Measurement of total volatile organic compound (TVOC) in indoor air using passive solvent extraction method

  • Published:
Air Quality, Atmosphere & Health Aims and scope Submit manuscript

Abstract

The measurement of total volatile organic compound (TVOC) is effective for evaluating indoor air quality. This study aimed to develop a procedure for TVOC measurement using a passive solvent extraction method (SD_passive). The quantitative and qualitative performances of SD_passive for TVOC measurement were compared to those of the active thermal desorption method (TD_active). TVOC concentrations of the SD_passive method were highly correlated with those of the TD_active method. However, below 600 μg/m3, they were slightly underestimated compared to those of the TD_active method. This was because the sampling rates (SRs) of specific volatile organic compounds (VOCs), such as cyclic siloxane and nonanal, which are often detected in indoor air, were lower than those of toluene used for calculating TVOC concentration in the SD_passive method. Therefore, several correction methods using the appropriate SR were explored to obtain TVOC concentrations equivalent to those obtained using the TD_active method. In the proposed method, individual SRs were used for specific VOCs and estimated SRs were used for other VOCs as a function of the total ion chromatogram retention time (Rt) (SR = 96, Rt < 25; SR = − 3.2, Rt + 150, Rt ≧ 25). Consequently, below 600 μg/m3, the SD_passive method could achieve a qualitative performance equivalent to that of the TD_active method. The ten major compounds of TVOC identified using the SD_passive method agreed with those using the TD_active method. Overall, the proposed method is easy to implement, inexpensive, and suitable for rapid evaluation of indoor air quality.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

Download references

Acknowledgements

The authors are grateful to those who cooperated in sampling.

Funding

This work was supported by the Miura Co., Ltd.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takahiro D. Ishizaka.

Ethics declarations

Competing interest

The authors declare that they have no conflict of interest.

Additional information

Highlights

• SD_passive underestimated TVOC concentrations compared to TD_active.

• The proposed correction method uses individual SRs for specific VOCs.

• The correction method estimated SRs as a function of TIC retention time for other VOCs.

• SD_passive is convenient and cost-efficient for evaluating indoor air pollution.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ishizaka, T.D., Kawashima, A., Hishida, N. et al. Measurement of total volatile organic compound (TVOC) in indoor air using passive solvent extraction method. Air Qual Atmos Health 12, 173–187 (2019). https://doi.org/10.1007/s11869-018-0639-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11869-018-0639-4

Keywords

Navigation