Abstract
The present study presents the bin weather data for four cities in the tropical region and its significance in the building energy analysis. The bin weather data for four cities in Malaysia, which are Bayan Lepas, Kuala Terengganu, Senai and Kuching, were generated. The bin weather data are in the range from 18 to 38 °C with 2 °C intervals and tabulated based on six 4-h shifts. Since there is a lack of updated bin weather data in Malaysia, the present paper provides valuable data for engineers and designers to conduct an energy analysis using the bin method in this region. This data may also serve as an important reference for all tropical regions with similar weather characteristics. Energy analysis is an important tool for estimating the energy usage of a building in order to minimize energy wastage and maximize energy efficiency. The significance of applying bin weather data in energy analysis is also investigated using a case simulation. When the mean outdoor temperature of occupied period is used in simulation, the results deviate less than 1.6% from the results with the bin weather data, but the deviation rises up to 16.68% with the use of the annual mean outdoor dry bulb temperature.
Similar content being viewed by others
Abbreviations
- BLAST:
-
Building Loads Analysis and System Thermodynamics
- GWP:
-
Global warming potential
- HEED:
-
Home Energy Efficient Design
- HVAC:
-
Heating, ventilating, and air-conditioning
- IES-VE:
-
Integrated Environmental Solutions – Virtual Environment
- ODP:
-
Ozone depletion potential
- TRNSYS:
-
Transient Systems Simulation Program
References
Al-Homoud, M. S. (2001). Computer-aided building energy analysis techniques. Building and Environment, 36, 421–433.
Auffhammer, M., & Aroonruengsawat, A. (2011). Simulating the impacts of climate change, prices and population on California’s residential electricity consumption. Climatic Change, 109, 191–210.
Brown, M. A., Cox, M., Staver, B., & Baer, P. (2016). Modeling climate-driven changes in US buildings energy demand. Climatic Change, 134, 29–44.
Bulut, H., Büyükalaca, O., & Yılmaz, T. (2001). Bin weather data for Turkey. Applied Energy, 70, 135–155.
Chau, C., Leung, T., & Ng, W. (2015). A review on life cycle assessment, life cycle energy assessment and life cycle carbon emissions assessment on buildings. Applied Energy, 143, 395–413.
Coakley, D., Raftery, P., & Keane, M. (2014). A review of methods to match building energy simulation models to measured data. Renewable and Sustainable Energy Reviews, 37, 123–141.
Day, A., Knight, I., Dunn, G., & Gaddas, R. (2003). Improved methods for evaluating base temperature for use in building energy performance lines. Building Services Engineering Research and Technology, 24, 221–228.
Ebrahimpour, A., & Maerefat, M. (2010). A method for generation of typical meteorological year. Energy Conversion and Management, 51, 410–417.
Fazeli, R., Ruth, M., & Davidsdottir, B. (2016). Temperature response functions for residential energy demand—a review of models. Urban Climate, 15, 45–59.
Idchabani, R. 2018. Bin weather data for five climatic zones of Morocco. International Journal of Ambient Energy, 1-8.
Jin, Z., Yezheng, W., & Gang, Y. (2006). A stochastic method to generate bin weather data in Nanjing, China. Energy Conversion and Management, 47, 1843–1850.
Kreider, J. F., Curtiss, P. S. & Rabl, A. 2009. Heating and cooling of buildings: design for efficiency. CRC Press.
Krese, G., Prek, M., & Butala, V. (2012). Analysis of building electric energy consumption data using an improved cooling degree day method. Strojniški vestnik-Journal of Mechanical Engineering, 58, 107–114.
Manfren, M., Aste, N., & Moshksar, R. (2013). Calibration and uncertainty analysis for computer models—a meta-model based approach for integrated building energy simulation. Applied Energy, 103, 627–641.
Mcquiston, F. C. & Parker, J. D. 2005. Heating, ventilating, and air conditioning: analysis and design.
Meng, Q., & Mourshed, M. (2017). Degree-day based non-domestic building energy analytics and modelling should use building and type specific base temperatures. Energy and Buildings, 155, 260–268.
METMALAYSIA 2017. Annual Report 2017. In: RAHMAN, R. A. (ed.). Malaysia: Malaysian Meteorological Department.
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014). A review on simulation-based optimization methods applied to building performance analysis. Applied Energy, 113, 1043–1058.
Noriah, A., & Rakhecha, P. (2001). Probable maximum precipitation for 24 h duration over southeast Asian monsoon region—Selangor, Malaysia. Atmospheric Research, 58, 41–54.
Özyurt, Ö., Bakirci, K., Erdoğan, S., & Yilmaz, M. (2009). Bin weather data for the provinces of the Eastern Anatolia in Turkey. Renewable Energy, 34, 1319–1332.
Papakostas, K. (1999). Technical note bin weather data of Athens, Greece. Renewable Energy, 17, 265–275.
Papakostas, K., Bentoulis, A., Bakas, V., & Kyriakis, N. (2007). Estimation of ambient temperature bin data from monthly average temperatures and solar clearness index. Validation of the methodology in two Greek cities. Renewable Energy, 32, 991–1005.
Papakostas, K., Tsilingiridis, G., & Kyriakis, N. (2008). Bin weather data for 38 Greek cities. Applied Energy, 85, 1015–1025.
Peng, Z., Jin, Z., Guoqiang, Z., & Yezheng, W. (2009). Generation of ambient temperature bin data of 26 cities in China. Energy Conversion and Management, 50, 543–553.
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008). A review on buildings energy consumption information. Energy and Buildings, 40, 394–398.
Pusat, S. (2019). A simple approach to estimate ambient temperature bin data. Energy Efficiency, 12, 1053–1064.
Pusat, S., & Ekmekci, I. (2016). A study on degree-day regions of Turkey. Energy Efficiency, 9, 525–532.
Pusat, S., Ekmekçi, İ., & Akkoyunlu, M. T. (2015). Generation of typical meteorological year for different climates of Turkey. Renewable Energy, 75, 144–151.
Saidur, R. (2009). Energy consumption, energy savings, and emission analysis in Malaysian office buildings. Energy Policy, 37, 4104–4113.
Sarak, H., & Satman, A. (2003). The degree-day method to estimate the residential heating natural gas consumption in Turkey: a case study. Energy, 28, 929–939.
Schicktanz, M. D., Döll, J., & Fugmann, H. (2014). Calculation of solar gains for solar heating and cooling using the bin-method. Energy Procedia, 48, 1665–1675.
Suhaila, J., Deni, S. M., Zin, W. Z. W., & Jemain, A. A. (2010). Trends in Peninsular Malaysia rainfall data during the southwest monsoon and northeast monsoons seasons: 1975-2004. Sains Malaysiana, 39, 533–542.
Tangang, F., Juneng, L., & Ahmad, S. (2007). Trend and interannual variability of temperature in Malaysia: 1961–2002. Theoretical and Applied Climatology, 89, 127–141.
Wang, Z., Ding, Y., Geng, G., & Zhu, N. (2014). Analysis of energy efficiency retrofit schemes for heating, ventilating and air-conditioning systems in existing office buildings based on the modified bin method. Energy Conversion and Management, 77, 233–242.
Yau, Y., & Hasbi, S. (2013). A review of climate change impacts on commercial buildings and their technical services in the tropics. Renewable and Sustainable Energy Reviews, 18, 430–441.
Zhao, H.-X., & Magoulès, F. (2012). A review on the prediction of building energy consumption. Renewable and Sustainable Energy Reviews, 16, 3586–3592.
Acknowledgements
The authors thank the Malaysian Meteorological Department for providing valuable weather data for the present research.
Funding
The authors would like to thank the Daikin Fellowship Grant for funding the project PV018-2016. In addition, special thanks are extended to University of Malaya for providing partial RU Grants GPF004A-2018 and IIRG014A-2019 to the authors for research work to be conducted at University of Malaya.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that there is no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Yau, Y.H., Wong, C.M., Ong, H.C. et al. Application of the bin weather data for building energy analysis in the tropics. Energy Efficiency 13, 935–953 (2020). https://doi.org/10.1007/s12053-020-09862-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12053-020-09862-8