Skip to main content

Advertisement

Log in

Using indoor plants as biomonitors for detection of toxic metals by tobacco smoke

  • Published:
Air Quality, Atmosphere & Health Aims and scope Submit manuscript

Abstract

Clean air is an indispensable resource for modern world. Many people are indifferent to the seriousness of air pollution or have only recently realized the problem. The air pollution continues deteriorating with several emissions every year on global scale. Beside various sources, tobacco smoke has caused the indoor air pollution. One of the most important of these factors is smoking. Especially indoor air pollution occurs depending on tobacco use. Exposure to cigarette smoke is recognized as the most significant health problem in indoor air. The study aims to evaluate the toxic metal accumulation due to tobacco smoke indoors by using some indoor ornamental plants. In this study, Dieffenbachia amoena, Dracena marginata, Ficus elastica, Spathiphyllum wallisii, and Yucca massengena were used houseplants as biomonitors. Accumulation of some toxic metals can be easily seen in indoor plants. Cadmium (Cd), chrome (Cr), and lead (Pb) were selected that high emissions from tobacco smoke. They were determined by taking the leaves of the plant species and analyzed with inductively coupled plasma-optical emission spectrometry (ICP-OES). The Cd, Cr, and Pb concentrations (Pb > Cr > Cd) were higher with tobacco than non-tobacco in all species. The results showed that Spathiphyllum wallisii was selected to be most suitable as biomonitor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Data availability

All data generated or analyzed during this study are included in this published article.

Not applicable.

References

Download references

Acknowledgements

This study is produced from the MSc thesis titled as “Change of heavy metal concentrations in some indoor plants depends on smoking” conducted at Kastamonu University, Institute of Science, Department of Material Science and Engineering.

Author information

Authors and Affiliations

Authors

Contributions

Wasem Esmael Omer Ghoma: raw material collection, processing analysis, interpretation. Hakan Sevik: thesis supervisor, processing analysis, interpretation. Kaan Isinkaralar: conceptualization, software, writing original draft, data curation, formal analysis and review and editing.

Corresponding author

Correspondence to Kaan Isinkaralar.

Ethics declarations

Ethics approval.

Not applicable.

Consent to participate.

Not applicable.

Consent to publish.

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ghoma, W., Sevik, H. & Isinkaralar, K. Using indoor plants as biomonitors for detection of toxic metals by tobacco smoke. Air Qual Atmos Health 15, 415–424 (2022). https://doi.org/10.1007/s11869-021-01146-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11869-021-01146-z

Keywords

Navigation