Thrombus originating from frayed distal edge of an aortic stent-graft

  • Case Report
  • Published:
The Japanese Journal of Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

An 87-year-old woman who had undergone a stent-graft repair of a descending aortic aneurysm had additional stent-graft implantation for endoleak. The postoperative course was eventful reflecting her preexisting multiple organ disorder, and despite intensive treatment over a span of 2 months, she died of disseminated intravascular coagulation due to intestinal ischemia. Autopsy revealed a thrombus originating from the frayed distal edge of the graft Although the relation between intestinal ischemia and the thrombus remains to be proven, this is considered a vital finding.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ohki T, Veith FJ, Shaw P, Lipsitz E, Suggs WD, Wain RA, et al. Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: A note of caution based on a 9-year experience. Ann Surg 2001; 234: 323–35.

    Article  PubMed  CAS  Google Scholar 

  2. Gorich J, Kraemer S, Tomczak R, Seifarth H, Merkle E, Sunder-Plassmann L, et al. Thromboembolic complications after endovascular aortic aneurysm repair. J Endovasc Ther 2002; 9: 180–4.

    Article  PubMed  Google Scholar 

  3. Krajcer Z, Gilbert JH, Dougherty K, Mortazavi A, Strickman N. Successful treatment of aortic endograft thrombosis with rheolytic thrombectomy. J Endovasc Ther 2002; 9: 756–64.

    Article  PubMed  Google Scholar 

  4. Dorffner R, Thurnher S, Ploterauer P, Kretschmer G, Lammer J. Treatment of abdominal aortic aneurysms with transfemoral placement of stent-graft: Complications and secondary radiologic intervention. Radiology 1997;204: 79–86.

    PubMed  CAS  Google Scholar 

  5. Wegener M, Gorich J, Kraemer S, Fleiter T, Tomczak R, Scharrer-Pamler R, et al. Thrombus formation in aortic endografts. J Endovasc Ther 2001; 8; 372–9.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Taketani, T., Morota, T., Shibata, K. et al. Thrombus originating from frayed distal edge of an aortic stent-graft. Jpn J Thorac Caridovasc Surg 52, 95–97 (2004). https://doi.org/10.1007/s11748-004-0094-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-004-0094-z

Key words

Navigation