Skip to main content

Advertisement

Log in

Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously

  • CASE REPORT
  • Published:
General Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

We report the case of a 54-year-old woman who, 32 years previously, had undergone replacement of the ascending aorta by the inclusion method with a Starr-Edwards ball valve prosthesis and recently underwent aortic root re-reconstruction by the Bentall method. Routine chest radiography revealed dilatation of the mediastinum, and computed tomography revealed an aneurysm of the ascending aorta. At reoperation, although the cloth covering the cage of the Starr-Edwards ball valve prosthesis appeared worn and some pannus formation was seen, the Starr-Edwards ball valve was functioning normally. The aortic root was replaced with a composite graft that consisted of a 23-mm St. Jude bileaflet prosthesis and a 24-mm Hemashield gold graft. The patient was discharged from the hospital in good condition 25 days after surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A Starr ML Edwards (1961) ArticleTitleMitral replacement: clinical experience with a ball-valve prosthesis Ann Surg 154 726–40 Occurrence Handle13916361 Occurrence Handle10.1097/00000658-196110000-00017 Occurrence Handle1:STN:280:DyaF387gsl2lsA%3D%3D

    Article  PubMed  CAS  Google Scholar 

  2. G Gao Y Wu GL Grunkemeiner AP Furnary A Starr (2004) ArticleTitleForty-year survival with the Starr-Edwards heart valve prosthesis J Heart Valve Dis 13 91–6 Occurrence Handle14765846

    PubMed  Google Scholar 

  3. OL Goedje T Fischlein K Adelhard G Nollert W Klinner B Reichart (1997) ArticleTitleThirty-year results of Starr-Edwards prostheses in the aortic and mitral position Ann Thorac Surg 63 613–9 Occurrence Handle10.1016/S0003-4975(96)00945-9

    Article  Google Scholar 

  4. A Tatsuta Jinkoben A Tatsuta (2001) Shinzo benmakusho no geka Igakushoin Tokyo 420–4

    Google Scholar 

  5. M Shiono Y Sezai A Sezai M Hata M Iida N Negishi (2005) ArticleTitleLong-term results of the cloth-covered Starr-Edwards ball valve Ann Thorac Surg 80 204–9 Occurrence Handle15975368 Occurrence Handle10.1016/j.athoracsur.2005.02.003

    Article  PubMed  Google Scholar 

  6. K Tayama H Akashi E Tayama S Fukunaga T Kawara K Kusuga et al. (2004) ArticleTitleReplacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation Circ J 68 507–8 Occurrence Handle15118298 Occurrence Handle10.1253/circj.68.507

    Article  PubMed  Google Scholar 

  7. M Shiono Y Sezai M Hata M Iida N Negishi Y Sezai (2005) ArticleTitleValve dysfunction of the cloth-covered Starr-Edwards ball valve: analysis of excised valve findings at reoperation Circ J 69 844–9 Occurrence Handle15988111 Occurrence Handle10.1253/circj.69.844

    Article  PubMed  Google Scholar 

  8. Y Shapira MS Feinberg R Hirsch M Nili A Sagie (1997) ArticleTitleEchocardiography can detect cloth cover tears in fully covered Starr-Edwards valves: a long-term clinical and echocardiographic study Am Heart J 134 665–71 Occurrence Handle9351733 Occurrence Handle10.1016/S0002-8703(97)70049-8 Occurrence Handle1:STN:280:DyaK1c%2Fht1Squg%3D%3D

    Article  PubMed  CAS  Google Scholar 

  9. Y Sugawara T Sueda K Orihashi M Watari K Okada O Ishii et al. (2000) ArticleTitleA case of reoperation for a Starr-Edwards ball valve prosthesis implanted in the aortic position 29 years previously (in Japanese with English abstract) Nippon Shinzo Kekkan Geka Gakkai Zasshi (Jpn J Cardiovasc Surg) 29 407–9

    Google Scholar 

  10. T Misumi M Kudo K Koizumi H Kumamaru (2005) ArticleTitleReoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation Jpn J Thorac Cardiovasc Surg 53 165–8 Occurrence Handle15828300 Occurrence Handle10.1007/s11748-005-0026-6

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Daisuke Yotsumoto MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yotsumoto, D., Iguro, Y., Ueno, T. et al. Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously. Gen Thorac Cardiovasc Surg 55, 331–334 (2007). https://doi.org/10.1007/s11748-007-0138-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-007-0138-2

Key words

Navigation