Abstract
Tungsten coil atomic emission spectrometry (WCAES) is used to determine trace levels of Mn (403.1 nm) and Cr (425.5 nm) in cow placenta. All samples were collected in Ilha Solteira, SP, Brazil. The instrumental setup is based on a tungsten filament extracted from 150 W, 15 V microscope light bulbs, a solid state power supply, fused silica lens, crossed Czerny-Turner spectrograph, and a thermoelectrically cooled charge-coupled device detector. The limits of detection (LOD) and quantification (LOQ) for Cr are 2 and 8 μg L−1, and 20 and 60 μg L−1 for Mn, respectively. Recoveries for 0.30 mg L−1 spikes of each analyte were in the range 93.0–103.0%, and relative standard deviation (RSD) was between 6.50 and 7.20% for both elements. Placenta samples were microwave-assisted digested with diluted HNO3 and H2O2 and analyzed by WCAES. The results for Cr and Mn were compared with values obtained by tandem inductively coupled plasma mass spectrometry (ICP-MS/MS). No statistically significant difference was observed between the different methods by applying a paired t test at a 95% confidence level. The average concentrations of Cr and Mn in the placentas evaluated were 0.95 ± 0.22 and 2.64 ± 0.39 μg g−1, respectively. By using a short integration time, LODs for Cr and Mn were lower than values reported by recent works using a similar WCAES system.
Similar content being viewed by others
References
Zhou X, Qu X, Zhao S, Wang J, Li S, Zheng N (2015) Analysis of 22 elements in milk, feed, and water of dairy cow, goat, and buffalo from different regions of China. Biol Trace Elem Res DOI. doi:10.1007/s12011-016-0819-8
Kincaid RL (2011) Assessment of trace mineral status of ruminants: a review. J Anim Sci 77(1–10):2011
Tizioto PC, Gromboni CF, Nogueira ARA, De Araujo Nogueira AR, De Souza MM, De Alvarenga MM, Tholon P, Do Nascimento RA, Tullio RR, Medeiros SR, Nassu RT, De Almeida Regitano LC (2014) Calcium and potassium content in beef: influences on tenderness and associations with molecular markers in Nellore cattle. Meat Sci 96:436–440
Nriagu J, Boughanen M, Linder A, Howe A, Grant C, Rattray R, Vutchkov M, Lalor G (2009) Levels of As, Cd, Pb, Cu, Se and Zn in bovine kidneys and livers in Jamaica. Ecotox Environ Safe 72(2):564–571
Rey-Crespo F, Miranda M, López-Alonso M (2013) Essential trace and toxic element concentrations in organic and conventional milk in NW Spain. Food Chem Toxicol 55:513–518
Schlafer DH, Fisher PJ, Davies CJ (2000) The bovine placenta before and after birth: placental development and function in health and disease. Anim Reprod Sci 60-61(2):145–160
Méndez-Vilas A, Díaz J (2010) Microscopy: science, technology, applications and education, 1st edn. Badajoz, Espanha, p 1039
Graham T, Thurmond M, Mohr C, Holmberg C, Anderson M, Keen C (1994) Relationships between maternal and fetal liver copper, iron, manganese, and zinc concentrations and fetal development in California Holstein dairy cows. J Vet Diagn Investig 6:77–87
Overton TR, Yasui T (2014) Practical applications of trace minerals for dairy cattle. J Anim Sci 92:416–426
Hidiroglou M (1979) Trace element deficiencies and fertility in ruminants: a review. J Dairy Sci 62(8):1195–1206
Kumar V (2015) Effect of minerals on dairy animal reproduction—a review. Int J Livest Res 5(6):1–10
Machado VS, Oikonomou G, Lima SF, Bicalho MLS, Kacar C, Foditsch C, Felippe MJ, Gilbert RO, Bicalho RC (2014) The effect of injectable trace minerals (selenium, copper, zinc, and manganese) on peripheral blood leukocyte activity and serum superoxide dismutase activity of lactating Holstein cows. Vet J 200(2):299–304
Bicalho MLS, Lima SF, Ganda EK, Foditsch C, Meira EBS Jr, Machado VS, Teixeira AGV, Oikonomou G, Gilbert RO, Bicalho RC (2014) Effect of trace mineral supplementation on selected minerals, energy metabolites, oxidative stress, and immune parameters and its association with uterine diseases in dairy cattle. J Dairy Sci 97(7):4281–4295
Vásquez EFA, Herrera IAPN (2003) Concentração plasmática de cortisol, uréia, cálcio e fósforo em vacas de corte mantidas a pasto suplementadas com levedura de cromo durante a estação de monta. Cienc Rural 33(4):743–747
Ceko MJ, Hummitzsch K, Bonner WM, Aitken JB, Spiers KM, Rodgers RJ, Harris HH (2015) Localization of the trace elements iron, zinc and selenium in relation to anatomical structures in bovine ovaries by X-ray fluorescence imaging. Microsc Microanal 21(3):695–705
Sheetal SK, Choudhary SK, Sengupta D (2014) Mineral deficiency predisposes occurrence of retention of placenta in crossbred. Vet World 7(12):1140–1143
Hostetler C, Kincaid R, Mirando M (2003) The role of essential trace elements in embryonic and fetal development in livestock. Vet J 166(1):125–139
Rust JA, Nóbrega JA, Calloway CP Jr, Jones BT (2005) Advances with tungsten coil atomizers: continuum source atomic absorption and emission spectrometry. Spectrochim Acta Part B 60(30):589–598
Rust JA, Nóbrega JA, Calloway CP Jr, Jones BT (2006) Tungsten coil atomic emission spectrometry. Spectrochim Acta Part B 61(2):225–229
Donati GL, Gu JY, Nobrega JA, Calloway CP Jr, Jones BT (2008) Simulateneous determinations of the lanthanides by tungsten coil emission espectrometry. J Anal At Spectrom 23(3):361–366
Gu J, Oliveira SR, Donati GL, Gomes Neto JA, Jones BT (2011) Rugged, portable tungsten coil atomic emission spectrometer. Anal Chem 83(7):2526–2531
Santos LN, Donati GL, Calloway CP Jr, Jones BT, Nóbrega JA (2012) Enzymatic proteolysis and in situ digestion as strategies to determine Cs and Sr in fish by tungsten coil atomic emission spectrometry. J Anal At Spectrom 27:2082–2087
Dancsak SE, Silva SG, Nóbrega JA, Jones BT, Donati GL (2014) Direct determination of sodium, potassium, chromium and vanadium in biodiesel fuel by tungsten coil atomic emission spectrometry. Anal Chim Acta 806(2):85–90
Virgilio A, Nobrega JA, Jones BT, Donati GL (2014) Chemical modification in atomic emission: determination of V in lubricant oils by tungsten coil atomic emission spectrometry. Microchem J 115:58–62
Gonzalez MH, Santos LN (2015) Determination of manganese in sludge, alloy, and soil by tungsten coil atomic emission spectrometry. Anal Lett 48:2434–2445
Goncalves DA, Jiyan G, dos Santos MC, Jones BT, Donati GL (2015) Direct determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometry. J Anal At Spectrom 30(6):1395–1399
Vidal L, Silva SG, Canals A, Nobrega JA (2016) Tungsten coil atomic emission spectrometry combined with dispersive liquid–liquid microextraction: a synergistic association for chromium determination in water samples. Talanta 148:602–608
Donati GL, Jones BT (2011) Development of a novel spectrometric-based temperature probe and the investigation of atomic cloud generation in a tungsten coil atomizer. J Anal At Spectrom 26(4):838–844
Donati GL, Kron BE, Jones BT (2009) Simultaneous determination of Cr, Ga, In and V in soil and water samples by tungsten coil atomic emission spectrometry. Spectrochim Acta Part B 64:559–564
Donati GL (2011) Trends in tungsten coil atomic spectrometry. 1 ed, ProQuest, Cambridge, p 262
Balcaen LEB, Resano FM, Vanhaecke F (2015) Inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS): a powerful and universal tool for the interference-free determination of (ultra)trace elements—a tutorial review. Anal Chim Acta 894:7–19
Nóbrega JA, Pirola C, Fialho LL, Rota G, de Campos JCEKMA, Pollo F (2012) Microwave-assisted digestion of organic samples: how simple can it become? Talanta 98:272–276
Gonzalez MH, Souza GB, Oliveira RV, Forato LA, Nóbrega JA, Nogueira ARA (2009) Microwave-assisted digestion procedures for biological samples with diluted nitric acid: identification of reaction products. Talanta 79:396–401
Donati GL, Callowa CP Jr, Jones BT (2009) Double tungsten coil atomic emission spectrometry: signal enhancement and a new gas phase temperature probe. J Anal At Spectrom 24(8):1105–1110
Virgilio A, Healy CK, Nóbrega JA, Jones BT, Donati GL (2013) Evaluation of atomizer conditioning and pyrolysis and atomization temperature control to improve procedures based on tungsten coil atomic emission spectrometry. Microchem J 110:758–763
Silva SG, Nobrega JA, Jones BT, Donati GL (2014) Magnesium nitrate as a chemical modifier to improve sensitivity in manganese determination in plant materials by tungsten coil atomic emission spectrometry. J Anal At Spectrom 29:1499–1503
Silva SG, Donati GL, Santos LN, Jones BT, Nobrega JA (2013) Cobalt as chemical modifier to improve chromium sensitivity and minimize matrix effects in tungsten coil atomic emission spectrometry. Anal Chim Acta 780:7–12
Junior JBP, Fernandes KG (2011) Studying the distribution of selenium in buffalo and cow’s milk whey. J Braz Chem Soc 22(5):884–890
Goncalves DA, McSweeney T, Santos MC, Bradley TJ, George LD (2016) Standard dilution analysis of beverages by microwave-induced plasma optical emission spectrometry. Anal Chim Acta 909:24–29
Aguiar GFM, Batista BL, Rodrigues JL, Luccas PO, Barbosa F Jr (2012) Evaluation of inductively coupled plasma mass spectrometry for determining Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen samples using a simple sample dilution method. J Braz Chem Soc 23(3):573–580
Edward V (1997) Comparison of signal-to-noise ratios. Anal Chem 69(2):226–234
Long GL, Winefordner JD (1983) Limit of detection a closer look at the IUPAC definition. Anal Chem 55(7):712–724
Miller JC, Miller JN (1984) Statistics for analytical chemistry. Ellis Horwood Lt, Chichester, pp 52–56
Bryan MA, Socha MT, Tomlinson DJ (2004) Supplementing intensively grazed late-gestation and early-lactation dairy cattle with chromium. J Dairy Sci 87:4269–4277
Vargas-Rodriguez CF, Yuan K, Titgemeyer EC, Mamedova LK, Griswold KE, Bradford BJ (2014) Effects of supplemental chromium propionate and rumen-protected amino acids on productivity, diet digestibility, and energy balance of peak-lactation dairy cattle. J Dairy Sci 97(6):3815–3821
Acknowledgements
The authors would like to thank the Department of Chemistry at Wake Forest University and Agilent Technologies for their support to this work. The fellowship provided to D.A.G. by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES, Brazil, Grant No 99999.002566/2014-01) is also greatly appreciated.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Gonçalves, D.A., Soncin, A.C., Donati, G.L. et al. Determination of Trace Elements in Cow Placenta by Tungsten Coil Atomic Emission Spectrometry. Biol Trace Elem Res 178, 228–234 (2017). https://doi.org/10.1007/s12011-016-0926-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12011-016-0926-6