Skip to main content
Log in

Real-time cerebral monitoring using multichannel near-infrared spectroscopy in total arch replacement

  • Published:
The Japanese Journal of Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Multichannel near-infrared spectroscopy (NIRS) could detect change in the regional cerebral oxygenation by following animated pictures of oxy-hemoglobin (OxyHb), deoxy-hemoglobin (DeoxyHb) and total hemoglobin in operations for three surgical cases of thoracic aortic aneurysm with selective cerebral perfusion (SCP). Simultaneously measured jugular venous oxygen saturation (SjO2) showed no change in parallel to OxyHb or DeoxyHb of NIRS. It was concluded that SjO2 represented the entire rather than the local findings of the cerebral oxidative metabolism. Assessment of the intra cranial oxidative metabolism using a multichannel NIRS provided real-time information about the efficacy of SCP, while SjO2 had a comprehensive limited value. The animation enabled the detection of regional hypoperfusion visually and instantly during SCP. This multichannel NIRS was a new real-time monitoring method and was useful to prevent cerebral neurological complication due to hypoperfusion during SCP.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Svensson LG, Crawford ES, Hess KR, Coselli JS, Raskin S, Shenaq SA, et al. Deep hypothermia with circulatory arrest. Determinants of stroke and early mortality in 656 patients. J Thorac Cardiovasc Surg 1993; 106: 19–31.

    PubMed  CAS  Google Scholar 

  2. Coselli JS. Retrograde cerebral perfusion via a superior vena caval cannula for aortic arch aneurysm operations. Ann Thorac Surg 1994; 57: 1668–9.

    Article  PubMed  CAS  Google Scholar 

  3. Griepp RB, Stinson EB, Hollingsworth JF, Buehler D. Prosthetic replacement of the aortic arch. J Thorac Cardiovasc Surg 1975; 70: 1051–63.

    PubMed  CAS  Google Scholar 

  4. Kuwabara M, Nakajima N, Yamamoto F, Fujita T, Takeuchi S, Ando M, et al. Continuous monitoring of blood oxygen saturation of internal jugular vein as an useful indicator for selective cerebral perfusion during aortic arch replacement. J. Thorac Cardiovasc Surg 1992; 103: 355–62.

    PubMed  CAS  Google Scholar 

  5. Konishi I, Takeuchi S, Oikawa Y, Wada Y, Sakauchi N, Ito Y, et al. Development of OMM-2000 Optical Multichannel Monitor. Shimadzu Hyouron 2000; 57: 141–51.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shingu, Y., Myojin, K., Ishibashi, Y. et al. Real-time cerebral monitoring using multichannel near-infrared spectroscopy in total arch replacement. Jpn J Thorac Caridovasc Surg 51, 154–157 (2003). https://doi.org/10.1007/s11748-003-0052-1

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-003-0052-1

Key words

Navigation