Introduction

Issues related to use of lifting devices are not widely discussed within world’s literature. Main scientific trends deliberated by authors concern broadly understood mathematical analysis connected with vibrations of rope systems, acoustic emission generated during the operation (Lonkwic and Szydło 2016), and in research papers (Syta and Lonkwic 2016; Longwic and Szydło 2017; Szydło et al. 2016), authors describe results of their own investigations of braking systems of the lifts. Elevators are basic equipment of the building and increasing their energy efficiency is crucial in terms of the whole building efficiency (Goldstein and Eley 2014; Zhou et al. 2012). Energy that they use depends on the device type, location of installation and usage intensity connected to passenger traffic. Construction factors (device type, drive and control type, roping ratio and overbalancing of the system, etc.) and operation parameters (e.g. rated speed, acceleration and deceleration, travel distance, direction of travel, nominal load, number of trips) are what influences the energy efficiency. Impact of some of these factors on energy consumption has been described by authors (Anand and Mahesh 2017; Papanikolaou et al. 2017; Tukia et al. 2016a, b; Siikonen et al. 2010; Nipkow and Schalcher 2005). Use of new technical solutions can significantly contribute in decreasing the energy used by lifts and improve their energy efficiency. One of the basic elements impacting the improvement of energy efficiency of the lift is drive and control type. In publications (Anand and Mahesh 2016; Goergiev and Mirchevski 2012; Karlis 2014), authors point out the benefits of using the newest solutions. Issues related to energy efficiency of lifting devices were also raised by authors (Al-Sharif 2004; Almeida et al. 2012; Barney 2013; Doolaard 1992; Lorente et al. 2010; Nipkow and Schalcher 2005; Schroeder 1980, 1988, Tukia et al. 2016a, b).

Evaluations of the energy performance by commonly applied methods (VDI 4707-1 2009; ISO 25745-2 2015; E4 Project 2010) may prove inadequate and in some cases, assessment of electricity consumption may not be fully reliable. It is mostly due to certain simplifying assumptions underlying the computation and measurement procedures (for example, too general classifications of lift installations in terms of their functional features, leaving much room for interpretations, adopting hypothetical models of duty cycle of the machine identical for all types of buildings and installations, or a simplified procedure of energy consumption measurements taken during the test ride only and for a short period of time in the standby mode), affecting the final classification results. In order to accurately establish the energy performance of a machine or installation, it is required that several factors impacting on the actual power consumption are taken into account. Operating and energy performance parameters determined under the service conditions are of particular importance. Accordingly, a new method was worked out to determine the energy efficiency ratings of lift installations based on measurements taken with the purpose-built system to support energy performance measurements and energy parameter acquisition.

Estimator of the energy efficient classification—main objectives

Underlying the energy efficiency classification system are the following assumptions summarised in (Krakowski et al. 2015):

  • Recording of operating and energy performance parameters of a lift installation enables reliable assessment of its energy efficiency ratings;

  • It is required that energy performance parameters of the lift installation (active power ratings of the drive unit, of the lift car unit and of the entire lift) as well as operating parameters (distance travelled, transported mass, travel time, the number of trips) are registered over a weekly duty cycle in the form of time dependencies;

  • Important from drive and energy usage point of view construction factors (e.g. roping type and overbalancing of the system) and operation parameters (e.g. acceleration, deceleration and direction of travel) are included in the results of actual energy consumption measurement;

  • The week-long recording time allows duty cycle of the lift to be accurately modelled, the model being specific to the given lift installation operated in the building;

  • Time dependencies determined over a weekly duty cycle (e.g. excluding holidays or idle time) of operating and energy performance parameters are determined recalling the usage patterns and can be taken as repeatable in other weeks with the allowed uncertainty limits. Recurring passenger traffic conditions for lifts and escalators have been described by (Tukia et al. 2016a, b; Uimonen et al. 2017);

  • The energy efficiency rating of a lift installation is not constant, it varies with the changes in energy uptake during the ride, in the standby mode and in relation to operating parameters, such as for example the transported mass or the distance covered, travel direction, speed, acceleration and deceleration;

  • A parameter is introduced expressing the usage factor or operational equipment effectiveness for the lift;

  • To determine the energy efficiency rating of a lift installation, it is required that the running and standby energy efficiency and operational equipment effectiveness factor variations are plotted in the function of time;

  • Thus, obtained time dependencies of the energy efficiency ratings yield the average energy efficiency which can be treated as the final value in the classification procedure.

These assumptions have underpinned the developed heuristic estimator of the energy efficiency ratings of lift installations. It relies on the fuzzy logic approach, enabling us to solve problems involved in nonlinear relationships between variables characterising the object, an incomplete model of the object and interactions due to non-measurable disturbances. This approach facilitates the data analysis, particularly in the case of multi-dimensional objects.

The lift energy efficiency classification requires common criteria for assessing a diversity of objects, whilst the actual energy efficiency ratings involve several factors, rendering the fuzzy logic approach a viable solution. The fuzzy logic estimator was developed using the Matlab-Simulink packages complete with the Fuzzy Logic toolbox. Thus, developed fuzzy model is constructed using the Mamdani-type linguistic approach.

Estimator of lift energy efficiency

The energy efficiency classification and certification procedure use the time dependencies of operating and energy performance parameters of the analysed lift. A purpose-built data acquisition system is used which registers lift parameters (Krakowski et al. 2013, 2015). The outlined lift efficiency classification procedure relies on distributions of parameters listed in Table 1 determined on an hourly basis. In the light of the underlying assumptions, the distribution patterns should cover a 7-day duty cycle. The calculation procedure uses also lift parameters collated in Table 2.

Table 1 Operating and energy performance parameters required for lift energy efficiency classification
Table 2 Technical data required for lift energy efficiency classification

The maximal possible number of trips within 1-h running under the maximal lift loading (lJG) can be determined by measurements or derived from Formula (1):

$$ {l}_{JG}=\frac{3600}{t_{J\operatorname{MAX}}} $$
(1)

where tJmax indicates the maximal length of the duty cycle from instant the maximal admissible number of passengers enters the lift car to door closing, travel between two final levels, door opening, right through to the moment the maximal admissible number of passengers leaves the car.

The estimator structure is shown schematically in Fig. 1. Measured hourly distributions of performance parameters are summarised in Table 1 and the data compiled in Table 2 enter the data processing block yielding the values of input parameters for further calculations in the fuzzy logic estimator block:

  • running energy factor FJ, derived from the formula:

Fig. 1
figure 1

Fuzzy logic estimator for lift energy efficiency classification (symbol designations given in Tables 1 and 2)

$$ {F}_J=\left\{\begin{array}{c}0\kern6em if\kern0.50em {l}_J=0\\ {}\frac{E_J}{S\bullet \left(\frac{m}{l_J}\right)}\bullet 1000\kern1em if\kern0.50em {l}_J>0\end{array}\right. $$
(2)
  • average active power in the standby mode PC, derived from the formula:

$$ {P}_C=\left\{\begin{array}{c}0\kern3.75em if\ {t}_J=1\\ {}\frac{E_C}{1-{t}_J}\kern2em if\ {t}_J<1\end{array}\right. $$
(3)
  • energy consumption factor of the drive iE, expressed as the ratio of energy consumption by the driving unit EN to total energy consumption by the entire installation per 1 h E, derived from the formula:

$$ {i}_E=\frac{E_N}{E} $$
(4)
  • travel distance factor iH, expressing the ratio of running distance S travelled by the lift per 1 h to the maximal possible distance travelled by the lift in 1 h under the maximal loading (H.lJG):

$$ {i}_H=\frac{S}{H\bullet {l}_{JG}} $$
(5)
  • loading factor iQ indicates the ratio of mass carried by the lift m in 1 h to the maximal possible mass carried by the lift in 1 h (Q.lJG), derived from the formula:

$$ {i}_Q=\frac{m}{Q\bullet {l}_{JG}} $$
(6)

The fuzzy estimator block is shown schematically in Fig. 2. It incorporates four sections which determine:

  • running lift energy efficiency ratings klJ (FLC_1)

  • standby lift energy efficiency ratings klC (FLC_2)

  • operational equipment effectiveness of the lift wc, wj (FLC_3)

  • lift energy efficiency ratings kl (MOD_1)

Fig. 2
figure 2

Lift energy efficiency estimator

Incorporating a number of controllers in the estimator allowed for reducing the number of fuzzy rules.

Results determined in the data processing block in hourly intervals yield the running and standby lift energy efficiency and the lift energy efficiency ratings, expressed by numerical values ranging from 0 to 1, where 0 represents the best-in-class system and 1 the least favourable result. Numerical values can be assigned letter symbols used in other energy efficiency labelling systems (from A to G, where A represents the best-in-class, G represents the least favourable result). The energy efficiency classification can be also defined by a two-term expression, the first term pertaining to the running efficiency rating, the other to the standby energy efficiency ratings (for instance A/G).

Running lift energy efficiency klJ is not constant as it varies with changing performance parameters. In the estimation model considered in this study, it is determined in the block FLC_1 (Fig. 2). The input data to the fuzzy model is the running energy performance factor FJ derived from Formula (2), the membership function is shown in Fig. 3. Critical values of intervals are those specified in (VDI 4707-1 2009). The membership function for the model output (running lift energy efficiency klJ) is shown in Fig. 3. The dependence of the output variable (running lift energy efficiency klJ) on the input variable FJ for the developed fuzzy model is shown in Fig. 4.

Fig. 3
figure 3

Membership functions of the input (left-hand side) and output (right-hand side) of the fuzzy estimator of running lift energy efficiency

Fig. 4
figure 4

Output variable (running lift energy efficiency klJ) vs input variable (running energy performance factor FJ)

The lift standby energy efficiency klC, dependent on energy consumption during the standby and idle time, is determined in the block FLC_2 (Fig. 2). The input parameter in the model is the average standby active power PC, derived from Formula (3) and the membership function associated with this variable is shown in Fig. 5. The critical values of intervals are those specified in (VDI 4707-1 2009).

Fig. 5
figure 5

Membership functions of the input (left-hand side) and output (right-hand side) of the fuzzy estimator of standby lift energy efficiency

The membership function associated with the output variable and the standby lift energy efficiency rating is illustrated in Fig. 5. This function is the same as in the calculations of running energy efficiency. The dependence of the output variable (standby lift energy efficiency rating klC) on the input variable PC for the considered fuzzy model is shown in Fig. 6.

Fig. 6
figure 6

Output variable (standby lift energy efficiency klC) vs input variable (standby energy performance factor PC)

The overall lift energy efficiency rating kl is the resultant per 1 h of the running energy efficiency rating klJ, standby energy efficiency rating PC, running operational equipment efficiency wJ and standby equipment efficiency wC. Its value varies with performance parameters of the lift and the ratio of non-running to running time. The operational equipment effectiveness factor incorporated in the energy efficiency classification system is dependent on the running time, energy consumption by the drive, energy consumption by the entire lift, load carried and distance travelled within the specified time. The operational equipment effectiveness is determined in the block FLC_3 (Fig. 2). Input parameters in the fuzzy model are as follows:

  • iE is the ratio of energy used by the driving unit to energy expended by the entire lift installation per 1 h (derived from Formula (4)),

  • iH is the ratio of distance travelled by the running lift per 1 h to the maximal possible distance travelled by the lift in 1 h and under the maximal loading (Formula (5)),

  • iQ is the ratio of load mass (m) carried by the running lift per 1 h to the maximal possible mass that can be carried in 1 h, derived from Formula (6).

Two output parameters are as follows:

  • operational equipment effectiveness of the running lift (wJ), which becomes 0 when the lift is idle and 1 when the operational effectiveness of the running lift is maximal in terms of distance travelled, carried load and the operating mode,

  • operational equipment effectiveness in the standby mode (wC), which becomes 0 when no standby occurs (the lift is running all the time) and 1 during standby mode operation occurs (no running).

In the model outlined in this study, the set of rules is complementary (i.e. all possibilities are accounted for), comprising 125 rules constructed by the heuristic method utilising the trial and error approach and the expert’s knowledge.

In the fuzzy model providing the procedure to find operational equipment effectiveness of the lift, the dependence of output variables (wJ and wC) on input variables is shown in Figs. 7 and 8 and the obtained control surfaces confirm the adequacy of the membership functions and fuzzy rules.

Fig. 7
figure 7

Output variable (operational equipment effectiveness of the running lift wJ) vs input variables: the running distance factor iH and energy consumption by the drive iE for the constant value of the lifting capacity factor iQ

Fig. 8
figure 8

Output variable (operational equipment effectiveness in the standby mode wC) vs input variables: the running distance factor iQ and loading factor iH, for the constant value of the lifting capacity factor iE

In further step of the calculation procedure, the operational equipment effectiveness factors are expressed in the block MOD_1 (Fig. 2) as weights needed to find the weighted average of the running lift energy efficiency klJ determined in the block FLC_1 and the standby lift energy efficiency klC determined in the block FLC_2.

$$ kl=\frac{kl_C\bullet {w}_C+{kl}_J\bullet {w}_J}{w_C+{w}_J} $$
(7)

The result, expressed as the lift energy efficiency rating kl, is used in the final energy efficiency classification and certification procedure classifying lift installations according to their energy performance.

As stated in the objectives of the energy efficiency classification system, the energy efficiency rating of an installation varies with the lift performance parameters. That is why the final result is given as variations of kl within hourly time intervals throughout the weekly period in which energy performance of the lift and operating parameters are registered. The average value klS is obtained, representing the medium energy efficiency rating.

Verification of the energy efficiency estimator

The verification procedure was conducted on the lift installations in one of the buildings of the AGH-UST. Operating and energy performance parameters of the lift were registered using a portable data acquisition system (Krakowski et al. 2015). The data acquisition system PIP-J6 was connected to the signal conditioning unit connected to the lift drive and control system. The diversity of control systems available in passenger lifts and the number of parameters to be registered necessitated the design and engineering of two data acquisition systems for each lift installation. The first system was installed in the machinery room (Fig. 9) and connected to the drive and control systems and to the lift drive; the other unit was positioned on top of the lift car (Fig. 10) to enable the recording of energy performance parameters of car subassemblies as well as operating parameters, such as lift car loading. Measurement data yield the characteristics required for energy efficiency classification procedure: energy performance and operational parameters are summarised in Table 1.

Fig. 9
figure 9

Data acquisition system in the machinery room

Fig. 10
figure 10

Data acquisition system on top of the lift car

The data registered in accordance with the outlined energy efficiency classification procedure yield the energy efficiency ratings of the lift installation. Accordingly, the values were determined representing the energy efficiency variations during a 7-day duty cycle. Figure 11 shows the variations of the running energy efficiency ratings of the lift (klJ), and variations of the standby lift energy efficiency (klC) are illustrated in Fig. 12. Figure 13 shows the operational equipment effectiveness of the running lift (wJ and in the standby mode wC). Figure 14 shows the final result of the classification procedure expressed as the lift energy efficiency class (kl). It is derived as the weighted average of the running and standby energy efficiency, the weight being taken as the operational equipment effectiveness.

Fig. 11
figure 11

Running mode lift energy efficiency ratings klJ per 1 h in a 7-day duty cycle

Fig. 12
figure 12

Standby mode energy efficiency ratings klC per 1 h in a 7-day duty cycle

Fig. 13
figure 13

Operational equipment effectiveness of the running lift wJ and in the standby wC per 1 h in a 7-day duty cycle

Fig. 14
figure 14

Lift energy efficiency ratings kl per 1 h in a 7-day duty cycle

The adopted energy efficiency classification system allowed for finding the medium energy efficiency ratings of a lift on each separate day (Table 3) and for the entire week (Table 4). Basing on the relevant ranges expressing the energy efficiency ratings and corresponding symbols, energy efficiency classes are labelled with letter symbols. Following the analysis of a weekly duty cycle and energy performance and operating parameters registered within that period, the energy efficiency of the investigated lift was rated as class D. The running energy efficiency was rated as class D, the standby efficiency as class C.

Table 3 Energy efficiency classification ratings obtained by the outlined method
Table 4 Energy efficiency classification within a weekly duty cycle

The results were obtained for 1 week of service of the lift. Measurements were taken for 10 weeks, allowing the uncertainty levels to be determined (Table 4) and demonstrating that a weekly duty cycle well captures the repeatability patterns of the lift usage; hence, the results can be considered reliable.

Energy consumption comparison and discussion

Two main energy efficiency classification methods that are currently used: VDI 4707-1 guideline ISO 25745-2 standard, based on the energy consumption estimated on measurements (running energy consumption of reference cycle and short cycle, standby power) and assumed or measured values and factors dependent on building type describing model and usage intensity, (e.g. number of trips, running time, standby time, average travel distance, average car load, load factor, time ratios of standby mode). Such approach in case of some devices may lead to inadequate and not reliable energy consumption value (Tukia et al. 2016a; Krakowski and Ruta 2018) which in consequence leads to inaccurate energy efficiency classification. More accurate methods of establishing energy consumption of elevators are proposed by other authors, for example Tukia et al. 2016a rely on measuring the energy consumption of most prevailing day types and linearly extrapolating the annual consumption.

Total, running and standby daily average measured and calculated energy consumption for the analysed device according to VDI 4707 and ISO 25745-2 are shown in Fig. 15. These values have been counted based on construction data specific for the device (Table 5), measurements performed according to ISO 25745-1 (Table 6) as well as values and factors specified in the guidelines and counted based on measured operation parameters (Table 7).

Fig. 15
figure 15

Total, running and standby daily average measured and calculated (according to VDI 4707 and ISO 25745-2) energy consumption

Table 5 Technical specification of monitored lift
Table 6 Data determined by measurements (according to ISO 25745-1)
Table 7 Average daily traffic parameters

In the analysed device, even assuming actual parameters describing lift operation leads to inaccurate energy consumption value. Energy consumption in standby mode is similar to the measurements. Significant difference occurs however in energy consumed in running mode, which is 28% of measured value in case of calculations according to VDI, 63% in case of VDI monitored, 59% for ISO and 40% according to ISO monitored.

Using VDI and ISO in some instances may cause that the results of energy consumption calculations may be inaccurate. Even assumption of measured operating parameters in calculations may not lead to establishing accurate value of energy consumption, which is crucial in energy efficiency classification process. Devices which operation is similar to model assumed in guidelines will have reduced uncertainty of calculations and their classification will be defined properly. On the other hand, devices deviating with their operating specifics from this proposed in the model will be classified as better or worse than in reality.

Defined energy efficiency class of the device is not constant and depends on construction and operating parameters. Apart from knowing the accurate value of energy consumption, to determine the class, the travel distance and load to which this energy was used need to be identified. In the VDI and ISO methods, these values are hypothetical and identical for particular group of devices. Thus, it is possible that commonly used operation model dedicated for particular location will be inaccurate for some devices.

Proposed approach as opposed to VDI and ISO methods, which are estimators of energy consumption and energy efficiency classification, is a method basing on measures performed in a weekly operating cycle. Due to multi-dimensionality of analysed objects of incomplete model, large number of variables impacting the final result and significant diversity of objects analysed, it has been decided to use fuzzy logic tool basing on the results of measures performed on a real object. This approach enabled easier analysis of multi-dimensional data, adopting common criteria and obtaining comparable precision of final results.

Using measured values of energy and operating parameters is resulting in receiving actual exploitation model of lift. It is possible to determine the efficiency of lift during its operation together with the parameters changing during the operation. Usage factor of the lift which was introduced can be determined in any time interval and that is why it takes into account the changing operating conditions of its work. This enables determination of the efficiency of the lift in a particular time interval, e.g. hour, period of intensive or low exploitation. The adopted model is characteristic only for the device under consideration. As a consequence, this approach enables a reliable and accurate completion of the certification process in a repeatable manner and with similar uncertainty.

Conclusions

When evaluating lifts and escalators, their energy performance and operating parameters measured on a real object are of particular importance. The developed method of lift energy efficiency classification relies on energy performance and operating parameters of lift installations registered over a weekly duty cycle, with the use of purpose-built measurement system. Pertinent parameters registered over a 7-day cycle provide reliable data for energy efficiency assessment, enable the operating parameters to be adjusted to the specificity of the lift location, allowing an objective comparative overview of lift installations. In the proposed approach, the energy efficiency class varies with its operational equipment effectiveness of the lift installation. The estimator of the energy efficiency classification is constructed using the fuzzy logic approach.