Abstract
There are no data available on the use of hand-held X-ray fluorescence (XRF) spectrometry to determine trace element concentrations in veterinary diagnostics. The hand-held XRF spectrometer is easy to use and does not require extensive training for the operator. In Sub-Saharan Africa with few centralised analytical laboratories equipped with expensive apparatus or mass spectrometry capabilities, trace element analysis using the hand-held XRF spectrometer provides an alternative. The objective of this study was to compare ovine hepatic copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), selenium (Se) and zinc (Zn) concentrations as obtained with the hand-held XRF spectrometer to those of a reference laboratory using inductively coupled plasma mass spectrometry (ICP-MS). Thirty ovine livers were obtained from an abattoir; prepared as wet blended and oven-dried samples and analysed. Bayesian correlation was used to assess the correspondence between results from the XRF and ICP-MS analyses. The oven-dried preparation procedure for XRF provided the best correlation with the ICP-MS data. The correlations for Cu and Zn were strong and the XRF method may represent a suitable substitute for ICP-MS analysis. For Mn and Fe the correlations were moderately strong and the XRF method may be suitable. For Mo, the correlation was weak and XRF cannot be recommended. Selenium could not be detected in samples prepared by either method. Hand-held XRF spectrometry was a practical method to determine liver concentrations of specific trace elements under African conditions and may significantly reduce the turn-around time of analysis, but unfortunately the apparatus is expensive.
References
National Research Council (2005) Mineral tolerance of animals. 2nd ed. the National Academies Press, Washington, DC
Failla ML (2003) Trace elements and host defense: recent advances and continuing challenges. J Nutr 133:1443–1447
Bath GS (1979) Enzootic icterus – a form of chronic copper poisoning. J S Afr Vet Assoc 50:3–13
Van Ryssen JBJ (2001) Geographical distribution of the selenium status of herbivores in South Africa. S Afr J Anim Sci 31:1–8
Papachristodoulou C, Stamoulis K, Tsakos P, Vougidou C, Vozikis V, Papadopoulou C, Ioannides K (2015) Liver concentrations of copper, zinc, iron and molybdenum in sheep and goats from northern Greece, determined by energy-dispersive X-ray fluorescence spectrometry. B Environ Contam Tox 94:460–467. https://doi.org/10.1007/s00128-015-1496-6
Mohd-Taufek N, Cartwright D, Davies M, Hewavitharana AK, Koorts P, Shaw PN, Sumner R, Lee E, Whitfield K (2016) The simultaneous analysis of eight essential trace elements in human milk by ICP-MS. Food Anal Method 9:2068–2075. https://doi.org/10.1007/s12161-015-0396-z
Takahashi S, Takahashi I, Sato H, Kubota Y, Yoshida S, Muramatsu Y (2000) Determination of major and trace elements in the liver of Wistar rats by inductively coupled plasma-atomic emission spectrometry and mass spectrometry. Lab Anim 34:97–105
Rowe H, Hughes N, Robinson K (2012) The quantification and application of hand-held energy-dispersive X-ray fluorescence (ED-XRF) in mudrock chemostratigraphy and geochemistry. Chem Geol 324–325:122–131. https://doi.org/10.1016/j.chemgeo.2011.12.023
Nganvongpanit K, Buddhachat K, Brown JL (2016) Comparison of bone tissue elements between normal and osteoarthritic pelvic bones in dogs. Biol Trace Elem Res 171:344–353. https://doi.org/10.1007/s12011-015-0556-4
Nganvongpanit K, Buddhachat K, Piboon P, Klinhom S (2016) The distribution of elements in 48 canine compact bone types using handheld X-ray fluorescence. Biol Trace Elem Res 174:93–104. https://doi.org/10.1007/s12011-016-0698-z
Kruschke JK (2013) Bayesian estimation supersedes the t test. J Exp Psychol 142:573–603. https://doi.org/10.1037/a0029146
R Core Team. The R Project for Statistical Computing, R Foundation http://www.R-project.org/ Accessed 25 February 2017
Tallandini L, Giacobini F, Turchetto M et al (1989) Naturally occurring levels of elements in fishes as determined by PIXE and XRF methods. Nucl Instrum Meth B 40(41):630–634
Kascakova S, Kewish CM, Rouziere S et al (2016) Rapid and reliable diagnosis of Wilson disease using X-ray fluorescence. J Path: Clin Res 2:175–186. https://doi.org/10.1002/cjp2.48
Kempson IM, Henry DA (2010) Determination of arsenic poisoning and metabolism in hair by synchrotron radiation: the case of Phar Lap. Angew Chem Int Edit 49:4237–4240. https://doi.org/10.1002/anie.200906594
Nakazawa E, Ikemoto T, Hokura A, Terada Y, Kunito T, Tanabeb S, Nakai I (2011) The presence of mercury selenide in various tissues of the striped dolphin: evidence from μ-XRF-XRD and XAFS analyses. Metallomics 3:719–725. https://doi.org/10.1039/c0mt00106f
Sanchez HJ, Perez C, Perez RD (1997) XRF analysis of arsenic uptaking in mice organs and tissues. Nucl Instrum Meth B 124:140–142
Funding
This work is based on the research supported in part by the National Research Foundation of South Africa (grant number 103747).
Author information
Authors and Affiliations
Author notes
Daniël E. van Loggerenberg is deceased. This paper is dedicated to his memory.
- Daniël E. van Loggerenberg
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Ethical Approval
All procedures performed in this study were in accordance with the ethical standards of the University of Pretoria. Approval was obtained from the Animal Ethics Committee (V087–16).
Rights and permissions
About this article
Cite this article
van Loggerenberg, D.E., Laver, P.N., Myburgh, J.G. et al. Diagnostic Value of Energy Dispersive Hand-Held X-ray Fluorescence Spectrometry in Determining Trace Element Concentrations in Ovine Liver. Biol Trace Elem Res 190, 358–361 (2019). https://doi.org/10.1007/s12011-018-1546-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12011-018-1546-0