Abstract
We hereby present our technique for using the self-retaining flexible arm retractor and its attachments for mitral valve exposure. The Aortic Valve Assistant, which was developed for aortic valve exposure, is also very useful for exposure of the inferior wall of the left atrium. Our modified atrial hook provides excellent exposure of the anterior mitral annulus. Extensive dissection and the combined use of the flexible arm and attachments allows us comfortable access for mitral valve operations.
Similar content being viewed by others
References
T Kazui H Osaka H Fujita (2006) ArticleTitleThoracic and cardiovascular surgery in Japan during 2004 Jpn J Thorac Cardiovasc Surg 54 363–86 Occurrence Handle16972646 Occurrence Handle10.1007/s11748-006-0033-2
RL Larbalestier RB Chard LH Cohn (1992) ArticleTitleOptimal approach to the mitral valve: dissection of the interatrial groove Ann Thorac Surg 54 1186–8 Occurrence Handle1449308 Occurrence Handle1:STN:280:DyaK3s%2FotVelug%3D%3D Occurrence Handle10.1016/0003-4975(92)90094-K
R Pifarre S Balderman HJ Sullivan A Montoya M Bakhos (1982) ArticleTitleTechnique to facilitate mitral valve exposure Ann Thorac Surg 3 92–3 Occurrence Handle10.1016/S0003-4975(10)63207-9
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shibata, T., Yasuoka, T., Inoue, K. et al. Exposure of the mitral valve using flexible self-retaining retractors and an atrial hook. Gen Thorac Cardiovasc Surg 55, 440–441 (2007). https://doi.org/10.1007/s11748-007-0151-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11748-007-0151-5