Analysis and removal of the stench emitted from indoor dust

  • Environmental Engineering
  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

The offensive odor produced from indoor dust accumulated inside a vacuum cleaner is quite unpleasant to the user. In this study, the odor of dust samples prepared under various conditions was examined using an olfactory method that employs the human sense of smell. In addition, the odorous compounds were analyzed by GC-MS. The odor intensity of the dust collected inside the vacuum cleaner increased in proportion to not only the humidity and temperature of the dust, but also to the cleaning period of the container where indoor dust was accumulated. GC/MS confirmed aldehydes to be the main odorous compounds. The dilution ratio at which the stench of the indoor dust was not detected was determined by using the triangle odor bag method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Korea Ministry of Environment, Regulation and Measurement of Odors, 55 (2005).

  2. ASTM International, Guidelines for the Selection and Training of Sensory Panel Members, STP 758 (1981).

  3. Japan Ministry of the Environment, Measurement Review, 102 (2003).

  4. Korea Ministry of Environment, Regulation and Measurement of Odors, 114 (2005).

  5. P. J. Hobbs, T. H. Misselbrook and B. F. Pain, J. Agric. Eng. Res., 60, 137 (1995).

    Article  Google Scholar 

  6. ASTM International, Standard Method for Measurement of Odor in Atmospheres (Dilution Method), D1391-78 (1978).

  7. J. L. Mills, R. T. Walsh, K. D. Luedtke and L. K, Smith, J. Air Pol. Control Assoc., 13, 467 (1963).

    CAS  Google Scholar 

  8. Y. Chen, D. S. Bundy and S. J. Hoff, J. Air and Waste Man. Assoc., 49, 847 (1999).

    CAS  Google Scholar 

  9. Y. Chen, D. S. Bundy and S. J. Hoff, J. Air and Waste Man. Assoc., 49, 1082 (1999).

    Google Scholar 

  10. A. Dravnieks and F. Jarke, J. Air Pol. Control Assoc., 30, 1284 (1980).

    Google Scholar 

  11. Y. Ishikawa and K. Nishida, J. Odor Res. and Eng., 31, 6 (2000).

    Google Scholar 

  12. I. Iwasaki and T. Ishiguro, Japan Soc. Atmos. Env., 13, 34 (1978).

    Google Scholar 

  13. Y. Nagata and N. Takeuchi, Bulletin of Japan Env. Sanitation Cen., 7, 75 (1980).

    CAS  Google Scholar 

  14. D. Parkinson, T. J. Churchill, L. Wady and J. Pawliszyn, Indoor and Built Env., 18, 257 (2009).

    Article  CAS  Google Scholar 

  15. R. Maus, A. Goppelsroder and H. Umhauer, Atmos. Env., 35, 105 (2000).

    Article  Google Scholar 

  16. S. H. Cho, T. Reponen, D. Bernstein, I. David, R. Olds, L. Rolanda, L. Linda, X. Liu, K. Wilson and G. LeMasters, Sci. Total Env., 31, 371 (2006).

    Google Scholar 

  17. J. E. Amoore and E. Hautala, Appl. Toxicol., 3, 272 (1983).

    Article  CAS  Google Scholar 

  18. T. M. Hellman and F. H. Small, J. Air Pol. Control Assoc., 24, 979 (1974).

    CAS  Google Scholar 

  19. G. Leonardos, D. Kendall, N. Barnard, J. Air Pol. Control Assoc., 19, 91 (1969).

    CAS  Google Scholar 

  20. Y. Nagata and N. Takeuchi, Bulletin of Japan Env. Sanitation Cen., 17, 77 (1990).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Do-Heyoung Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, YH., Jung, H., Changshin, S. et al. Analysis and removal of the stench emitted from indoor dust. Korean J. Chem. Eng. 27, 531–535 (2010). https://doi.org/10.1007/s11814-010-0114-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11814-010-0114-x

Key words

Navigation