This paper proposed the reclosing method in distribution system with battery energy storage system (BESS) using wavelet transform (WT). The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient. The mother wavelet used is db4 of level 6. The fault clearing is detected using the rapid increase of this value. After the detection of fault clearing, the reclosing is performed. To verify the proposed method, various simulations according to the fault clearing times, fault resistances, and fault lengths are performed using EMTP. The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.

摘要

本文提出了采用小波变换 (WT) 的电池储能 (BESS) 配电网系统重合闸方法。 该方法对负载电流进行小波变换, 然后计算细节系数斜率的绝对值。 使用的母小波是 6 级的 db4。 若该值快速的增加即表明故障已清除。 检测到故障清除后, 执行重合闸。 为了验证所提出的方法是否合适, 使用 EMTP (用于电力系统电磁暂态分析的仿真软件) 根据故障清除时间、 故障阻抗和故障范围进行各种仿真。 仿真结果表明, 利用所提出的细节系数斜率绝对值可以检测出故障清除情况, 从而可以成功实现重合闸。

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. HEO J Y, OH Y S, SEO H C, KIM C H. An adaptive autoreclosure scheme with reference to transient stability for transmission lines [J]. Journal of Electrical Engineering&Technology, 2015, 10(3): 795–803.

    Google Scholar 

  2. RADOJEVIĆ Z M, SHIN JOONG-RIN. New digital algorithm for adaptive reclosing based on the calculation of the faulted phase voltage total harmonic distortion factor [J]. IEEE Trans. Power Delivery, 2007, 22: 37–41.

    Article  Google Scholar 

  3. GOLSHAN M E, GOLBON N. Detecting secondary arc extinction time by analyzing low frequency components of faulted phase voltage or sound phase current waveforms [J]. Electrical Engineering, 2006, 88: 141–148.

    Article  Google Scholar 

  4. TERZIJA V V, RADOJEVIĆ Z M. Numerical algorithm for adaptive autoreclosure and protection of medium- voltage overhead lines [J]. IEEE Transactions on Power Delivery, 2004, 19(2): 554–559.

    Article  Google Scholar 

  5. AHN SANG-PIL, KIM CHUL-HWAN, RAJ K. AGGARWAL, ALLAN T. JOHNS. An alternative approach to adaptive single pole auto-reclosing in high voltage transmission systems based on variable dead time control [J]. IEEE Trans On Power Delivery, 2001, 16(4): 676–686.

    Article  Google Scholar 

  6. MOHAMMAD ASHRAF HOSSAIN SADI, MOHD HASAN ALI. Combined operation of SVC and optimal reclosing of circuit breakers for power system transient stability enhancement [J]. Electric Power Systems Research, 2014; 106: 241–248.

    Article  Google Scholar 

  7. LUO Xun-hua, HUANG Chun, JIANG Ya-qun. Improved digital algorithm for adaptive reclosing for transmission lines with shunt reactors [J]. IET Generation, Transmission & Distribution, 2016, 10(9): 2066–2070.

    Article  Google Scholar 

  8. WANG Xin-pu, YANG Jun, LIU Pei, LIU Wen-qing, YAN Jun, TANG Yu-fei, HE Hai-bo. Online calculation for the optimal reclosing time of transmission lines [J]. Electric Power Components and Systems, 2016, 44(17): 1904–1916.

    Article  Google Scholar 

  9. VOGELSANG J, ROMEIS C, JAEGER J. Real-time adaption of dead time for single-phase autoreclosing [J]. IEEE Transactions on Power Delivery, 2016, 31(4): 1882–1890.

    Article  Google Scholar 

  10. OH Jung-Hwan, KIM Jae-Chul. Feature extraction of fault currents associated with multi-shot reclosing scheme in power distribution system [J]. International Journal of Electrical Power & Energy Systems, 2002, 24(1): 79–85.

    Article  Google Scholar 

  11. PARK Jun-Hee, SEO Hun-Chul, KIM Chul-Hwan, RHEE Sang-Bong. Development of adaptive reclosing scheme using wavelet transform of neutral line current in distribution system [J]. Electric Power Components and Systems, 2016, 44(4): 426–433.

    Article  Google Scholar 

  12. LEE Jae-Won, KIM Won-Ki, OH Yun-Sik, SEO Hun-Chul, JANG Won-Hyeok, KIM Yoon Sang, PARK Chul-Won, KIM Chul-Hwan. Algorithm for fault detection and classification using wavelet singular value decomposition for wide-area protection [J]. Journal of Electrical Engineering & Technology, 2015, 10(3): 729–739.

    Article  Google Scholar 

  13. JIANG F, BO Z Q, YANG Q X. The wavelet transform applied to distinguish between transient and permanent fault [C]// Int Conf Power Syst Technol. Beijing, China. 1998: 1116–1120.

    Google Scholar 

  14. KIM C H, AGGARWAL R K. Wavelet transform in power system. Part I. General introduction to the wavelet transform [J]. IEEE Power Eng J, 2000, 14(2): 81–87

    Article  Google Scholar 

  15. VETTERLI M, HERLEY C. Wavelets and filter banks: Theory and design [J]. IEEE Trans Signal Process, 1992, 40(9): 2207–2232.

    Article  MATH  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sang-Bong Rhee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, KW., Kim, CH., Lee, SH. et al. New reclosing scheme of distribution system for utilization of BESS using wavelet transform. J. Cent. South Univ. 25, 78–83 (2018). https://doi.org/10.1007/s11771-018-3718-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11771-018-3718-7

Key words

关键词

Navigation