Skip to main content
Log in

Flow characteristic and wastewater treatment performance of a pilot-scale airlift oxidation ditch

  • Research Article
  • Published:
Frontiers of Environmental Science & Engineering in China Aims and scope Submit manuscript

Abstract

A pilot-scale airlift oxidation ditch using bubble diffuser and baffle as aerator was operated in a wastewater treatment plant (WWTP) to investigate its flow characteristic and wastewater treatment performance. Compared with the conventional oxidation ditch process, effective depth and oxygen utilization efficiency of this new process was improved by underwater aeration. Furthermore, it had a reversed velocity distribution, which decreased from the bottom to the top on vertical section. Velocity measurement showed that a velocity over 0.2 m/s at the bottom was sufficient to prevent sludge settlement during long term operation. Application of these concepts would save land area and energy consumption by about 25%–50% and 55%, respectively. In this new system, organic biodegradation and nitrification could be well achieved. Denitrification could occur steadily in the straight part by adjusting the airflow rate. An average TN removal rate of 63% was achieved with dissolved oxygen (DO) concentrations between 0.6 mg/L and 1.5 mg/L. The main pollutants in the effluent could meet the strictest discharge standard (COD<50 mg/L, NH4 +−N < 5 mg/L, and TN < 15 mg/L) in China now.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Barnes D, Forster C F, Johnstone D W M. Oxidation Ditches in Wastewater Treatment. London: Pitman Books limited, 1983

    Google Scholar 

  2. Mandt M G, Bell B A. Oxidation Ditches in Wastewater Treatment. Collingwood: Ann Arbor Science Publishers, 1984

    Google Scholar 

  3. US Environmental Protection Agency, Office of Water. EPA 832-F- 00-013 Wastewater Technology Fact Sheet: Oxidation Ditches. 2000

  4. Gillot S, Capela S, Héduit A. Effect of horizontal flow on oxygen transfer in clean water with surfactants. Water Research, 2000, 34(2): 678–683

    Article  CAS  Google Scholar 

  5. Nicolella C, van Loosdrecht M C M, Heijnen J J. Mass transfer and reaction in a biofilm airlift suspension reactor. Chemical Engineering Science, 1998, 53(15): 2743–2753

    Article  CAS  Google Scholar 

  6. Talvy S, Cockx A, Line A. Global modeling of a gas-liquid-solid airlift reactor. Chemical Engineering Science, 2005, 60(22): 5991–6003

    Article  CAS  Google Scholar 

  7. Shi H C, Yin Y M. China Patent. 200510008928.5, 2005

  8. Environmental Protection Agency of Jiangsu Province, China. Discharge standard of main water pollutants for municipal wastewater treatment plant of Taihu area (DB32/1072-2007) (in Chinese)

  9. State Environmental Protection Agency, China. Standard Methods for the Examination of Water and Wastewater. 4th ed. Beijing: Chinese Environmental Science Publishers, 2002 (in Chinese)

    Google Scholar 

  10. Pang H T, Shi H C, Shi H M, Yang C, Yin Y M. Flow characteristic of a pilot scale airlift oxidation ditch. China Environmental Science, 2008, 28(12): 1057–1061 (in Chinese)

    CAS  Google Scholar 

  11. Argaman Y. Single sludge nitrogen removal in an oxidation ditch. Water Research, 1984, 18(1): 493–500

    Article  Google Scholar 

  12. Rittman B E, Langeland W E. Simultaneous denitrification with nitrification in single-channel oxidation ditches. Journal of theWater Pollution Control Federation, 1985, 57(4): 300–308

    Google Scholar 

  13. Liu J X, Groenestijn JW, Doddema H J, Wang B Z. Influence of the aeration brush on nitrogen removal in the oxidation ditch. European Water Pollution Control, 1996, 6: 25–30

    Google Scholar 

  14. Hao X D, Doddema H J, Van Groenestijn J W. Conditions and mechanisms affecting simultaneous nitrification and denitrification in a pasveer oxidation ditch. Bioresource Technology, 1997, 59: 207–215

    Article  CAS  Google Scholar 

  15. Holman J B, Wareham D G. COD, ammonia and dissolved oxygen time profiles in the simultaneous nitrification/denitrification process. Biochemical Engineering Journal, 2005, 22: 125–133

    Article  CAS  Google Scholar 

  16. Pochana K, Keller J. Study of factors affecting simultaneous nitrification and denitrification (SND). Water Science and Technology, 1999, 39(6): 61–68

    Article  CAS  Google Scholar 

  17. Collivignarelli C, Bertanza G. Simultaneous nitrificationdenitrification processes in activated sludge plants performance and applicability. Water Science and Technology, 1999, 40(4–5): 187–194

    Article  CAS  Google Scholar 

  18. Peng Y Z, Hou H X, Wang S Y. Nitrogen and phosphorus removal in pilot-scale anaerobic-anoxic oxidation ditch system. Journal of Environmental Sciences, 2008, 20(4): 398–403

    Article  CAS  Google Scholar 

  19. Liu Y C, Shi H C, Wang Z Q. Variation of dissolved oxygen and optimum control conditions in carrousel oxidation ditch. China Environmental Science, 2008, 28(9): 843–846 (in Chinese)

    CAS  Google Scholar 

  20. Gillot S, Capela S, Heduit A. Effect of horizontal flow on oxygen transfer in clean water with surfactants. Water Research, 2000, 34(2): 678–683

    Article  CAS  Google Scholar 

  21. Gillot S, Heduit A. Effect of air flow rate on oxygen transfer in an oxidation ditch equipped with fine bubble diffusers and slow speed mixers. Water Research, 2000, 34(5): 1756–1762

    Article  CAS  Google Scholar 

  22. Nakasone H, Ozaki M. Oxidation-ditch process using falling water as aerator. Journal of Environmental Engineering, 1995, 121(2): 132–139

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hanchang Shi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pang, H., Shi, H. & Shi, H. Flow characteristic and wastewater treatment performance of a pilot-scale airlift oxidation ditch. Front. Environ. Sci. Eng. China 3, 470–476 (2009). https://doi.org/10.1007/s11783-009-0143-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11783-009-0143-z

Keywords

Navigation