaysia (RECUKM) and with the the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Formal consent obtained from each of the individuals in this study.

Informed Consent

Informed consent together with formal consent were obtained from all individual participants for whom indentifying information is included in this article.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zahedi, F.D., Asmi, N.H., Husain, S. et al. Identification of Nasal Irrigation Bottle Contamination in Post Sinonasal Surgery. Indian J Otolaryngol Head Neck Surg 71 (Suppl 3), 1837–1842 (2019). https://doi.org/10.1007/s12070-017-1219-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12070-017-1219-x

Keywords

Navigation