Abstract
In up to 50 % of patients undergoing continuous flow, axial pump, left-ventricular and assist device (LVAD) placement, concomitant procedures are performed. The underlying lesions have a broad spectrum of severity, complexity, and impact on clinical outcomes. This review describes the concomitant lesions often encountered with LVAD implantation and clinical relevance of their repair.
Similar content being viewed by others
References
• Pal JD, Klodell CT, John R, et al. Low operative mortality with implantation of a continuous-flow left ventricular assist device and impact of concurrent cardiac procedures. Circulation. 2009;120:S215–9. This manuscript describes the incidence of concominant surgical proceedures during continuous flow LVAD implant.
• Kirklin JK, Naftel DC, Kormos RL, et al. Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transpl: Off Pub Int Soc Heart Transpl. 2013;32:141–56. This article outlines survival for mechanical pumps. In addition, the indictaions for implantation and complications are described.
McKellar SH, Deo S, Daly RC, et al. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices. J Thor Card Sur 2012.
Baum C, Seiffert M, Treede H, Reichenspurner H, Deuse T. Concomitant transcatheter aortic valve and left ventricular assist device implantation. ASAIO J. 2013;59:90–2.
• Slaughter MS, Pagani FD, Rogers JG, et al. Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transpl: Off Pub Int Soc Heart Transpl. 2010;29:S1–39. A comprehensive review of continuous flow LVAD implantation technique and management by an assembly of experts.
Rao V, Slater JP, Edwards NM, Naka Y, Oz MC. Surgical management of valvular disease in patients requiring left ventricular assist device support. Ann Thorac Surg. 2001;71:1448–53.
Ahn H, Granfeldt H, Hubbert L, Peterzen B. Long-term left ventricular support in patients with a mechanical aortic valve. Scand Card J: SCJ. 2013;47:236–9.
Krishan K, Pinney S, Anyanwu AC. Successful use of continuous flow ventricular assist device in a patient with mechanical mitral and aortic valve prosthesis without replacement or exclusion of valves. Inter Card Thorac Surg. 2010;10:325–7.
Dranishnikov N, Stepanenko A, Potapov EV, et al. Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience. Int J Art Org. 2012;35:489–94.
Feldman CM, Silver MA, Sobieski MA, Slaughter MS. Management of aortic insufficiency with continuous flow left ventricular assist devices: bioprosthetic valve replacement. J Heart Lung Transpl: Off Pub Int Soc Heart Transpl. 2006;25:1410–2.
Menon AK, Dohmen G, Mahnken AH, Autschbach R. Successful combined procedure of HeartMate II left ventricular assist device implantation and minimally invasive transapical aortic valve replacement. J Thorac Card Surg. 2011;142:708–9.
Park SJ, Liao KK, Segurola R, Madhu KP, Miller LW. Management of aortic insufficiency in patients with left ventricular assist devices: a simple coaptation stitch method (Park's stitch). J Thorac Card Surg. 2004;127:264–6.
Stringham JC, Bull DA, Karwande SV. Patch closure of the aortic anulus in a recipient of a ventricular assist device. J Thorac Card Surg. 2000;119:1293–4.
Adamson RM, Dembitsky WP, Baradarian S, et al. Aortic valve closure associated with HeartMate left ventricular device support: technical considerations and long-term results. J Heart Lung Transpl: Off Pub Int Soc Heart Transpl. 2011;30:576–82.
Aggarwal A, Raghuvir R, Eryazici P, et al. The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients. Annals Thorac Surg. 2013;95:493–8.
Fujita T, Kobayashi J, Hata H, et al. Aortic valve closure for rapidly deteriorated aortic insufficiency after continuous flow left ventricular assist device implantation. J Art Org: Off J Japanese Soc Art Org. 2013;16:98–100.
Martina JR, Schipper ME, de Jonge N, et al. Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device. Inter Card Thorac Surg. 2013;17:616–24.
D'Ancona G, Pasic M, Buz S, et al. TAVI for pure aortic valve insufficiency in a patient with a left ventricular assist device. Annals Thorac Surg. 2012;93:e89–91.
Grohmann J, Blanke P, Benk C, Schlensak C. Trans-catheter closure of the native aortic valve with an Amplatzer Occluder to treat progressive aortic regurgitation after implantation of a left-ventricular assist device. Eur J Cardio-thorac Sur: Off J Eur Assoc Cardio-thorac Surg. 2011;39:e181–3.
Morgan JA, Brewer RJ, Nemeh HW, et al. Left ventricular reverse remodeling with a continuous flow left ventricular assist device measured by left ventricular end-diastolic dimensions and severity of mitral regurgitation. ASAIO J. 2012;58:574–7.
Mohite PN, Zych B, Popov AF, et al. Mitral commissurotomy through the left ventricle apical orifice with Heart Ware left ventricular assist device implantation. J Cardio Thorac Surg. 2013;8:147.
Koelling TM, Aaronson KD, Cody RJ, Bach DS, Armstrong WF. Prognostic significance of mitral regurgitation and tricuspid regurgitation in patients with left ventricular systolic dysfunction. Am Heart J. 2002;144:524–9.
Rogers JH, Bolling SF. The tricuspid valve: current perspective and evolving management of tricuspid regurgitation. Circulation. 2009;119:2718–25.
Rogers JH, Bolling SF. Valve repair for functional tricuspid valve regurgitation: anatomical and surgical considerations. Seminars Thorac Cardiovasc Surg. 2010;22:84–9.
Deo SV, Hasin T, Altarabsheh SE, et al. Concomitant tricuspid valve repair or replacement during left ventricular assist device implant demonstrates comparable outcomes in the long term. J Cardiac Surg. 2012;27:760–6.
Krishan K, Nair A, Pinney S, Adams DH, Anyanwu AC. Liberal use of tricuspid-valve annuloplasty during left-ventricular assist device implantation. Eur J Cardio-thorac Surg: Off J Eur Assoc Cardio-thorac Surg. 2012;41:213–7.
Piacentino 3rd V, Ganapathi AM, Stafford-Smith M, et al. Utility of concomitant tricuspid valve procedures for patients undergoing implantation of a continuous-flow left ventricular device. J Thorac Cardiovasc Surg. 2012;144:1217–21.
Garan AR, Yuzefpolskaya M, Colombo PC, et al. Ventricular arrhythmias and implantable cardioverter-defibrillator therapy in patients with continuous-flow left ventricular assist devices: need for primary prevention? J Am Coll Cardiol. 2013;61:2542–50.
Mulloy DP, Bhamidipati CM, Stone ML, et al. Cryoablation during left ventricular assist device implantation reduces postoperative ventricular tachyarrhythmias. J Thorac Cardiovasc Surg. 2013;145:1207–13.
Cantillon DJ, Tarakji KG, Kumbhani DJ, Smedira NG, Starling RC, Wilkoff BL. Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator. Heart Rhythm: Off J Heart Rhythm Soc. 2010;7:466–71.
Voigt A, Shalaby A, Saba S. Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights. Pacing Clin Electrophysiol: PACE. 2010;33:414–9.
Compliance with Ethics Guidelines
Conflict of Interest
Nikhil Jaik, Robert S. D. Higgins, and Bryan A. Whitson declare that they have no conflict of interest.
Human and Animal Rights and Informed Consent
This article does not contain any studies with human or animal subjects performed by any of the authors.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jaik, N., Higgins, R.S.D. & Whitson, B.A. Simultaneous Procedures During Left Ventricular Assist Device Implantation: Is Less Always More?. Curr Heart Fail Rep 11, 98–102 (2014). https://doi.org/10.1007/s11897-013-0179-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11897-013-0179-z