Abstract

The powder diffractometer and Hi-Q diffractometer at Dhruva reactor make use of five identical 1-D position sensitive detectors (PSDs) to scan scattering angles in the range 3° to 140°. In order to improve the overall throughput of these spectrometers, it is planned to install a bank of 15 high-efficiency and high-resolution PSDs arranged in three layers with five PSDs in each layer. With each high pressure PSD (3He 10 bar + Kr 2 bar) showing the efficiency gain of 1.8 at 1.2 Å, detector bank is expected to show overall gain of 5.5 times the present detection efficiency and reduction in data collection time by equivalent factor. The 1-D PSDs are developed in batches of five, and are characterized so that all PSDs operate at uniform parameters such as position resolution, uniformity of efficiency and linearity of response. Position spectrum indicates the differential position resolution to be ∼1 mm and integral position resolution to be 3–4 mm. Broadening of position spectrum at the extreme end of sensitive length of PSD is analysed using fine shift of the beam. Dependence of position resolution and dynamic range of output pulse on the input impedance of pre-amplifier is also presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G F Knoll, Radiation detection and measurement, II edition (John Wiley and Sons, 1989)

  2. P Convert and J B Forsyth (eds), Position sensitive detection for thermal neutrons (Academy Press, London, 1983)

    Google Scholar 

  3. S S Desai and A M Shaikh, Rev. Sci. Instrum. 78, 023304 (2007)

    Article  ADS  Google Scholar 

  4. S S Desai, Development and performance study of position sensitive detectors for X-ray and neutron scattering applications, Ph.D. Thesis (University of Mumbai, 2006)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. M. Shaikh.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Desai, S.S., Shaikh, A.M. Performance studies on high pressure 1-D position sensitive neutron detectors. Pramana - J Phys 71, 1183–1188 (2008). https://doi.org/10.1007/s12043-008-0244-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12043-008-0244-4

Keywords

PACS Nos

Navigation