Skip to main content
Log in

Current and Developing Technologies for BP Monitoring

  • Hypertension (DS Geller and DL Cohen, Section Editors)
  • Published:
Current Cardiology Reports Aims and scope Submit manuscript

Abstract

Purpose of Review

To discuss new and emerging technologies for blood pressure measurement and monitoring, including the limitations of current blood pressure measurement techniques, hopes for new device technologies, and the current barriers impeding change in this space.

Recent Findings

A number of new cuffless devices are being developed and poised to emerge on the marketplace in coming years. There are several different types of technologies and sensors currently under study. New guidelines for validation of cuffless blood pressure devices have recently been developed in anticipation of this change.

Summary

The current standards for blood pressure device validation are specific to cuff-based technology and are insufficient for validating devices with cuffless-based technologies. In anticipation of a number of new cuffless technologies coming to market in the coming years, three sets of standards have been developed and published in recent years to address this gap.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

Papers of particular interest, published recently, have been highlighted as: •  Of importance •• Of major importance

  1. NCD Risk Factor Collaboration (NCD-RisC). Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants. Lancet. 2021;398(10304):957–80. https://doi.org/10.1016/S0140-6736(21)01330-1.

  2. Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation. 2005;111(5):697–716. https://doi.org/10.1161/01.CIR.0000154900.76284.F6.

    Article  PubMed  Google Scholar 

  3. Amoore JN. Oscillometric sphygmomanometers: a critical appraisal of current technology. Blood Press Monit. 2012;17(2):80–8. https://doi.org/10.1097/MBP.0b013e32835026b0.

    Article  PubMed  Google Scholar 

  4. Park SH, Shin JH, Park J, Choi WS. An updated meta-analysis of remote blood pressure monitoring in urban-dwelling patients with hypertension. Int J Environ Res Public Health. 2021;18(20). https://doi.org/10.3390/ijerph182010583.

  5. Kario K, Shimbo D, Tomitani N, Kanegae H, Schwartz JE, Williams B. The first study comparing a wearable watch-type blood pressure monitor with a conventional ambulatory blood pressure monitor on in-office and out-of-office settings. J Clin Hypertens (Greenwich). 2020;22(2):135–41. https://doi.org/10.1111/jch.13799.

    Article  PubMed  Google Scholar 

  6. Mukkamala R, Stergiou GS, Avolio AP. Cuffless blood pressure measurement. Annu Rev Biomed Eng. 2022;24:203–30. https://doi.org/10.1146/annurev-bioeng-110220-014644.

    Article  CAS  PubMed  Google Scholar 

  7. Zhao L, Liang C, Huang Y, Zhou G, Xiao Y, Ji N, et al. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. NPJ Digit Med. 2023;6(1):93. https://doi.org/10.1038/s41746-023-00835-6.

    Article  PubMed  PubMed Central  Google Scholar 

  8. • Stergiou GS, Mukkamala R, Avolio A, Kyriakoulis KG, Mieke S, Murray A, et al. Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. J Hypertens. 2022;40(8):1449–60. https://doi.org/10.1097/HJH.0000000000003224. This is a comprehensive review on cuffless BP devices and the potential benefits and challenges associated with them.

  9. Fortin J, Rogge DE, Fellner C, Flotzinger D, Grond J, Lerche K, et al. A novel art of continuous noninvasive blood pressure measurement. Nat Commun. 2021;12(1):1387. https://doi.org/10.1038/s41467-021-21271-8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, et al. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) collaboration statement. J Hypertens. 2018;36(3):472–8. https://doi.org/10.1097/HJH.0000000000001634.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. IEEE standard for wearable cuffless blood pressure measuring devices. IEEE Std 1708–2014 2014:1–38. https://standards.ieee.org/standard/1708-2014.html. [Accessed 8 August 2023].

  12. IEEE standard for wearable, cuffless blood pressure measuring devices - amendment 1. IEEE Std 1708a-2019 (Amendment to IEEE Std 1708–2014) 2019:1–35. https://standards.ieee.org/standard/1708a-2019.html. [Accessed 8 August 2023].

  13. Non-invasive sphygmomanometers — Part 3: Clinical investigation of continuous automated measurement type. International Organization for Standardization (ISO) 81060–3:2022. https://www.iso.org. [Accessed 8 August 2023].

  14. •• Stergiou GS, Avolio AP, Palatini P, Kyriakoulis KG, Schutte AE, Mieke S, et al. European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. J Hypertens. 2023. https://doi.org/10.1097/HJH.0000000000003483. This publication summarizes the recently published validation standards for cuffless BP devices and puts forth a new set of validation critueria endorsed by the European Society of Hypertension.

  15. • Mukkamala R, Shroff SG, Landry C, Kyriakoulis KG, Avolio AP, Stergiou GS. The Microsoft Research Aurora Project: important findings on cuffless blood pressure measurement. Hypertension. 2023;80(3):534–40. https://doi.org/10.1161/HYPERTENSIONAHA.122.20410. This manuscript outlines the results of the Aurora Study and the implications these findings may have on the wider adoption of cuffless BP devices.

  16. Whelton PK, Carey RM, Aronow WS, Casey DE Jr, Collins KJ, Dennison Himmelfarb C, et al. 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. J Am Coll Cardiol. 2018;71(19):e127–248. https://doi.org/10.1016/j.jacc.2017.11.006.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jeffrey M. Turner.

Ethics declarations

Conflict of Interest

The authors declare that they have no conflict of interest.

Human and Animal Rights and Informed Consent

This article does not contain any studies with human or animal subjects performed by any of the authors.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gunasekaran, D., Turner, J.M. Current and Developing Technologies for BP Monitoring. Curr Cardiol Rep 25, 1151–1156 (2023). https://doi.org/10.1007/s11886-023-01956-w

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11886-023-01956-w

Keywords

Navigation