Skip to main content

Advertisement

Log in

Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study

  • Published:
Pramana Aims and scope Submit manuscript

Abstract

Carbon nanotube-based transmission X-ray tubes are widely used in different applications including mammography and X-ray fluorescence (XRF) experiment. Molybdenum (Mo) is one of the suitable target materials for this type of tube. In this paper, we used a well-known simulator, Geant4, to achieve some of the parameters of the Mo target. The optimum thickness for maximum production of usable X-ray from Mo target was obtained when it was exposed to the electron beam with an energy of 50 keV. In addition, according to the results, hemisphere geometry was recommended for the target at least for XRF application. By increasing target thickness, Mo acts as a filter resulting in limited X-ray energy. For estimating the target’s temperature generation, the amount of deposited energy was also evaluated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. M M Nasseri, Nucl. Instrum. Methods B 358, 255 (2015)

    Article  ADS  Google Scholar 

  2. J Zhang et al, Appl. Phys. Lett. 86(18), 4104 (2005)

    Google Scholar 

  3. S H Heo, A Ihsan and S O Cho, Appl. Phys. Lett. 90(18), 3109 (2007)

    ADS  Google Scholar 

  4. R H Baughman, Science 297, 787 (2010)

    Article  ADS  Google Scholar 

  5. J W Jeong et al, Appl. Phys. Lett. 102(02), 3504 (2013)

    Google Scholar 

  6. B Sitharaman et al, Carbon 53, 90 (2013)

    Article  Google Scholar 

  7. H Sugie et al, Appl. Phys. Lett. 78(25), 78 (2001)

    ADS  Google Scholar 

  8. A Ihsan, S H Heo and S O Cho, Nucl. Instrum. Methods B 264, 371 (2007)

    Article  ADS  Google Scholar 

  9. A Ihsan, S H Heo and S O Cho, Nucl. Instrum. Methods B 267, 3566 (2009)

    Article  ADS  Google Scholar 

  10. C Jensen, Adv. X-Ray Anal. 47 (2004)

  11. M M Nasseri, Nucl. Eng. Technol. 48, 795 (2016)

    Article  Google Scholar 

  12. Y Cheng et al, Rev. Sci. Instrum. 75, 3264 (2004)

    Article  ADS  Google Scholar 

  13. X Qian et al, Med. Phys. 39(4), 2090 (2012)

    Article  Google Scholar 

  14. S Bichlmeier et al, X Ray Spectrom. 30(1), 8 (2001)

    Article  ADS  Google Scholar 

  15. D M Tucker, G T Barnes and X Z Wu, Med. Phys. 18, 3 (1991)

    Google Scholar 

  16. A Ihsan et al, Nucl. Instrum. Methods B 269, 1053 (2011)

    Article  ADS  Google Scholar 

  17. G F Knoll, Radiation detection and measurement, 3rd edn (John Wiley & Sons, Inc, 1999)

  18. http://geant4.web.cern.ch/geant4/

  19. S Chauvie et al, Conference Record 2004 IEEE Nuclear Science Symposium (Rome, Italy, 2004) Vol. 3, p. 1881

    Book  Google Scholar 

  20. S Chauvie et al, IEEE Nuclear Science Symposium Conference Record (New Jersey, USA, 2006), p. 1511

    Google Scholar 

  21. S T Perkins et al, UCRL-50400, Vol. 31, 1997, https://doi.org/10.2172/5691165

  22. P Rodrigues et al, IEEE Trans. Nucl. Sci. 51(4), 1412 (2004)

    Article  ADS  Google Scholar 

  23. J Sempau, J M Fernández Varea, E Acosta and F Salvat, Nucl. Instrum. Methods B 207(2), 107 (2003)

    Article  ADS  Google Scholar 

  24. K Wang et al, IEEE Trans. Radiat. Plasma Med. Sci. 2(5), 452 (2018), https://doi.org/10.1109/TRPMS.2018.2849099

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammad Mehdi Nasseri.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nasseri, M.M. Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study. Pramana - J Phys 92, 54 (2019). https://doi.org/10.1007/s12043-019-1718-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s12043-019-1718-2

Keywords

PACS Nos

Navigation