Abstract
In this paper we suggest a general procedure to model tube-shaped stents by CAD, in particular of intravascular coronary kind. The methodology utilisation is highly independent of modelization softwares and enables us to build up careful stent models. These models can be usefully used to perform structural and/or blood fluid dynamic analysis. The procedure is based on particular considerations of Descriptive Geometry that are inspired by the laser cutting technology of the stents. The study is developed by using a hybrid technique of surfaces and solids modelling. The method suggested is illustrated with reference to a class of intracoronary stents cut by laser beam. Some general conclusions show how it is possible to apply the procedure also for modelling of stents manufactured by using welded stainless steel wire.
Similar content being viewed by others
References
Wang, W.Q., Liang, D.K., Yang, D.Z., Qi, M.: Analysis of the transient expansion behaviour and design optimization of coronary stents by finite element method. J. Biomech. 39(1), 21–32 (2006)
Migliavacca, F., Petrini, L., Colombo, M., Auricchio, F., Pietrabissa, R.: Mechanical behaviour of coronary stents investigated through the finite element method. J. Biomech. 35(6), 803–811 (2002)
Liang, D.K., Yang, D.Z., Qi, M., Wang, W.Q.: Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. Int. J. Cardiol. 104(3), 314–318 (2005)
Petrini, L., Migliavacca, F., Auricchio, F., Dubini, G.: Numerical investigation of the intravascular coronary stent flexibility. J. Biomech. 37(4), 495–501 (2004)
Tan, L.B., Webb, D.C., Kormi, K.: A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation. Int. J. Cardiol. 78(1), 51–67 (2001)
Gu, L., Santra, S., Mericle, R.A., Kumar, A.V.: Finite element analysis of covered microstents. J. Biomech. 38(6), 1221–1227 (2005)
ThinkDesign, Think3, Solution for 2D and 3D aided design, Bologna, Italy. http://www.think3.it/it
Dehlaghi, V., Najarian, S., Tafazzoli, S.M.: Effect of stent geometry on phase shift between pressure and flow waveforms in stented human coronary artery. Am. J. Appl. Sci. 5(4), 340–346 (2008)
Briguori, C., Sarais, C., Pagnotta, P., Liistro, F., Montorfano, M., Chieffo, A., Sgura, F., Corvaja, N., Albiero, R., Stankovic, G., Toutoutzas, C., Bonizzoni, E., Di Mario, C., Colombo, A.: In-stent restenosis in small coronary arteries: impact of strut thickness. J. Am. Coll. Cardiol. 40, 403–409 (2002)
Pache, J., Kastrati, A., Mehilli, J., Schühlen, H., Dotzer, F., Hausleiter, J., Fleckenstein, M., Neumann, F.J., Sattelberger, U., Schmitt, C., Müller, M., Dirschinger, J., Schömig, A.: Intracoronary stenting and angiographic results: strut thickness effect on restenosis. J. Am. Coll. Cardiol. 41, 1283–1288 (2003)
Pache, J., Dibra, A., Mehilli, J., Dirschinger, J., Schömig, A., Castrati, A.: Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective randomized trial. Eur. Heart J. 26, 1262–1268 (2005)
Acknowledgments
This work was supported by International Biomedical System S.p.A., Area Science Park, Padriciano, Trieste, Italy.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Muscia, R. Hybrid modelization of intracoronary stents. Int J Interact Des Manuf 8, 305–315 (2014). https://doi.org/10.1007/s12008-014-0226-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12008-014-0226-3