Abstract
Sulphur Hexafluoride (SF6) is generally found to be very sensitive to field perturbations such as those caused by conductor surface imperfections and by conducting particle contaminants. A study of CIGRE group suggests that 20% of failures in Gas Insulated Substations (GIS) is due to the existence of various metallic contaminations in the form of loose particles. The presence of contamination can therefore be a problem with gas-insulated substations operating at high fields. If the effects of these particles could be eliminated, then this would improve the reliability of compressed gas insulated substation. It would also offer the possibility of operating at higher fields to affect a potential reduction in the GIS size with subsequent savings in the cost of manufacture and installation. The purpose of this paper is to develop techniques, which will formulate the basic equations that will govern the movement of metallic particles like aluminum, silver and copper in a bus duct. Simulation is carried out on particle movement with balanced and unbalanced voltages and the results have been presented and analysed.
Similar content being viewed by others
References
Anis H and Srivastava K D 1989 Breakdown characteristics of dielectric coated electrodes in sulphur hexafluoride gas with particle contamination. Sixth International Symposium on High Voltage Engineering Paper No. 32.06, New Orleans, LA, USA
Christophorou L G, Olthoff J K, Van Brunt R J 1997 SF6 and the electric power industry. IEEE Electrical Insulation Magazine DEIS 20-24
Felici N J 1966 Forces et charges de petits objects en contact avec une electrode affectee d’un champ electrique. Revue generale de I’ electricite 1145–1160
NageshKumar G V, Amarnath J, Singh B P, Srivastava K D 2007 Electric field effect on metallic particle contamination in a common enclosure gas insulated bus duct. IEEE Transactions on Dielectrics and Electrical Insulation 14(2): 334–340
Prakash K S, Srivastava K D, Morcos M M 1997 Movement of particles in compressed SF6 GIS with dielectric coated enclosure. IEEE Transactions on Dielectrics and Electrical Insulation 4: 344–347
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nagesh Kumar, G.V., Amarnath, J., Singh, B.P. et al. Influence of unbalanced voltages on the movement of metallic particle in a three phase common enclosure gas insulated busduct. Sadhana 35, 393–406 (2010). https://doi.org/10.1007/s12046-010-0028-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12046-010-0028-7