Influence of unbalanced voltages on the movement of metallic particle in a three phase common enclosure gas insulated busduct

  • Published:
Sadhana Aims and scope Submit manuscript

Abstract

Sulphur Hexafluoride (SF6) is generally found to be very sensitive to field perturbations such as those caused by conductor surface imperfections and by conducting particle contaminants. A study of CIGRE group suggests that 20% of failures in Gas Insulated Substations (GIS) is due to the existence of various metallic contaminations in the form of loose particles. The presence of contamination can therefore be a problem with gas-insulated substations operating at high fields. If the effects of these particles could be eliminated, then this would improve the reliability of compressed gas insulated substation. It would also offer the possibility of operating at higher fields to affect a potential reduction in the GIS size with subsequent savings in the cost of manufacture and installation. The purpose of this paper is to develop techniques, which will formulate the basic equations that will govern the movement of metallic particles like aluminum, silver and copper in a bus duct. Simulation is carried out on particle movement with balanced and unbalanced voltages and the results have been presented and analysed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Anis H and Srivastava K D 1989 Breakdown characteristics of dielectric coated electrodes in sulphur hexafluoride gas with particle contamination. Sixth International Symposium on High Voltage Engineering Paper No. 32.06, New Orleans, LA, USA

  • Christophorou L G, Olthoff J K, Van Brunt R J 1997 SF6 and the electric power industry. IEEE Electrical Insulation Magazine DEIS 20-24

    Google Scholar 

  • Felici N J 1966 Forces et charges de petits objects en contact avec une electrode affectee d’un champ electrique. Revue generale de I’ electricite 1145–1160

  • NageshKumar G V, Amarnath J, Singh B P, Srivastava K D 2007 Electric field effect on metallic particle contamination in a common enclosure gas insulated bus duct. IEEE Transactions on Dielectrics and Electrical Insulation 14(2): 334–340

    Article  Google Scholar 

  • Prakash K S, Srivastava K D, Morcos M M 1997 Movement of particles in compressed SF6 GIS with dielectric coated enclosure. IEEE Transactions on Dielectrics and Electrical Insulation 4: 344–347

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. V. Nagesh Kumar.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nagesh Kumar, G.V., Amarnath, J., Singh, B.P. et al. Influence of unbalanced voltages on the movement of metallic particle in a three phase common enclosure gas insulated busduct. Sadhana 35, 393–406 (2010). https://doi.org/10.1007/s12046-010-0028-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12046-010-0028-7

Keywords

Navigation