Entrapment of a Swan-Ganz catheter to an intracardiac structure in open heart operation is a rare but serious complication. In the intracardiac course, the catheter tends to rest against the anterior-lateral wall of the right atrium where the catheter can be caught by a suture during cannulation for cardiopulmonary bypass1. A Swan-Ganz catheter entrapment by a suture in the inferior vena caval (IVC) cannulation site during mitral valve replacement is presented. The diagnosis of the suture entrapment of the Swan-Ganz catheter was established by fluoroscopic observation of the specific movement pattern of the cardiac structures when manual traction was applied from outside. In conclusion, awareness of potential catheter entrapment by suture or other mechanisms should be the first step for management, when resistance is met during catheter withdrawal. Smooth partial withdrawal of the catheter prior to initiation of cardiopulmonary bypass(CPB), or at least before chest closure, to detect catheter mobility would provide an early clue for the diagnosis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wang HJ, Wang SS, Liau CS. Transesophageal Echocardiographic Diagnosis of Intracardiac Entrapment of a Swan-Ganz Catheter in Open Heart Operation: J Am Soc Echocardiogr 2004; 17: 277–279.

    Article  PubMed  Google Scholar 

  2. Huang L, Elsharydah A, Nawabi A, Cork RC. Entrapment of Pulmonary Artery Catheter in a Suture at the Inferior Vena Cava Cannulation Site: J Clin Anesth 2004; 16: 557–559.

    Article  PubMed  Google Scholar 

  3. Kaplan M, Demirtas M, Cimen S. et al Swan-Ganz catheter entrapment in open heart surgery: J Card Surg 2000; 15: 313–315.

    Article  PubMed  CAS  Google Scholar 

  4. Petrilli G, Peranzoni PF, Barbieri E. A non surgical technique for removal of a Swan-Ganz Catheter entrapment in the right atrium. J Cardiovasc Surg 1992; 33: 251–252.

    CAS  Google Scholar 

  5. Huang GS, Wang HJ, Chen CH, Ho ST, Wong CS. Pulmonary artery rupture after attempted removal of a pulmonary artery catheter. Anesth Analg 2002; 95: 299–301.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ranjith Baskar Karthekeyan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karthekeyan, R.B., Rao, S., Vakamudi, M. et al. Accidental entrapment of swan ganz in inferior vena caval cannulation site-A case report. Indian J Thorac Cardiovasc Surg 23, 283–285 (2007). https://doi.org/10.1007/s12055-007-0062-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12055-007-0062-1

Key words

Navigation