Abstract
Carbon nanotube-based transmission X-ray tubes are widely used in different applications including mammography and X-ray fluorescence (XRF) experiment. Molybdenum (Mo) is one of the suitable target materials for this type of tube. In this paper, we used a well-known simulator, Geant4, to achieve some of the parameters of the Mo target. The optimum thickness for maximum production of usable X-ray from Mo target was obtained when it was exposed to the electron beam with an energy of 50 keV. In addition, according to the results, hemisphere geometry was recommended for the target at least for XRF application. By increasing target thickness, Mo acts as a filter resulting in limited X-ray energy. For estimating the target’s temperature generation, the amount of deposited energy was also evaluated.
Similar content being viewed by others
References
M M Nasseri, Nucl. Instrum. Methods B 358, 255 (2015)
J Zhang et al, Appl. Phys. Lett. 86(18), 4104 (2005)
S H Heo, A Ihsan and S O Cho, Appl. Phys. Lett. 90(18), 3109 (2007)
R H Baughman, Science 297, 787 (2010)
J W Jeong et al, Appl. Phys. Lett. 102(02), 3504 (2013)
B Sitharaman et al, Carbon 53, 90 (2013)
H Sugie et al, Appl. Phys. Lett. 78(25), 78 (2001)
A Ihsan, S H Heo and S O Cho, Nucl. Instrum. Methods B 264, 371 (2007)
A Ihsan, S H Heo and S O Cho, Nucl. Instrum. Methods B 267, 3566 (2009)
C Jensen, Adv. X-Ray Anal. 47 (2004)
M M Nasseri, Nucl. Eng. Technol. 48, 795 (2016)
Y Cheng et al, Rev. Sci. Instrum. 75, 3264 (2004)
X Qian et al, Med. Phys. 39(4), 2090 (2012)
S Bichlmeier et al, X Ray Spectrom. 30(1), 8 (2001)
D M Tucker, G T Barnes and X Z Wu, Med. Phys. 18, 3 (1991)
A Ihsan et al, Nucl. Instrum. Methods B 269, 1053 (2011)
G F Knoll, Radiation detection and measurement, 3rd edn (John Wiley & Sons, Inc, 1999)
S Chauvie et al, Conference Record 2004 IEEE Nuclear Science Symposium (Rome, Italy, 2004) Vol. 3, p. 1881
S Chauvie et al, IEEE Nuclear Science Symposium Conference Record (New Jersey, USA, 2006), p. 1511
S T Perkins et al, UCRL-50400, Vol. 31, 1997, https://doi.org/10.2172/5691165
P Rodrigues et al, IEEE Trans. Nucl. Sci. 51(4), 1412 (2004)
J Sempau, J M Fernández Varea, E Acosta and F Salvat, Nucl. Instrum. Methods B 207(2), 107 (2003)
K Wang et al, IEEE Trans. Radiat. Plasma Med. Sci. 2(5), 452 (2018), https://doi.org/10.1109/TRPMS.2018.2849099
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nasseri, M.M. Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study. Pramana - J Phys 92, 54 (2019). https://doi.org/10.1007/s12043-019-1718-2
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s12043-019-1718-2