Skip to main content
Log in

Experimental study on the thermal performance of a traditional house with one-sided wind catcher during summer and winter

  • Original Article
  • Published:
Energy Efficiency Aims and scope Submit manuscript

Abstract

The Nagapattinam district lies on the east coast to the south of Cuddalore and is bordered by the Bay of Bengal. The general geological formation of the district is plain and coastal. Energy conservation issues and environmental problems in recent years have increased interest in traditional architecture which is well known for its energy saving designs. This paper presents the quantitative evaluation of traditional buildings in the coastal region of Nagappattinam during summer and winter periods with the custom-made instrument called Mini-meteorological station to understand the various solar passive elements used in the traditional buildings that provide thermal comfort. In this paper, the comparison of thermal performance during winter and summer is explained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15

Similar content being viewed by others

References

  • Auliciems, A. (1981). Towards a psycho physiological model of thermal perception. International Journal of Biometeorology, 25(2), 109–122.

    Article  Google Scholar 

  • A'zami, A., Yasrebi, S.H., & Salehipoor, A. (2005). International conference, passive and low energy cooling 613 for the built environment. Santorini, Greece Climatic responsive architecture in hot and dry regions of Iran, May 2005

  • Bouden, C., & Ghrab, N. (2005). An adaptive thermal comfort model for the Tunisian context: a field study results. Energy and Buildings, 37(9), 952–963.

    Article  Google Scholar 

  • Dili, A. S., Naseer, M. A., & Zacharia Varghese, T. (2010). Passive control methods of Kerala traditional architecture for a comfortable indoor environment: a comparative investigation during winter and summer. Building and Environment, 45, 1134–1143.

    Article  Google Scholar 

  • El-Shorbagy, A.M. (2003) Design with nature: wind catcher as a paradigm of natural ventilation device in buildings. International Journal of Civil & Environmental Engineering, 10(03), 1–5.

    Google Scholar 

  • Fathy, H. (1986). Natural energy and vernacular architecture: Principles and examples with reference to hot arid climates. Chicago: The University of Chicago press.

  • Feriadi, H., & Wong, N. H. (2004a). Thermal comfort for naturally ventilated houses in Indonesia. Energy and Buildings, 36(7), 614–626.

    Article  Google Scholar 

  • Feriadi, H., & Wong, N. H. (2004b). Thermal comfort for naturally ventilated houses in Indonesia. Energy and Buildings, 36, 614–626.

    Article  Google Scholar 

  • Helena, C. (1998). Bioclimatism in vernacular architecture. Renewable and Sustainable Energy Reviews, 2(1–2), 67–87.

    Google Scholar 

  • International Conference, Passive and Low Energy Cooling 699 for the Built Environment. (2005). Santorini, Greece Traditional Indian architecture — The future solar buildings D. Vyas School of Architecture. India: IPS Academy.

    Google Scholar 

  • International Energy Agency. (1998) Online Source, http://www.iea.org.

  • Koeinsberger, O.H., Ingersoll, T.G., Mayhew, A., & Szokolay, S.V. (1975). Manual of tropical housing and building – climatic design. India: Orient Longman.

  • Krishnan, A., Baker, A., Yannas, N., & Szokolay, S. V. (2001). Climate responsive architecture — a design hand book for energy efficient buildings. New Delhi: Tata McGraw-Hill.

    Google Scholar 

  • Montazeri, H., & Azizian, R. (2010). Experimental study on natural ventilation performance of one-sided wind catcher. Building and Environment, 45, 320–329.

    Article  Google Scholar 

  • Olesen, B. W., & Parsons, K. C. (2002). Introduction to thermal comfort standards and to the proposed new version of EN ISO 7730. Energy and Buildings, 34(6), 537–548.

    Article  Google Scholar 

  • Paradise, C., & Forster W. (1998) The vernacular as a model for sustainable design. Cardiff, Wales: Welsh School of Architecture, Cardiff University.

  • PLEA (2006). The 23rd Conference on passive and low energy architecture, Geneva, Switzerland, 6–8 September 2006.

  • Radhakrishnan, S., Shanthi Priya, R., Nagan, S., & Sundarraja, M. C. (2011). Climate responsive traditional architecture of Chettinadu Housing in Tamilnadu — a qualitative and quantitative analysis during summer. International Journal of Ventilation, 10(1), 42.

    Google Scholar 

  • Singh, M. K., Mahapatra, S., & Atreya, S. K. (2010). Thermal performance study and evaluation of comfort temperatures in vernacular buildings of North-East India. Building and Environment, 45, 320–329.

    Article  Google Scholar 

Download references

Acknowledgment

The authors extend sincere gratitude to Mr. Kandavellu of sikkal, Nagappattinam for his kind co-operation in the conduct of the investigation. The authors also extend sincere gratitude to Dr. V. Abhai Kumar, Principal, Thiagarajar College of Engineering, Madurai, Tamilnadu for providing necessary instruments for this research. The authors also would like to acknowledge Ms. L. Vijayalakshmi for assisting me in documenting the traditional buildings. We also acknowledge Mr. Sreejith T.S., Production Executive of EMCON, Cochin, Kerala for fabrication of the equipment setup, A.E.S (architectural evaluation system). The authors also would like to sincerely acknowledge the sources/references which were helpful for my Research works.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Shanthi Priya.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shanthi Priya, R., Sundarraja, M.C. & Radhakrishnan, S. Experimental study on the thermal performance of a traditional house with one-sided wind catcher during summer and winter. Energy Efficiency 5, 483–496 (2012). https://doi.org/10.1007/s12053-012-9155-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12053-012-9155-9

Keywords

Navigation