Abstract
Back ground
Haemoglobin (Hb) variants are genetic variations in the globin genes that code for an abnormal globin protein structure. The prevalence of Hb variants has increased in Ireland due to the number of emigrants from Africa and Southeast Asia. The rate of incidentally detected Hb variants, in laboratories employing HPLC to measure HbA1c, has increased in parallel. The presence of a Hb variant can compromise HbA1c measurement and interpretation. In such cases, HbA1c cannot be used to diagnose diabetes or to assess concordance with glycaemic targets.
Aim
To establish the number of incidentally identified Hb variants during 10 months of routine HbA1c analysis, and the percentage of HbA1c reports alerting the requesting clinician to the presence of a Hb variant.
Methods
The laboratory database was interrogated to extract all records of HbA1c requests and incidentally identified Hb variants from March to December 2012.
Results
A total of 32,636 HbA1c analyses were performed during the evaluation period. Seventy-three Hb variants were identified in a total of 46 patients. In 32.6 % (15 of 46) the haemoglobinopathy status was known prior to testing and 97 % of HbA1c reports communicated the presence of the Hb variant to the requesting clinician.
Conclusion
Hb variants may invalidate the results of HbA1c analysis and could result in a missed diagnosis or a misdiagnosis of diabetes or mismanagement of a patient with diabetes mellitus. It is, therefore, imperative that a comment alerting the requesting clinician to the presence of the Hb variant is appended to the HbA1c result.
Similar content being viewed by others
References
Rhea JM, Roberts-Wilson TK, Molinaro RJ ((2012)) Impact of hemoglobin variants on HbA1c interpretation: do we assume too much? MLO Med Lab Obs 44:8–10 (12 passim:quiz 20)
Kohne E (2011) Hemoglobinopathies: clinical manifestations, diagnosis, and treatment. Dtsch Arztebl Int 108:532–540
The diabetes control and complications trial research group ((1993)) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329:977–986
UK prospective diabetes study (UKPDS) group ((1998)) Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet 352:837–853
Sacks DB, Arnold M, Bakris GL et al (2011) Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 34:e61–e99
WHO (2011) Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus abbreviated report of a WHO consultation. WHO/NMH/CHP/CPM/11.1
Cassidy M, Smith TP, Barrett N, McKenna TJ (2006) Haemoglobinopathies may lead to grossly inaccurate reporting og HbA1c levels. Ir J Med Sci 175:35
Saw S, Loh TP, Yin C, Sethi SK (2013) Identification of hemoglobin variants in samples received for glycated hemoglobin testing. Clin Chim Acta 415:173–175
Wiwanitkit V (2007) Problem of using hemoglobin A1C measurement in endemic area of hemoglobinopathy. Prim Care Diabetes 1:173–175
Nasir NM, Thevarajah M, Yean CY (2010) Hemoglobin variants detected by hemoglobin A1c (HbA1c) analysis and the effects on HbA1c measurements. Int J Diabetes Dev Ctries 30:86–90
Little RR, Roberts WL (2009) A review of variant hemoglobins interfering with hemoglobin A1c measurement. J Diabetes Sci Technol 3:446–451
Gunneberg A, Griffin D (2005) Laboratories should spot haemoglobin variants. Diabet Med 22:1779
IEQAS (2013) Recommended minimum report comment
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Reeve, J., Blake, L., Griffin, D. et al. Incidental detection of haemoglobin (Hb) variants during high performance liquid chromatography (HPLC) analysis of HbA1c: is it time for a standardised approach to reporting?. Ir J Med Sci 184, 353–355 (2015). https://doi.org/10.1007/s11845-014-1118-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11845-014-1118-z