Fate of Hancock valve in tricuspid position 36 years after implantation

  • Hideki Kitamura
  • Arishige Kimura
  • Yasuhide Okawa
  • Masanobu Maeda
Rapid Communication

Abstract

Mid- to long-term durability of bioprosthesis in tricuspid position is acceptable. However, little is known about more extended long-term structural valve changes of Hancock valve. In present report, we describe Hancock valve images 36 years after implantation.

Keywords

Tricuspid valve Hancock Congenital heart disease 

Notes

Compliance with ethical standards

Conflict of interest

The authors have declared that no conflicts of interest exists. The all authors received no funding for the work.

References

  1. 1.
    Guerra F, Bortolotti U, Thiene G, Milano A, Mazzucco A, Talenti E, et al. Long-term performance of the Hancock porcine bioprosthesis in the tricuspid position. A review of forty-five patients with fourteen-year follow-up. J Thorac Cardiovasc Surg. 1990;99:838–45.PubMedGoogle Scholar
  2. 2.
    Glower DD, White DD, Smith LR, Young WG, Oldham HN, Wolfe WG, et al. In- hospital and long-term outcome after porcine tricuspid valve replacement. J Thorac Cardiovasc Surg. 1995;109:877–83.CrossRefPubMedGoogle Scholar
  3. 3.
    Nakano K, Ishibashi-Ueda H, Kobayashi J, Sasako Y, Yagihara T. Tricuspid valve replacement with bioprostheses: long-term results and cause of valve dysfunction. Ann Thorac Surg. 2001;71:105–9.CrossRefPubMedGoogle Scholar
  4. 4.
    Anselmi A, Ruggieri VG, Harmouche M, Flecher E, Corbineau H, Langanay T, et al. Appraisal of long-term outcomes of tricuspid valve replacement in the current perspective. Ann Thorac Surg. 2016;101:863–71.CrossRefPubMedGoogle Scholar
  5. 5.
    Morimoto N, Matsushima S, Aoki M, Henmi S, Nishioka N, Murakami H, et al. Long-term results of bioprosthetic tricuspid valve replacement: an analysis of 25 years of experience. Gen Thorac Cardiovasc Surg. 2013;61:133–8.CrossRefPubMedGoogle Scholar
  6. 6.
    Oumeiri BE, Eynden FV, Nooten GV. Unusual 30-year durability of Hancock II porcine bioprosthesis in tricuspid position. Int J Surg Case Rep. 2015;8:158–60.CrossRefPubMedCentralGoogle Scholar

Copyright information

© The Japanese Association for Thoracic Surgery 2016

Authors and Affiliations

  1. 1.Department of Cardiovascular SurgeryNagoya Heart CenterNagoyaJapan
  2. 2.Department of Cardiac SurgeryAichi Children’s Health and Medical CenterObuJapan

Personalised recommendations