Skip to main content

Advertisement

Log in

Analysis and performance of novel and highly efficient electronic ballast operating at unity-power-factor

  • Published:
Sadhana Aims and scope Submit manuscript

Abstract

This paper presents the electronic ballast, in which the coupling inductors are used to inject the current to the dc-bus capacitors, to boost the dc-bus voltage and to filter out the ripples from input line current. The current injection coupling inductor injects its stored energy to the dc-bus capacitors in every switching half cycle. Whereas, the boost coupling inductor keeps the dc-bus voltage always above the peak of ac input voltage. Therefore, the proposed ballast maintains unity-power-factor and high efficiency with ripple-free input current over wide range of input line voltage in case of worst regulation. A symmetrical half-bridge inverter is used to drive the fluorescent lamps. The experimental results of the laboratory prototype ballast for 2 × 36 W fluorescent lamps operating at 50 kHz are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Almeida M Co, Simonetti D S L, Vieira J L F 1998 High-power-factor electronic ballast operating in critical conduction mode. IEEE Trans. power Electron. 13: 93–101

    Article  Google Scholar 

  • Almeida M Co, Simonetti D S L, Vieira J L F 2000 High-power-factor electronic ballast based on a single power processing stage. IEEE Trans. Ind. Electron. 47: 809–820

    Article  Google Scholar 

  • Borghate V B, Suryawanshi H M, Ramteke M R, Renge M M 2006 Electronic ballast with unity power factor based on current injection technique. 37th IEEE International Power Electronics Specialist Conference-PESC-06, Jeju, Corea, 3314–3319

  • Brumatti M, Almeida M Co, Simonetti D S L, Vieira J L F 2005 Single stage self-oscillating HPF electronic ballast. IEEE Trans. Ind. Appl. 41: 735–741

    Article  Google Scholar 

  • De Oliveira R, Brioschi, Vieira J L F 1998 High power factor electronic ballast with constant DC-link voltage. IEEE Trans. Power Electron. 13: 1030–1037

    Article  Google Scholar 

  • Do H L, Kwon B H 2003 Single-stage line-coupled half-bridge ballast with unity power factor and ripple-free input current using coupled inductor. IEEE Trans. Ind. Electron. 50: 1259–1266

    Article  Google Scholar 

  • Kazimierczuk M K, Szaraniec W 1993 Electronic ballast for fluorescent lamp. IEEE Trans. Power Electron. 8: 386–395

    Article  Google Scholar 

  • Lin C S, Chen C L 1998 Single-switch soft-switching electronic ballast with high input power factor. IEE Proc. Electr. Power Appl. 145: 345–350

    Article  Google Scholar 

  • Spangler J, Behera A K 1991 Power factor correction techniques used for fluorescent lamp ballast. in Conf. Rec. IEEE-IAS Annaul Meeting 1836–1841

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. B. Borghate.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Borghate, V.B., Suryawanshi, H.M. & Dhomane, G.A. Analysis and performance of novel and highly efficient electronic ballast operating at unity-power-factor. Sadhana 33, 523–535 (2008). https://doi.org/10.1007/s12046-008-0040-3

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12046-008-0040-3

Keywords

Navigation