Skip to main content
Log in

Incidental detection of haemoglobin (Hb) variants during high performance liquid chromatography (HPLC) analysis of HbA1c: is it time for a standardised approach to reporting?

  • Original Article
  • Published:
Irish Journal of Medical Science (1971 -) Aims and scope Submit manuscript

Abstract

Back ground

Haemoglobin (Hb) variants are genetic variations in the globin genes that code for an abnormal globin protein structure. The prevalence of Hb variants has increased in Ireland due to the number of emigrants from Africa and Southeast Asia. The rate of incidentally detected Hb variants, in laboratories employing HPLC to measure HbA1c, has increased in parallel. The presence of a Hb variant can compromise HbA1c measurement and interpretation. In such cases, HbA1c cannot be used to diagnose diabetes or to assess concordance with glycaemic targets.

Aim

To establish the number of incidentally identified Hb variants during 10 months of routine HbA1c analysis, and the percentage of HbA1c reports alerting the requesting clinician to the presence of a Hb variant.

Methods

The laboratory database was interrogated to extract all records of HbA1c requests and incidentally identified Hb variants from March to December 2012.

Results

A total of 32,636 HbA1c analyses were performed during the evaluation period. Seventy-three Hb variants were identified in a total of 46 patients. In 32.6 % (15 of 46) the haemoglobinopathy status was known prior to testing and 97 % of HbA1c reports communicated the presence of the Hb variant to the requesting clinician.

Conclusion

Hb variants may invalidate the results of HbA1c analysis and could result in a missed diagnosis or a misdiagnosis of diabetes or mismanagement of a patient with diabetes mellitus. It is, therefore, imperative that a comment alerting the requesting clinician to the presence of the Hb variant is appended to the HbA1c result.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Rhea JM, Roberts-Wilson TK, Molinaro RJ ((2012)) Impact of hemoglobin variants on HbA1c interpretation: do we assume too much? MLO Med Lab Obs 44:8–10 (12 passim:quiz 20)

    Google Scholar 

  2. Kohne E (2011) Hemoglobinopathies: clinical manifestations, diagnosis, and treatment. Dtsch Arztebl Int 108:532–540

    PubMed Central  PubMed  Google Scholar 

  3. The diabetes control and complications trial research group ((1993)) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329:977–986

    Article  Google Scholar 

  4. UK prospective diabetes study (UKPDS) group ((1998)) Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet 352:837–853

    Article  Google Scholar 

  5. Sacks DB, Arnold M, Bakris GL et al (2011) Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 34:e61–e99

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  6. WHO (2011) Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus abbreviated report of a WHO consultation. WHO/NMH/CHP/CPM/11.1

  7. Cassidy M, Smith TP, Barrett N, McKenna TJ (2006) Haemoglobinopathies may lead to grossly inaccurate reporting og HbA1c levels. Ir J Med Sci 175:35

    Google Scholar 

  8. Saw S, Loh TP, Yin C, Sethi SK (2013) Identification of hemoglobin variants in samples received for glycated hemoglobin testing. Clin Chim Acta 415:173–175

    Article  CAS  PubMed  Google Scholar 

  9. Wiwanitkit V (2007) Problem of using hemoglobin A1C measurement in endemic area of hemoglobinopathy. Prim Care Diabetes 1:173–175

    Article  PubMed  Google Scholar 

  10. Nasir NM, Thevarajah M, Yean CY (2010) Hemoglobin variants detected by hemoglobin A1c (HbA1c) analysis and the effects on HbA1c measurements. Int J Diabetes Dev Ctries 30:86–90

    Article  PubMed Central  PubMed  Google Scholar 

  11. Little RR, Roberts WL (2009) A review of variant hemoglobins interfering with hemoglobin A1c measurement. J Diabetes Sci Technol 3:446–451

    Article  PubMed Central  PubMed  Google Scholar 

  12. Gunneberg A, Griffin D (2005) Laboratories should spot haemoglobin variants. Diabet Med 22:1779

    Article  CAS  PubMed  Google Scholar 

  13. IEQAS (2013) Recommended minimum report comment

Download references

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. O’Shea.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Reeve, J., Blake, L., Griffin, D. et al. Incidental detection of haemoglobin (Hb) variants during high performance liquid chromatography (HPLC) analysis of HbA1c: is it time for a standardised approach to reporting?. Ir J Med Sci 184, 353–355 (2015). https://doi.org/10.1007/s11845-014-1118-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11845-014-1118-z

Keywords

Navigation