Abstract
Purpose of Review
To explore the efficacy of radio frequency ablation in treating pain in patients with hardware at site of the procedure.
Recent Findings
There is very limited data in literature about this topic. One study performed in 2016 indicated no complications when performing RFA close to hardware in patients with chronic pain conditions.
Summary
Radiofrequency ablation can be safely and effectively performed close to hardware. While heating of the hardware can happen which can theoretically lead to tissue injury or decreased heat going to target nerve, this does not seem to be of clinical significance. More studies are needed to confirm this finding.
Similar content being viewed by others
References
Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance
Bogduk N, editor. Practice guidelines for spinal diagnostic and treatment procedures. San Francisco international Spine Intervention Society. 1st ed. San Francisco: International Spine Intervention Society; 2004.
Nguyen DT, Barham W, Zheng L, Dinegar S, Tzou WS, Sauer WH. Effect of radiofrequency energy delivery in proximity to metallic medical device components. Heart Rhythm. 2015;12(10):2162–9.
Cui W, Fan W, Lu M, Zhang Y, Yao W, Li J, et al. The safety and efficacy of percutaneous intraductal radiofrequency ablation in unresectable malignant biliary obstruction: a single-institution experience. BMC Cancer. 2017;17(1):288.
Steel AW, Postgate AJ, Khorsandi S, Nicholls J, Jiao L, Vlavianos P, et al. Endoscopically applied radiofrequency ablation appears to be safe in the treatment of malignant biliary obstruction. Gastrointest Endosc. 2011;73(1):149–53.
•• Klessinger S. Safety and efficacy of lumbar spine radiofrequency neurotomy in the presence of posterior pedicle screws. Progress in Orthopedic Science. 2016;2(3):30–4 This is a very nice article that confirms the efficacy of RFA in patients with hardware.
Thakur S, Lavito S, Grobner E, Grobner M. Radiofrequency thermal ablation heat energy transfer in an ex-vivo model. Am Surg. 2017;83(12):1373–80.
Bleicher RJ, Allegra DP, Nora DT, Wood TF, Foshag LJ, Bilchik AJ. Radiofrequency ablation in 447 complex unresectable liver tumors: lessons learned. Ann Surg Oncol. 2003;10(1):52–8.
Kruger AJ, Krishna SG. Unexpected outcome following radiofrequency ablation of a malignant biliary stricture. Turk J Gastroenterol. 2018;29(2):230–2.
• Gazelka HM, Welch TL, Nassr A, Lamer TJ. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study. Pain Med. 2015;16(5):877–80 This is a nice study to examine the effect of RFA on hardware.
•• Lamer TJ, Smith J, Hoelzer BC, Mauck WD, Qu W, Gazelka HM. Safety of lumbar spine radiofrequency procedures in patients who have posterior spinal hardware. Pain Med. 2016;17(9):1634–7 This is a good article that examined the efficacy of RFA on hardware in the lumbar spine.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
Alaa A. Abd-Elsayed, Kenneth Fiala, Sean Nguyen, and Jeff VanderWood declare no conflict of interest. Dr. Abd-Elsayed is a consultant for Medtronic, Halyard, StimWave, SpineLoop and Sollis. Dr. Kaye is on the Speakers Bureau for Depomed, Inc. and Merck.
Human and Animal Rights and Informed Consent
This article does not contain any studies with human or animal subjects performed by any of the authors.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This article is part of the Topical Collection on Neuropathic Pain
Rights and permissions
About this article
Cite this article
Abd-Elsayed, A., Fiala, K., Nguyen, S. et al. Safety and Efficacy of Radiofrequency Ablation of the Medial Branch Nerves with Preexisting Spinal Hardware. A Case Series and Review of Literature. Curr Pain Headache Rep 23, 11 (2019). https://doi.org/10.1007/s11916-019-0752-6
Published:
DOI: https://doi.org/10.1007/s11916-019-0752-6