Skip to main content
Log in

Effect of adding Ar gas on the pulse height distribution of BF3-filled neutron detectors

  • Published:
Pramana Aims and scope Submit manuscript

Abstract

Boron trifluoride (BF3) proportional counters are used as detectors for thermal neutrons. They are characterized by high neutron sensitivity and good gamma discriminating properties. Most practical BF3 counters are filled with pure boron trifluoride gas enriched up to 96% 10B. But BF3 is not an ideal proportional counter gas. Worsening of plateau characteristics is observed with increasing radius due to impurities in gas. To overcome this problem, counters are filled with BF3 with an admixture of a more suitable gas such as argon. The dilution of BF3 with argon causes a decrease in detection efficiency, but the pulse height spectrum shows sharper peaks and more stable plateau characteristics than counters filled with pure BF3. The present investigations are undertaken to study the pulse height distribution and other important factors in BF3+Ar filled signal counters for neutron beam applications. Tests are performed with detectors with cylindrical geometry filled with BF3 gas enriched in 10B to 90%, and high purity Ar in different proportions. By analysing pulse height spectra, a value of 6.1 ± 0.2 has been obtained for the branching ratio of the 10B(n,α) reaction.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. I L Fowler, Rev. Sci. Instrum. 34(7), 731 (1963)

    Article  ADS  Google Scholar 

  2. G F Knoll, Radiation detection and measurement, II edition (John Wiley and Sons, 1989)

  3. R Cervellati and A Kazimierski, Nucl. Instrum. Methods 60, 173 (1968)

    Article  ADS  Google Scholar 

  4. I O Andersson and M Malmskog, Aktiebolaget Atomenergi (Sweden) Report AE-84 (1962)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. M. Shaikh.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Padalakshmi, M., Shaikh, A.M. Effect of adding Ar gas on the pulse height distribution of BF3-filled neutron detectors. Pramana - J Phys 71, 1177–1181 (2008). https://doi.org/10.1007/s12043-008-0243-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12043-008-0243-5

Keywords

PACS Nos

Navigation