Abstract
The joint of clay core-wall and concrete cut-off wall is one of the weakest parts in high earth and rockfill dams. A kind of highly plastic clay is always fixed on the joint to fit the large shear deformation between clay core-wall and concrete cut-off wall, so the hydro-mechanical coupling mechanisms on the joint under high stress, high hydraulic gradient, and large shear deformation are of great importance for the evaluation of dam safety. The hydro-mechanical coupling characteristics of the joint of the highly plastic clay and the concrete cut-off wall in a high earth and rockfill dam in China were studied by using a newly designed soil-structure contact erosion apparatus. The experimental results indicate that: 1) Shear failure on the joint is due to the hydro-mechanical coupling effect of stress and seepage failure. The seepage failure will induce the final shear failure when the ratio of deviatoric stress to confining pressure is within 1.0–1.2; 2) A negative exponential permeability empirical model for the joint denoted by a newly defined principal stress function, which considers the coupling effect of confining pressure and axial pressure on the permeability, is established based on hydro-mechanical coupling experiments. 3) The variation of the settlement before and after seepage failure is very different. The settlement before seepage failure changes very slowly, while it increases significantly after the seepage failure. 4) The stress-strain relationship is of a strain softening type. 5) Flow along the joint still follows Darcian flow rule. The results will provide an important theoretical basis for the further evaluation on the safety of the high earth and rockfill dam.
Similar content being viewed by others
References
US Department of the Interior and State of Idaho. Independent panel to review cause of Teton dam failure. Failure of Teton Dam [R]. 1976.
SEED H B, DUNCAN J M. The failure of Teton Dam [J]. Engineering Geology, 1987, 24(1/2/3/4): 173–205.
POTYONDY J G. Skin friction between various soils and construction material [J]. Geotechnique, 1961, 11(4): 339–353.
CLOUGH G W, DUNCAN J M. Finite element analysis of retaining wall behavior [J]. Journal of the Soil Mechanics and Foundations Division, 1971, 97(12): 1657–1673.
BRANDT J R T. Behavior of soil-concrete interfaces [D]. Edmonton, Canada: University of Alberta, 1985.
GHABOUSSI J, WILSON E L, ISENBERG J. Finite element for rock joints and interfaces [J]. Journal of the Soil Mechanics and Foundations Division, 1973, 99(10): 849–862.
DESAI C S, DRUMN E C, ZAMAN M M. Cyclic testing and modeling of interfaces [J]. Journal of Geotechnical Engineering, 1985, 111(6): 793–815.
FRANTZISKONIS G, DESAI C S. Elastoplastic model with damage for strain softening geomaterials [J]. Acta Mechanica, 1987, 68(3): 151–170.
GOODMAN R E, TAYLOR R L, BREKKE T L. A model for the mechanics of jointed rocks [J]. Journal of Soil Mechanics and Foundation Division, ASCE, 1968, 94: 637–659.
ZIENKIEWICZ O C. Analysis of nonlinear problems in rock mechanics with particular reference to jointed rock systems [C]// Proceedings of the Second International Congress on Rock Mechanics. Belgrade, 1970: 8–14.
SHARMA K G, DESAI C S. Analysis and implementation of thin layer element for interfaces and joints [J]. Journal of Engineering Mechanics, 1992, 118: 2442–2442.
SCHMITZ S, BOLEY C, ZOU Y. Stress dependent erosion in layered soil [C]// First Mediterranean Symposium on Advances in Geomaterials and Structures in Hammamet. Tunesien, 2006: 147–152.
ZOU Y, BOLEY C, WEHR J. On the stress dependent contact erosion in vibro stone columns[C]// International Conference on Scour and Erosion 2010 (ICSE-5). ASCE, 2010: 241–250.
HO C C. The erosion behavior of revetment using geotextile [D]. Joseph Fourier University. Grenoble, France, 2007.
BEGUIN R, GUIDOUX C, FAURE Y H, HO C C. Stability conditions and erosion rates at the contact between two soils, subject to a water flow parallel to the interface [C]// International Workshop on Internal Erosion in Dams and Foundations. St. Petersburg, Russia, 2009: 1–19.
GUIDOUX C, FAURE Y H, BEGUIN R, HO C C. Contact erosion at the interface between granular coarse soil and various base soils under tangential flow condition [J]. Journal of Geotechnical and Geoenvironmental Engineering, 2010, 136(5): 741–750.
BEGUIN R, FAURE Y H, GUIDOUX C, PHILIPPE P. Hydraulic erosion along the interface of different soil layers [C]// Proceedings of the Fifth International Conference on Scour and Erosion (ICSE-5), Scour and Erosion (GSP 210). San Francisco, 2010: 387–396.
MCKIBBON J, MAHDI T F. Experimental investigation into embankment external suffusion [J]. Natural Hazards, 2010, 54(3): 749–763.
RICJARDS K S, REDDY K R. Critical appraisal of piping phenomena in earth dams [J]. Bulletin of Engineering Geology and the Environment, 2007, 66(4): 381–402.
FRANCO G E, BAGTZOGLOU A C. An elastic contact mechanics fracture flow model [C]// 15th ASCE Engineering Mechanics Conference. Columbia University, New York, NY, USA, 2002: 1–7.
WORMAN A, OLAFSDOTTIR R. Erosion in a granular medium interface [J]. Journal of Hydraulic Research, 1992, 30(5): 639–655.
Author information
Authors and Affiliations
Corresponding author
Additional information
Foundation item: Projects(51009053, 51079039) supported by the National Natural Science Foundation of China; Project(20100094120004) supported by the Doctoral Program of Higher Education of China
Rights and permissions
About this article
Cite this article
Luo, Yl., Zhan, Ml., Sheng, Jc. et al. Hydro-mechanical coupling mechanism on joint of clay core-wall and concrete cut-off wall. J. Cent. South Univ. 20, 2578–2585 (2013). https://doi.org/10.1007/s11771-013-1771-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11771-013-1771-9